Siemens SIMATIC IPC RS-545A Operating Instructions Manual
Siemens SIMATIC IPC RS-545A Operating Instructions Manual

Siemens SIMATIC IPC RS-545A Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC RS-545A:
Table of Contents

Advertisement

Quick Links

Server SIMATIC IPC RS-545A
SIMATIC
Industrial PC
Server
SIMATIC IPC RS-545A
Operating Instructions
07/2024
A5E53791735-AA
Preface
Product description
Safety instructions
Unpacking and installing
the device
Connecting the device
Commissioning the device
Operating the device
Expanding and assigning
parameters to the device
Device maintenance and
repair
Technical specifications
Dimension drawings
Standards and approvals
Hardware description
Technical support
Markings and symbols
1
2
3
4
5
6
7
8
9
10
11
A
B
C

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIMATIC IPC RS-545A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siemens SIMATIC IPC RS-545A

  • Page 1 Server SIMATIC IPC RS-545A Preface Product description SIMATIC Safety instructions Unpacking and installing the device Industrial PC Server Connecting the device SIMATIC IPC RS-545A Commissioning the device Operating Instructions Operating the device Expanding and assigning parameters to the device Device maintenance and...
  • Page 2: Qualified Personnel

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    • Service and maintenance of industrial PCs General knowledge in the field automation control engineering is recommended. Range of validity of these operating instructions These operating instructions are valid for all order versions of the SIMATIC IPC RS-545A. History Currently released versions of these operating instructions:...
  • Page 4 Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 5: Table Of Contents

    Safety instructions on transport and storage ............... 40 Safety instructions for assembly ..................42 Safety instructions on ambient and environmental conditions ..........44 Safety instructions for I/O devices ..................46 Safety instructions on device and system extensions ............47 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 6 Monitoring the onboard RAID system with "Intel® Optane™ Memory and Storage Management" ........................76 6.4.3.3 Integrating a new drive into an onboard RAID system ............76 6.4.3.4 Integrating a hot-spare drive into an onboard RAID system ..........79 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 7 Installing a 5.25" drive or 5.25" component ..............114 Installing and removing drives in the device ..............116 7.7.1 Installing a 3.5" drive inside on the side panel of the device ..........116 7.7.2 Install M.2 NVMe SSD ....................... 118 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 8 Technical specifications of the plug connectors for the power supply of graphics cards ..150 9.10 Technical specifications of the telescopic rails ..............150 9.11 Technical specifications of the operating system .............. 151 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 9 Service and support ......................171 Troubleshooting ......................172 B.2.1 Problems with device functions ..................172 B.2.2 Problems when booting the device................... 173 B.2.3 Problems with RAID systems..................... 174 B.2.4 Problems when using expansion cards ................174 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 10 Markings and symbols ........................177 Overview ......................... 177 Symbols for safe use and disposal ..................177 Symbols for operator controls ..................177 Symbols of certificates and approvals ................178 Interface icons ......................... 179 Index ..............................181 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 11: Product Description

    • Supplied in printed form with the device • Link and QR code to the online form for the quality control notification in the SIEMENS After Sales Information System (ASIS) • Operating Instructions of the device • Installation of the device •...
  • Page 12: Product Highlights

    (http://w3.siemens.com/mcms/automatio n/en/industrielle- kommunikation/Seiten/Default.aspx) Product highlights The SIMATIC IPC RS-545A is a high-performance industrial PC in 19" installation format (4 U). It is perfectly suited for high-performance industrial PC applications. Device view Note Depending on the configuration ordered the features and illustrations described in this manual may differ from the features of your device.
  • Page 13 • Access protection for the front removable trays, control elements (power, reset), USB interfaces, dust filter and front fan by means of locked fan cover and lockable front door Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 14: Scope Of Application

    IT applications at the control and cell level for: • Industrial server applications • Process and visualization applications • Quality assurance and monitoring tasks • Measurement, control and rule-based tasks • Data acquisition and management Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 15: External Design Of The Device

    Fan cover on front fan with openings to ventilate the device (locked with front door) ③ System status displays (Page 27) ④ Front door: lockable, protection against unauthorized access ⑤ Lock • Key vertical: open • Key horizontal: closed Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 16 Drive cage (in this case type A); depending on the expansion variant, see: • Drive cage (Page 17) ⑤ Interfaces on the front of the device, see Device ports (Page 21) ⑥ Front fan support Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 17: Drive Cage

    Slot 3 (5.25" slot) for: • 2.5" drive or 3.5" drive in the 5.25" mounting frame with removable tray • 5.25" drive or 5.25" component 5.25" mounting frame with removable tray Cover Cover Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 18 Number of the mounting location (here: Mounting location 0) Lock See also 2.5" drive or 3.5" drive in the 5.25" mounting frame with removable tray (Page 108) Installation options for drives with drive cage type A (Page 99) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 19: Drive Cage Type B

    • 5.25" drive or 5.25" component Cover (if no drive is installed) drive cover (if drive is installed) Cover See also Installation options for drives with drive cage type B (Page 100) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 20: Rear Of The Device

