Akw SmartCare 30303 Instructions Manual

Advertisement

Quick Links

SmartCare Lever Electric Shower
INSTRUCTIONS
Stock code
8.5 kW - 30303
9.5 kW - 30304
Please read all instructions before installation and leave this document
with the end user for future reference as it contains important warranty information

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartCare 30303 and is the answer not in the manual?

Questions and answers

Summary of Contents for Akw SmartCare 30303

  • Page 1 SmartCare Lever Electric Shower INSTRUCTIONS Stock code 8.5 kW - 30303 9.5 kW - 30304 Please read all instructions before installation and leave this document with the end user for future reference as it contains important warranty information...
  • Page 2: Product Features

    Flexible Installation 6 cable entry points 8 water entry points Dual power blocks for left or right wiring Fitting plate retro-fit footprint Connectivity Wired/wireless connectivity to AKW DigiPumps and P12D shower waste pumps remote on/off remote control General: 01905 823 298 General: 01905 823 298 www.akw-ltd.co.uk www.akw-ltd.co.uk...
  • Page 3: Table Of Contents

    ..................  Functional checks ......................  commissioning ........................   beab care In-service tests ...................   beab care In-service record ..................  Order: 01905 823 299 Order: 01905 823 299 orders.akw-ltd.co.uk orders.akw-ltd.co.uk Technical Support: 01905 560 219 Technical Support: 01905 560 219...
  • Page 4: Safety Information

    AKW does not accept any liability in connection with this information or its use. this information is provided on the condition that the installer determines its suitability for each case.
  • Page 5: Operating Instructions

    When power is applied, the Power Light ring will be dimly lit and the shower is in standby mode. to switch on, press the Power button. the Power Light ring will be brightly lit. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 6: Shower Settings

    Wireless Pump Pairing: this setting will be selected when Leds #1, 2 & 3 are lit. Bluetooth Pairing: this setting will be selected when Leds #1, 2, 3 & 4 are lit. Eco Setting: this setting will be selected when Leds #1, 2, 3, 4 & 5 are lit. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 7 Note: eco setting must not be set to ‘on’ if beab care is selected on the dIP switch (see page 23). Order: 01905 823 299 Order: 01905 823 299 orders.akw-ltd.co.uk orders.akw-ltd.co.uk Technical Support: 01905 560 219 Technical Support: 01905 560 219...
  • Page 8: Troubleshooting

    If the problem persists, note which fault LED is lit or flashing and contact AKW Technical Enquiries (01905 560 219 | tech@akw-ltd.co.uk). General: 01905 823 298...
  • Page 9: Cleaning The Filter

    Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219 Order: 01905 823 299 orders.akw-ltd.co.uk...
  • Page 10: Main Components

    Pipe Inlet entry cut-out cut-out diverter Valve Fixing hole Fixing hole shower hose outlet bottom Pipe Inlet and bottom Pipe Inlet and cable entry cover cable entry cover Inlet Filter General: 01905 823 298 www.akw-ltd.co.uk General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 11: Specifications

    Footprint Width (W2) 218 mm Water Ingress rating IPX4 cable entry Points 6 - top, bottom or rear. Water entry Points 8 - top, bottom, rear or side. accredItatIons & certIFIcatIons Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 12: Installation Requirements

    • block, restrict or connect the water outlet pipe to any parts other than those AKW specifically state for use with this electric shower, as it acts as a vent.
  • Page 13: Disassembly

    If using side pipe entry, cut out the area on to the wall. Leave the corner section to one the two parts shown. side until pipe installation is complete. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219 Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 14: Fitting To Wall - With Fitting Plate

    3 marked holes cables or pipework. drill, insert wall match AKW electric showers within the plugs and screw to wall. stock code range 29010 to 29092. Knock out...
  • Page 15: Fitting To Wall - Without Fitting Plate

    Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219 Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 16: Reassembly - Corner Section

    If using side entry, slide the entry covers in. slide the corner section in to the unit. Fasten the screws holding the corner section. General: 01905 823 298 www.akw-ltd.co.uk General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 17: Reassembly - Front Cover

    Place top of the cover against the shower making sure the retaining clips are in the carefully connect the ribbon cable. correct position and press the bottom of the cover to clip. screw in place. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 18: Plumbing

    Note: If valve is tight when rotating, use a flat head screwdriver under tab to free it. right Inlet move Inlet direction Left Inlet retaining screw Left Inlet right Inlet Water Water Flow Flow General: 01905 823 298 www.akw-ltd.co.uk General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 19 Left or right top inlet. Left or right bottom inlet. rear entry side entry Left or right rear inlet. Left or right side inlet. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219 Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 20: Electrical

    Where shower cubicles are located outside of a bathroom, all socket outlets in the room must be protected by a 30 ma rcd. consult the wiring regulations. It is recommended to use the shortest cable route possible from the consumer unit to the shower. General: 01905 823 298 www.akw-ltd.co.uk General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 21 Left or right side rear cable entry. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219 Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 22: Connecting Waste Pump

    Waste Pump connecting Waste Pump A connection can be made with an AKW DigiPump or P12d waste pump to the shower. the pump automatically responds to the shower when operated and can be connected wirelessly or wired. Wireless Pump Connection a wireless pump connection module is available.
  • Page 23: Temperature & Mode Settings

    5 Minutes If beab care (30 - 41°c range) is selected, the shower will ‘beep’ once when the isolator is switched on. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219 Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 24: Functional Checks

    Leds are functioning. Press the Power button to revert to standby mode. It is important to complete the installation and record the commissioning tests to provide a performance reference point for future tests. General: 01905 823 298 www.akw-ltd.co.uk...
  • Page 25: Commissioning

    4. the outlet water temperature should not exceed the maximum temperature switch setting (see page 23). 5. Record details of test equipment (thermometer, voltmeter, flow meter etc.) used for the measurements. Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 26: Beab Care In-Service Tests

    If no significant changes (e.g. less than 1°C) in outlet water temperatures are recorded between tests, then the next in-service test can be deferred to 24-28 weeks. If there is a significant change then contact AKW Technical Enquiries. General: 01905 823 298...
  • Page 27: Beab Care In-Service Record

    In-service record beab care In-service record Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219 Order: 01905 823 299 orders.akw-ltd.co.uk Technical Support: 01905 560 219...
  • Page 28 If the issue is still Follow us on Social: unresolved, contact AKW Technical Enquiries who will provide further advice and arrange for a maintenance engineer to visit if necessary. none of the foregoing affects your statutory rights.