    Connections on the rear of the device (Page 21) ⑧ Power supply unit (power supply unit 550 W in this case, see also: "Connection of power supply unit 700 W (2 modules, each 700 W, redundant) (Page 23)") Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 21: Device Ports

    Sum of the currents on the USB interfaces of the device (including the internal USB interfaces) ≤ 3 A 1.4.4.2 Connections on the rear of the device Note Note the information in "Technical specifications of the connections on the device (Page 148)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 22 Maximum cable length: 3 m; depending on attenuation of the cable and maximum data rate of the connection. Use the original connection technology of the I/O devices to be connected without adapters and without extensions. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 23: Connection Of Power Supply Unit 550 W

    (Page 147)". 1.4.4.3 Connection of power supply unit 550 W Socket for power plug 1.4.4.4 Connection of power supply unit 700 W (2 modules, each 700 W, redundant) Sockets for power plug Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 24: Operator Controls

    Reset button The reset button is for the emergency when the device can no longer be operated. You can find information on the hardware reset under "Switching off the device (Page 66)" Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 25: Alarm Reset Button For Power Supply Unit 700 W (2 Modules, Each 700 W, Redundant)

    Risk of electric shock The on-off switch does not fully disconnect the device from the line voltage. You also need to observe the notes and information under "Switching off the device (Page 66)". On-off switch Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 26: Switching Off The Power Supply Unit 700 W (2 Modules, Each 700 W, Redundant)

    The redundant power supply unit 700 W does not have an on-off switch. To completely disconnect the device from the mains voltage, follow the instructions under "Switching off the device (Page 66)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 27: Status Displays

    Data traffic ⑥ WATCHDOG Watchdog status Not activated (function GREEN Activated currently not Expired available) ⑦ TEMP Temperature status No error Possible causes: • CPU temperature is critical • Device temperature is critical Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 28 It may be possible to detect the defective drive with the RAID software. Information is available at "RAID1 system (Page 70)", "RAID5 system (Page 70)" or "Hot- spare drive in RAID1 or RAID5 systems (Page 71)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 29: Status Displays Of The Lan Ports

    Data transfer active flashing ORANGE • Ready to wake up from S5 mode (Blinking then steady) LED 2 Data transmission • 10 Mbps rate ORANGE • 100 Mbps GREEN • 1000 Mbps Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 30: Status Displays Of Power Supply Unit 700 W (2 Modules, Each 700 W, Redundant)

    • Module failed, no redundancy in effect. See also information in "Alarm reset button for power supply unit 700 W (2 modules, each 700 W, redundant) (Page 25)" for this. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 31: Status Displays On Removable Tray For Drives

    Device is switched on and a drive is installed ② Activity Status of the drive ORANGE • Drive is active • Drive is not active See also Drive cage type A (Page 17) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 32: Internal Construction Of The Device

    Drive cage (here in the example: Drive cage type A or type B) ⑥ Guide rail for long expansion cards ⑦ Motherboard ⑧ Expansion card slots ⑨ Slot brackets (numbering of the slots for expansion cards on the enclosure) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 33: Accessories And Replacement Parts

    Accessories and replacement parts 1.6.1 Hardware accessories Accessories from Siemens are available for your device. These are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall You can find additional information in the online ordering system Industry Mall (https://mall.industry.siemens.com).
  • Page 34 DisplayPort adapter 6ES7648-3AF00-0XA0 • DP to DVI-D adapter Connection of monitors DisplayPort to DVI-D with the following adapters possible to: • integrated graphics interfaces 6ES7648-3AG00-0XA0 • DP to VGA adapter DisplayPort to VGA Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 35 5.25" mounting frame for 5.25" mounting frame for removable tray. A5E35804114 HDD / SSD removable tray You can use a 2.5 "or a 3.5" drive in the removable tray. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 36: Software Accessories

    First select your Region and then navigate to the desired topic area. • Industrial automation technology portfolio: Products & Services (https://www.siemens.com/global/en/products/automation/pc-based.html) Area: "SIMATIC IPC software and accessories". • Portal for software download: "Online Software Delivery Portal (OSD) (https://www.automation.siemens.com/swdl/register/ipc)" Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 37: Safety Instructions

    Touching these areas or components can cause death or serious physical injury. • Disconnect the control cabinet from the power supply before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 38 "Switching off the device (Page 66)". • Do not touch power cables and data transmission cables during a thunderstorm. • Keep sufficient distance from electric cables, distributors, systems, etc. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 39 • Do not short-circuit the battery. • Do not reverse the polarity of the battery. • Do not heat the battery over 100 °C. • Protect the battery from direct sunlight, moisture and condensation. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 40: Safety Instructions On Transport And Storage

    Risk of physical injury The device is heavy and may injure persons and be damaged if it falls. • Use the handles on the front panel of the device to carry and lift the device. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 41 • Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 42: Safety Instructions For Assembly

    There is a risk of overheating and personal injury. Note the following instructions and information under: • "Climatic and mechanical environmental conditions (Page 143)" • "Safety instructions on ambient and environmental conditions (Page 44)" Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 43 Touching these areas or components can cause death or serious physical injury. • Disconnect the control cabinet from the power supply before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 44: Safety Instructions On Ambient And Environmental Conditions

    • When the device is operated in severe environments which are subject to caustic vapors or gases, ensure sufficient clean air is provided. • Clean the enclosure surface with a damp cloth. • Make sure that no water gets inside the device. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 45: High Frequency Radiation

    • Remove radiation sources from the environment of the device. • Switch off radiating devices. • Reduce the radio output of radiating devices. • Read the information on electromagnetic compatibility. • Read the information in the technical specifications. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 46: Safety Instructions For I/O Devices

    • Switch off the affected device and then insert the power plug. • Connect all cables from the system to the device and switch all components of the system to active before starting the measurement. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 47: Safety Instructions On Device And System Extensions

    Contact your technical support team (Page 171) or the point of sale to find out which device and system expansions are suitable for installation. • Note the Information on electromagnetic compatibility (Page 161). Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 48 If you install or exchange system expansions and damage your device, the warranty becomes void. It is therefore essential that you observe the information under "Open the device (Page 87)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 49: Limitation Of Liability

    • UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 50 Safety instructions 2.6 Safety instructions on device and system extensions Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 51: Unpacking And Installing The Device

    You can find information on ordering Microsoft® Windows® operating systems under: Important instructions and manuals for operating the device (Page 11) or Technical specifications of the operating system (Page 151). Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 52: Installed Software

    Printed documents • Quick Install Guide for the device with link and QR code to the online form for quality control (quality control notification) in the SIEMENS After Sales Information System (ASIS) • Product Information "Important notes on your device"...
  • Page 53: Device Identification Data

    The following illustrations are examples. The data of your device may differ from the data in these examples. Nameplate The nameplate is located inside the front door. Example: SIMATIC IPC RS-545A nameplate (the information on the nameplate is device- specific) Identification data of the device ①...
  • Page 54: Mounting The Device

    The device can be installed horizontally in control cabinets and 19" rack systems. When telescopic rails are used for mounting, the device can be withdrawn fully from the cabinet or rack. Note the information in "Technical specifications of the telescopic rails (Page 150)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 55: Installation In The Control Cabinet

    Tower Kit can be ordered as an option, see "Hardware accessories (Page 33)". More information More information can be found in the Quick Install Guide (QIG) that is enclosed with the device. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 56: Securing The Device

    You can find the dimensions for the drill holes under "Dimension drawing for drill holes for telescopic rails (Page 156)". You can find detailed information on the telescopic rails under: "Technical specifications of the telescopic rails (Page 150)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 57: Connecting The Device

    Power supply cables and device plugs must bear the prescribed markings. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 58: Connection Of Equipotential Bonding Line

    • The permissible nominal voltage of the device must match the local mains voltage. • Operate the device only in grounded electricity grids (TN networks in accordance with VDE 0100 Part 100 or IEC 60364-1). • Operation via non-grounded or impedance-grounded grids is prohibited. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 59 5. To prevent unintentional removal of the power plug, secure the power plug on the device. 6. Remove the retaining screw ①. 7. Screw on the power plug latch ② with the fixing screw ①. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 60: Connecting The Power Supply Unit 700 W (2 Modules, Each 700 W, Redundant)

    You can find information on the position of the alarm reset button under "Alarm reset button for power supply unit 700 W (2 modules, each 700 W, redundant) (Page 25)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 61: Connecting I/O Devices

    1. Connect the I/O devices to the respective interfaces. Information on the position of the interfaces is available in "Device ports (Page 21)". 2. Secure the cables (Page 64) with a strain relief. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 62: Connecting Monitors

    Information on the firmware settings can be found in the User Manual (UM) for the motherboard, see "Important instructions and manuals for operating the device (Page 11)". See also Technical specifications of the connections on the device (Page 148) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 63: Connecting The Device To Networks

    Control level. Additional information is available under SIMATIC NET (http://w3.siemens.com/mcms/automation/en/industrielle- kommunikation/Seiten/Default.aspx). The software package and the documentation are not included in the scope of supply. More information You can find additional information on the Internet at: Technical support (https://support.industry.siemens.com) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 64: Securing The Cables

    4. Fasten the cables to the corresponding openings in the strain relief ④ using simple cable ties. Example: Cable fastened to strain relief with cable ties Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 65: Commissioning The Device

    Configure this function in the firmware settings: 1. Select: "Advanced > Power Management > Restore AC after Power Loss". 2. Assign the "Always on" value to the firmware setting "Restore AC after Power Loss". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 66: Switching Off The Device

    • Then pull out the power plug or operate the central AC circuit breaker if installed in a control cabinet. Therefore, when installing the device in a control cabinet, ensure that the AC circuit breaker is easily accessible. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 67: Hardware Reset

    – The device switches off and on again. Information on the position of the buttons is available under "Alarm reset button for power supply unit 700 W (2 modules, each 700 W, redundant) (Page 25)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 68 Commissioning the device 5.3 Switching off the device Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 69: Operating The Device

    To connect additional monitors to the device at the same time (multi-monitoring), you can install a graphics card. You can find information on this here: • Connecting monitors (Page 62) • Installing a graphics card (Page 97) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 70: Drive Configurations

    • You can find information on operating a RAID5 system here: Onboard RAID system (Page 72) Possible drive combinations for a RAID5 system • at least 3 x SATA drives – 2.5" SSD – 3.5" HDD Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 71: Hot-Spare Drive In Raid1 Or Raid5 Systems

    Drives which do not have an operating system installed have not yet been set up when delivered. The drives can be set up with the preinstalled operating system. You have the option of backing up your data to these drives. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 72: Onboard Raid System

    If a faulty M.2 NVMe has been detected, an LED is lit on the motherboard directly next to the connection of the M.2 NVMe SSD. Information about the location of this connection can be found under "Layout of the motherboard (Page 163)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 73: Raid System: Installation Options For Drives

    The subsequent setup of an onboard RAID system is performed in the firmware under "Create Volume". Once the onboard RAID system has been set up, it can be configured with the "Intel® Optane™ Memory and Storage Management" software. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 74 9. Select "RAID Level" and select the entry "RAID1" in the following selection window. A list of available drives is displayed. 10. Select "Select Disks". A list of available drives is displayed. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 75 1. Select "Start" > "Intel® Optane™ Memory and Storage Management". 2. Select the "Manage" tab. You can find information on configuring a RAID system with "Intel® Optane™ Memory and Storage Management" in the documentation or in the help for the software. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 76: Monitoring The Onboard Raid System With "Intel® Optane™ Memory And Storage Management

    You can also configure the onboard RAID system in such a way that the new drive is automatically mounted when the defective drive is replaced. Onboard RAID systems with a hot-spare drive are configured so that the hot-spare drive is automatically integrated in the event of an error. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 77 Configure the mounted drive under "Create Raid Volume". Mount new drive during operation in the onboard RAID system (after an error has occurred) Requirement The system is configured to mount new drives manually (not automatically), see above. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 78 4. From the drive information, select the function "Mark as spare" ③. The drive is mounted to the onboard RAID system and appears in the mounted drives area. See also Data synchronization in the RAID system (Page 79) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 79: Integrating A Hot-Spare Drive Into An Onboard Raid System

    Guide value for the duration of data synchronization: • < 3h at 90% HDD system load In addition, system performance may be limited in the case of a manually started maintenance operation until completion of the maintenance phase. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 80: Monitoring Of The Device

    RAID systems (RAID state) • The following statuses, for example, • The status of an inactive hot swap drive is not are displayed in a RAID system: displayed. "Normal", "OK", "Degraded", error "Rebuild", rebuilding Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 81: Remote Maintenance Of The Device

    The following device requirements must be met for using Intel® Active Management Technology (iAMT): • Processor that supports iAMT technology • Can be connected to the network via LAN port X1P1 (Page 21) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 82: Activate Intel® Amt

    6.6.2.4 Logging onto MEBx (assigning password) Note For information on the firmware settings in the user manual (UM) for the motherboard, see "Important instructions and manuals for operating the device (Page 11)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 83 – A special character . ! @ # $ % ^ & * Note The underscore and blank space are valid password characters but do not increase password complexity. 7. Now configure the Intel® AMT functions in the Options of the MEBx (Page 84). Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 84: Configuring The Amt Functions In The Options Of The Mebx

    4. Assign the "Enabled" value to the firmware setting "Unconfigure ME". 5. Press the button <F4> (Save & Exit Setup) and confirm the subsequent dialog with <Y>. 6. Switch off the device or restart the device. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 85: Disabling Intel® Amt Access To The Firmware/Bios Settings

    Activating the Trusted Platform Module You can find information on activating the Trusted Platform Module in the detailed firmware/BIOS description in "Important instructions and manuals for operating the device (Page 11)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 86: Expanding And Assigning Parameters To The Device

    1. Unplug all connecting cables. 2. Open the front panel. (Page 69) 3. Unscrew the locking screw of the enclosure cover ①. 4. Push the enclosure cover back. 5. Lift up and remove the enclosure cover. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 87: Installing And Removing Expansion Cards

    (Page 47)". • You are familiar with the Information on using expansion cards. (Page 88) • The device is fully disconnected from the mains voltage, see "Switching off the device (Page 66)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 88: Removing Expansion Cards

    2. Hold the bar with the card retainer at both ends and remove it by pulling it upwards. The bar is latched on both ends. 3. Disconnect all cables and the screw of the expansion card that you wish to remove. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 89: Installing And Removing Memory Modules

    Use the modules to expand the memory capacity of your device to a maximum of 128 GB. Depending on the number of memory modules used, these are plugged into defined slots on the motherboard. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 90: Installing Memory Modules

    • You are familiar with the information under "Information on using memory modules (Page 90)". • The device is fully disconnected from the line voltage, see "Switching off the device (Page 66)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 91 The slots of the memory modules are labeled on the motherboard. Procedure 1. Open the device. See the notes under "Open the device (Page 87)". 2. To obtain better access to the memory modules, remove expansion cards (Page 89) if required. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 92 6. To prevent tilting, press evenly on both sides of the memory module ② until the lock audibly engages. 7. Close the device. Display of a changed memory configuration A changed memory allocation is automatically recognized when the device is switched on. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 93: Removing Memory Modules

    The slots of the memory modules are labeled on the motherboard. Procedure 1. Open the device. See the notes under "Open the device (Page 87)". 2. To obtain better access to the memory modules, remove expansion cards (Page 89) if required. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 94: Connecting A Usb Stick To The Internal Interface

    Procedure 1. Open the device. See the notes under "Open the device (Page 87)". 2. Insert the USB stick into the socket of the internal USB interface on the motherboard (Page 163). Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 95 (Page 20)". 5. Slide the bar of the retainer ③ onto the USB stick. 6. Fix the retainer by turning the screw ② on the guide rail. 7. Close the device. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 96: Installing And Removing A Graphics Card

    The technical conditions of the power supply unit must be observed. 2. Check the firmware settings. 3. Configure the function "Multi-monitoring" in the firmware settings of the device. Note the following information. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 97: Removing A Graphics Card

    (Page 11)". Procedure 1. The graphics card is an expansion card. Remove the graphics card. Note the information under "Removing expansion cards (Page 89)". 2. Check the firmware settings. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 98: Installing And Removing Drives In Drive Cages

    Mounting location 3 Drive cage type A: • Mounting location 0 • Mounting location 1 • Mounting location 2 Drive cage type A: • Mounting location 3 1 x internal in the device Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 99: Installation Options For Drives With Drive Cage Type B

    You can install up to five drives in the drive cage type B and on the side panel of the device at the following mounting locations. Note Note the numbering of the mounting locations in the type B drive cage (Page 19). Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 100 Drives in drive cage type B may be exposed to the following maximum vibration loads during operation: • 10 ... 58 Hz: 0.015 mm • 58 Hz to 500 Hz: 2 m/s Vibrations must not exceed 500 Hz. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 101: Drives In The Removable Tray

    When you remove the drive while data is being written to it, you may damage the drive and destroy data. • Only take out the removable tray when the device is switched off. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 102 9. Fold the tray bracket out of the removable tray as far as it will go and slide the removable tray fully into the drive cage. Ensure that the removable tray fits tightly in the drive cage. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 103: Removing A Backplane For Removable Tray

    • You are familiar with the important safety instructions under "Safety instructions on device and system extensions (Page 47)". • The device is fully disconnected from the mains voltage, see "Switching off the device (Page 66)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 104 3. Unlatch the backplane by firmly pressing on the latches ② in the direction of the arrow and simultaneously pressing on the ejector ③. 4. Remove the unlatched backplane ④ from the brackets by turning it upwards and removing it from the drive cage. 5. Close the device. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 105: Installing A Backplane For Removable Tray

    To do this, press the locks ① of the cover ② together inside the device and keep them pressed. Then push the locks to the front in the direction of the arrow. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 106 5. Remove all existing removable trays until the drive cage is freely accessible. 6. At the appropriate position, insert the backplane ④ from the front into the drive cage and snap it into place at the back. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 107: Drives In 5.25" Slots Of Drive Cages

    • Installation options for drives with drive cage type A (Page 99) Only use original spare parts or components approved for this device. You can find information on this under "Hardware accessories (Page 33)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 108 – Press on the surfaces ① on the two side mounting bars ② of the 5.25" component. – Press and hold surface ① to push the 5.25" component forward out of the drive holder ④. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 109 8. Make sure that the removable tray is firmly seated in the 5.25" mounting frame. 9. Close the tray bracket. 10. Lock the removable tray with the key. 11. Close the device. 12. Connect the power supply. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 110: Changing A 2.5" Or Drive 3.5" Drive In The Assembly Kit For A 5.25" Tray

    • When replacing a 2.5" SSD: Screwdriver TORX T8 Procedure 1. Open the device. See the notes under "Open the device (Page 87)". 2. Remove all power supply and data cables from the drive. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 111 5. Remove the left and right drive mounting bars ② and the drive cover ③ from the drive. Note: The drive cover is labeled "L" ④ and "TOP" ⑤. The drive mounting bars are labeled "L" and "R" respectively. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 112 9. Attach the left and right drive mounting bars ② on the drive bay ⑥. 10. Slide the drive bay evenly and without tilting 3/4 (not completely) into the guide rail of the drive cage. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 113: Installing A 5.25" Drive Or 5.25" Component

    • You are familiar with the important safety instructions under "Safety instructions on device and system extensions (Page 47)". • The device is fully disconnected from the mains voltage, see "Switching off the device (Page 66)". • Screwdriver TORX T10 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 114 5. Slide the new drive with the drive mounting bars evenly backwards into the guide rails of the drive cage and without tilting, until it clicks into place. 6. Close the device. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 115: Installing And Removing Drives In The Device

    1. Open the device. See the notes under "Open the device (Page 87)". 2. Screw the drive to the drive bay plate (available as option, not included in scope of delivery) at the marked holes. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 116 ③. 4. Connect the SATA cables to the SATA connectors of the motherboard (Page 163) and to the drive ③. 5. Close the device. 6. Connect the power supply unit. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 117: Install M.2 Nvme Ssd

    3. Insert the M.2 NVMe SSD ③ into the slot ① slightly inclined from above parallel to the motherboard. 4. Carefully press down M.2 NVMe SSD. 5. Fix the end of the M.2 NVMe SSD to the motherboard with a screw. 6. Close the device. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 118: Device Maintenance And Repair

    Component Replacement interval Drives 3 years Backup battery 5 years 3 years Filter mat of the fan (front fan) Depending on the degree of soiling Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 119: Removing And Installing Hardware

    2. Remove the filter mat from the fan cover. 3. Insert the new filter mat loosely into the fan cover. Place the filter mat evenly in the fan cover. 4. Replace the fan cover. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 120: Changing The Front Fan

    3. Lift the fan support slightly upwards and remove it to the front from the front of the enclosure. 4. Put down the fan support with the openings facing down (fan is above). Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 121 7. Release the locking latches ④ on the fan support at the rear and front in turn and remove the fan from the fan support. 8. Loosen the locking latches ⑤ of the holder for the adapter plugs ⑥ and remove the holder. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 122: Change The Fan On Drive Cage Type A

    • The device is fully disconnected from the line voltage, see "Switching off the device (Page 66)". • There is no 5.25" component in the corresponding mounting location, see information under "Installation options for drives with drive cage type A (Page 99)". • Screwdriver TORX T10 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 123 – At the top with "Top" – At the bottom with arrows which indicate the direction of rotation and air flow of the fan. 4. Put down the fan support as shown. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 124: Changing The Backup Battery

    • The device is fully disconnected from the mains voltage, see "Switching off the device (Page 66)". Procedure 1. Open the device. See the notes under "Open the device (Page 87)". 2. Remove the expansion cards, if necessary, see "Removing expansion cards (Page 89)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 125: Replacing Power Supply Units

    • You are familiar with the important safety instructions under "Safety instructions on device and system extensions (Page 47)". • The device is fully disconnected from the mains voltage, see "Switching off the device (Page 66)". • Screwdriver TORX T10 • Diagonal cutter Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 126 9. Secure the power supply unit cables in the device again using cable ties. 10. Close the device. 11. Check the safe state of the device. 12. Switch on the power supply unit. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 127: Replacing The Module Of The Redundant Power Supply Unit 700 W

    • You know the important safety instructions under "Safety instructions on device and system extensions (Page 47)". • The device is fully disconnected from the line voltage, see "Switching off the device (Page 66)". • Screwdriver TORX T10 • Diagonal cutter Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 128: Replacing The Processor

    This leads to data loss. • Operate the processor only at a clock frequency that is equal to or less than the permitted clock frequency. • You should therefore only install an approved processor. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 129 The contact springs ③ of the processor socket ② are very sensitive. Take care not to damage these contact springs both when removing and inserting the processor. Always touch the contact springs with the contact side of the processor only flat. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 130: Replacing The Motherboard

    "Important instructions and manuals for operating the device (Page 11)". • The device is fully disconnected from the line voltage, see "Switching off the device (Page 66)". • Screwdriver TORX T10 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 131: Installing The Operating System, Software, And Driver

    For information on restoring the operating system you ordered with the device in the detailed description of the operating system, see "Important instructions and manuals for operating the device (Page 11)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 132: Installing A New Microsoft® Windows® Operating System

    The following methods can be used to obtain a bootable USB flash drive containing these files: – You have ordered a bootable USB flash drive to accompany the delivery of the device. – You create this bootable USB flash drive yourself. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 133: Configuring Firmware/Bios

    You can find information on this in the User Manual (UM) for the motherboard. Note If your device no longer boots, for example, after operating system crash during a firmware update, contact your local SIEMENS contact person. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 134: Recycling And Disposal

    Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device, and dispose of it according to the relevant regulations in your country. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 135 Device maintenance and repair 8.6 Recycling and disposal Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 136: Technical Specifications

    Power supply unit 550 W: • Continuous current at 100 V: ≤ 8 A • Continuous current at 230 V: ≤ 4 A • At startup ≤ 80 A for 3.6 ms Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 137 +5 V/20 A, +3.3 V/20 A; 130 W are permitted in total • +12 V /58.3 A • -12 V/0.5 A; +5 V /3 A The total output of all voltages is max. 700 W. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 138: Current And Power Consumption And Power Supply Unit

    (typical values) M.2 NVMe SSD 2.24 A Internal fan 0.25 A Individual currents, max. permissible, 25 A 22 A 26 A 15 A 0.1 A 2.0 A Power supply unit 550 W Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 139 The requirements of the expansion card for the temperature of the intake air (inside the device) must be observed. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 140: Technical Specifications Of The 550 W Power Supply Unit

    ± 5% +5 V +5%, -3% The total output of the +5 V and +3.3 V voltage must be ≤ 150 W. The total output of all voltages is max. 550 W. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 141: Technical Specifications Of The 700 W Power Supply Unit (2 Modules, Each 700 W, Redundant)

    80% AM to IEC 61000-4-3 • 10 V; 10 kHz up to 80 MHz 80% AM to IEC 61000-4-6 Immunity to magnetic fields 30 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 142: Climatic And Mechanical Environmental Conditions

    The device must be free of any mechanical faults when disk drives are installed in the removable trays. See also Installation options for drives with drive cage type A (Page 99) Installation options for drives with drive cage type B (Page 100) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 143: Technical Specifications Of The Drives

    Intel PCH with Intel Rapid Storage Technology ® ® Slots for memory modules 4 x DIMM sockets for DDR5 4400 MHz, expandable to 128 GB Main memory 8 to 128 GB, DDR5 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 144: Technical Specifications Of The Expansion Card Slots

    • 3.3 V; 3 A • Gen. 4 • 12 V; 5.5 A • Active lanes: 8 • 3.3 V ; 0.4 A Power loss of the slot, permitted: ≤ 75 W Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 145 12 V; 0.5 A • PCI bus primary • 12 V; 0.05 A • 3.3 Vaux; 0.2 A PCIe-Bus CPU PCIe-Bus PCH Note In sum, the current for 3.3 V must not exceed 1.2 A. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 146: Technical Specifications Of Graphic

    DVI: 1920 × 1200 at 60 Hz; 32-bit color depth • DisplayPort: 4096 × 2304 at 60 Hz; 32-bit color depth • VGA (via DP-VGA adapter): 2560 × 1600 at 60 Hz; 32-bit color depth Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 147: Technical Specifications Of The Connections

    24-pin (5 V; 500 mA) USB Type A USB Type A: • High-current USB Type C USB Type C: • High-current 5 V; 1.5 A; up to 10 Gbps Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 148 Realtek ALC887, 8-channel DAC support – Line IN (light blue) – Headphone OUT (pastel green) 1: Ground (max. 2 W at 4 Ω) 2: Audio links – Microphone IN (pink) 3: Audio right Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 149: Technical Specifications Of The Telescopic Rails

    M5 x 6 mm The mounting screws of the telescopic rails may not protrude by more than 5 mm into the enclosure. See also Dimension drawing for drill holes for telescopic rails (Page 156) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 150: Technical Specifications Of The Operating System

    Size File system First Boot 260 MB FAT32 Second 128 MB None Third System 160 GB NTFS, not compressed Fourth WinRE 500 MB NTFS, not compressed Fifth Data Remainder NTFS, not compressed Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 151 Technical specifications 9.11 Technical specifications of the operating system Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 152: Dimension Drawings

    Dimension drawings 10.1 Dimension drawing of the device Note IEC60297_3_100 The system meets the requirements for 4 U according to IEC60297_3_100. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 153: Dimension Drawing Of The Tower Kit

    Dimension drawings 10.2 Dimension drawing of the Tower Kit 10.2 Dimension drawing of the Tower Kit Front view and top view All dimensions in mm. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 154: Dimension Drawing Of The Expansion Cards

    • Device with extender: 339 mm ② Height of the expansion card PCI: 106.7 mm (free space via expansion card: 38.3 mm) PCIe: 111.2 mm (free space via expansion card: 33.8 mm) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 155: Dimension Drawing For Drill Holes For Telescopic Rails

    800 mm cabinet; TS 3659.191 Dimensions of Heitec telescopic rails • for 600 mm cabinet; RP 3659.181 • for 800 mm cabinet; RP 3659.191 ② Dimensions of Schroff telescopic rails; Type 20110-072 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 156 Dimension drawings 10.4 Dimension drawing for drill holes for telescopic rails Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 157: Standards And Approvals

    Certificates and approvals 11.1.1 ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 158: Fcc Rules (Usa)

    This product meets the requirements of EN 61000-6-3 Generic standards - Emission standard for residential, commercial and light-industrial environments. This product meets the requirements of the standard EN 61000-6-3 Generic standards - Emission standard for residential, commercial and light-industrial environments. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 159: Eurasion Customs Union Eac

    Industrial area EN 61000-6-4 EN 61000-6-2 Residential and commercial areas and small EN 61000-6-3 EN 61000-6-1 businesses The devices are compliant with EN 61000-3-2 (harmonic currents) and EN 61000-3-3 (voltage fluctuations and flicker). Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 160: Low-Voltage Guideline

    Electronic Equipment" (RoHS Directive). 11.2.5 Ecodesign directive 2009/125/EC "Directive of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products." Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 161: Hardware Description

    Sum of the currents on the USB ports of the device (including the internal USB ports) ≤ 3 A Technical features of the motherboard Technical features of the motherboard can be found under "General technical specifications of the motherboard (Page 144)". Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 162: Expansion Cards

    PIRQ C PIRQ C PIRQ C INT D PIRQ D PIRQ A PIRQ D PIRQ D PIRQ D PIRQ D PIRQ D PIRQ D PIRQ D Organizational Pins Request REQ0 Grant GNT0 AD16 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 163: Exclusive Pci Hardware Interrupt

    The table describes the assigned I/O addresses in the delivery state of the device. I/O address (hex) Size(bytes) Description of the basic function from 0000 0000 0000 0CF7 PCI Express Root Complex Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 164 0000 00B3 Motherboard resources 0000 00B4 0000 00B5 Programmable Interrupt Controller 0000 00B8 0000 00B9 Programmable Interrupt Controller 0000 00BC 0000 00BD Programmable Interrupt Controller 0000 02E8 0000 02EF Communications Port (COM4) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 165: Interrupt Assignments

    Host PCI IRQ G H 1 Line Function System timer Fixed Communication Fixed s Port (COM1) Communication Fixed s Port (COM2) Communication Fixed s Port (COM3) Communication Fixed s Port (COM4) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 166: Memory Address Assignments

    Trusted Platform Module 2.0 FED4 5000 FED8 FFFF Motherboard resources FED9 0000 FED9 3FFF Motherboard resources FEDA 0000 FEDA 0FFF Motherboard resources FEDA1000 FEDA1FFF Motherboard resources FEDC 0000 FEDC 7FFF Motherboard resources Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 167: Assignment Of Expansion Interfaces To The Software In The Tia Portal (Cp Assignment)

    TIA Portal. Slot Designation on the motherboard TIA Portal Number on the enclosure PCIE4X16_1 X100 PCIE3_X8_1 X101 PCIE4X16_2 X102 PCIE3_X4_1 X103 PCIE4_X4_1 X104 PCIE_X4_2 X105 PCI1 X106 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 168 Hardware description A.4 Assignment of expansion interfaces to the software in the TIA Portal (CP assignment) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 169: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (https://www.siemens.com/supportrequest) • After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
  • Page 170: Troubleshooting

    Time and/or date of the PC is 1. Open the firmware configuration menu. To do not correct this, press the <F2> key during the boot operation. 2. Set the date and the time in the "Main" tab. Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 171: Problems When Booting The Device

    You can find the files and descriptions needed for GPT data storage medium is this on the supplied data storage medium. aborted with the following error message: "Status: 0xc0000225 Info: The boot selection failed because a required device is inaccessible" Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 172: Problems With Raid Systems

    Different pin assignment expansion card and restart the device. If the error no longer occurs, the expansion card was the cause of the fault. Replace this with a Siemens expansion card or contact the supplier of the expansion card. If the device still crashes, contact your technical support team.
  • Page 173 Remove the installed expansion card and reinsert is integrated. connector Examples: • Clean the contact surface of the expansion card • The operating system does with pure ethanol. not boot. • The expansion card is not detected Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 174 Technical support B.2 Troubleshooting Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 175: Markings And Symbols

    Attention ESD (Electrostatic sensitive Warning of hot surface device) Disposal information, observe the local regulations. Symbols for operator controls Symbol Meaning Symbol Meaning On-off switch, without electrical isolation On-off button, without electrical isolation Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 176: Symbols Of Certificates And Approvals

    Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters Approval for United Kingdom Laboratories Approval for India Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 177: Interface Icons

    Connection for functional grounding Line Out (Equipotential-bonding cable) DisplayPort interface Microphone input DVI port LAN interface, not approved for connecting WAN or telephone Serial port USB 2.0 high-speed port USB 3.0 Gen 1 SuperSpeed port Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 178 Markings and symbols C.5 Interface icons Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 179: Index

    ICES compliance, 160 Drive bay plate CE marking, 161 for installing drives on the side panel of the device, 116 Drive cage type A, 17 Installation options for drives, 99 possible drive configurations, 100 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 180 Specification, 145 Graphics memory, 147 Hardware interrupt Fan on type A drive holder, 123 Assigning, 165 Front fan, 15 Hardware reset, 67 Maintenance interval, 119 High frequency radiation Immunity to interference, 45 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 181 Installing the internal drive on the side panel of the device, 116 Manuals, 11 M.2 NVMe SSD, 118 MEBx Integrated graphics interfaces Options, 84 Technical specifications, 147 Memory addresses Assignment, 168 Intel(R) ME Password, 83 Intel® Active Management Technology, 81 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 182 Power supply unit 550 W, 25 RAID system Open Problem with RAID system, 174 Device, 87 Problems with booting, 173 Open the device, 87 RAID1 system, 70 Operating a RAID system, (see: Onboard RAID system) Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 183 Installed on delivery, 52 FCC Rules, 160 Spare parts, 33 USB connection sockets Spare parts services, 35 at the front of the device, 21 On the rear of the device, 21 User Manuals, 11 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...
  • Page 184 Index Ventilation slits, 45 Vibration damping for drives, 19 Vibration exposure for drives in drive cage type B, 101 vibration-damped drive cage, 19 Warranty, 47 Server SIMATIC IPC RS-545A Operating Instructions, 07/2024, A5E53791735-AA...

Table of Contents