Download Print this page
Siemens SIMATIC IPC RW-543B Operating Instructions Manual
Siemens SIMATIC IPC RW-543B Operating Instructions Manual

Siemens SIMATIC IPC RW-543B Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC RW-543B:

Advertisement

Quick Links

SIMATIC IPC RW-543B
SIMATIC
Industrial PC
SIMATIC IPC RW-543B
Operating Instructions
01/2025
A5E54139074-AA
Preface
Product description
Safety instructions
Installing and connecting
the device
Commissioning the device
Operating the device
Expanding and assigning
parameters to the device
Device maintenance and
repair
Technical specifications
Dimension drawings
Standards and approvals
Hardware description
Technical support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
8
9
10
11
A
B
C

Advertisement

loading
Need help?

Need help?

Do you have a question about the SIMATIC IPC RW-543B and is the answer not in the manual?

Questions and answers

Summary of Contents for Siemens SIMATIC IPC RW-543B

  • Page 1 SIMATIC IPC RW-543B Preface Product description SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC RW-543B Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    These operating instructions are valid for all supplied versions of the SIMATIC IPC RW-543B. Conventions The terms "PC" and "device" are sometimes used to refer to the SIMATIC IPC RW-543B in this documentation. Instead of the specific names of the operating system, we are using the abbreviation "Windows 10"...
  • Page 4: Table Of Contents

    3.1.2 Checking the delivery package ................... 32 3.1.3 Device identification data ....................32 Mounting the device ......................34 3.2.1 Mounting types ......................... 34 3.2.2 Securing device ......................... 35 Connecting the device ....................... 36 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 5 Repair information ......................62 Maintenance intervals ......................62 Removing and installing hardware ..................63 7.3.1 Replacing the filter ......................63 7.3.2 Replacing the device fan ....................65 7.3.3 Changing the backup battery ..................... 67 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 6 Layout of the motherboard ....................98 11.1.2 Position of the interfaces on the motherboard ..............99 11.2 External interfaces ......................100 11.2.1 External interfaces ......................100 11.2.2 Serial interface ........................ 101 Technical support ..........................103 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 7 Problems when using expansion cards ................106 Markings and symbols ........................107 Overview ......................... 107 Safety ..........................107 Operator controls......................107 Certificates, approvals and markings ................108 Interfaces ........................109 List of abbreviations .......................... 110 Index ..............................112 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 8: Product Description

    User Manual (UM) for Information on: • Online at: User Manual Mother- the motherboard board SMART3000V5-Q670 • Firmware/BIOS description (https://support.industry.siemens. • Description of the motherboard com/cs/ww/en/view/109978327) • Description of the interfaces on the motherboard SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 9: Product Highlights

    Product highlights The SIMATIC IPC RW-543B is an industrial PC in 19" rack format design (4U). It is perfectly suited for PC applications with high-level industry functionality. SIMATIC IPC RW-543B is available with two enclosure types: Standard enclosure or Eco enclosure.
  • Page 10: Scope Of Application

    Note The supplied device may differ in some details from the figures contained in this manual. Within some of the figures, one device is used to represent all devices. SIMATIC IPC RW-543B configuration plan Device Type Standard enclosure Eco enclosure Type 19"...
  • Page 11: External Design Of The Device

    USB 2.0 port (X68-2) ② Lock ⑦ USB 2.0 port (X68-1) ③ On/off button ⑧ HDD status LED ④ Drive bays 3 x 5.25" ⑨ Power status LED ⑤ Front right door Eco enclosure SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 12: Rear Of The Device

    Standard enclosure ① Power supply ② Function earth ③ Air outlet ④ Interfaces ⑤ Extensible interface ⑥ Expansion slots for: • 2 × PCI • 3 × PCIe x4 • 2 × PCIe x16 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 13 Eco enclosure ① Power supply ② Function earth ③ Air outlet ④ Interfaces ⑤ Extensible interface ⑥ Expansion slots for: • 2 × PCI • 3 × PCIe x4 • 2 × PCIe x16 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 14: Drive Cage

    Mounting location for 3.5" or 2.5" drive in a shock- proof/vibration-proof fixture or for 5.25" drive or components Cover (if no drive is installed) drive cover (if drive is installed) Front right door SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 15: Additional Information

    Technical notes and information on the rated conditions are available in the section Installation options for drive (Page 59). 1.4.4 Interfaces and connections 1.4.4.1 Interfaces Note You can find the detailed information on interfaces under "External interfaces (Page 100)". SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 16: Power Supply Connections

    HDMI (X72) 1 × HDMI Type-A connector ⑩ DPP (X71) 1 × DisplayPort connector 1.4.4.2 Power supply connections The following figures show the power supply connector. 350 W and 500 W 850 W SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 17: Operator Controls

    350 W and 500 W 850 W ① On/Off switch On/Off button Note The on/off button is only effective when the power supply is switched on via the on/off switch at the rear of the device. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 18 Perform a hardware reset only in the case of an emergency. Close all running programs. Make sure that there is no more read or write access to drives and I/O before performing the hardware reset. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 19: Status Displays

    LED 1 (Activity/Link LED) No link Green Linked Green (Blinking) Data activity Green (Blinking then Ready to wake up from S5 mode steady) LED 2 (Speed LED) 10Mbps/100Mbps connection Orange 1 Gbps connection SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 20: Internal Construction Of The Device

    Power supply ② Heat sink of the processor ③ Memory slots ④ Drive cage ⑤ Motherboard ⑥ Slots for expansion cards ⑦ Card holder for expansion cards ⑧ Slots reserved for expansion cards SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 21: Safety Instructions

    Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to...
  • Page 22 • Disconnect the device from the power supply in good time when a thunderstorm is approaching. • Do not touch power cables and data transmission cables during a thunderstorm. • Keep sufficient distance from electric cables, distributors and systems. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 23: Disclaimer For Third-Party Software Updates

    Take corresponding precaution measures before you open the device. Disclaimer for third-party software updates This product includes third-party software. Siemens AG only provides a warranty for updates/patches of the third-party software, if these have been distributed as part of a Siemens software update service contract or officially released by Siemens AG.
  • Page 24: Note On Transport And Storage

    • Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 25: Notes On Mounting

    If the following conditions are not met when installing the system, the IEC/EN/UL 62368-1 approvals are voided and there is a risk of overheating and personal injury. • You should observe the following information on ambient and environmental conditions. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 26 • Ensure that there is a distance of at least 50 mm at the back of the device, depending on wiring. • The device conforms to IP 20 degree of protection. Ensure that there is no splash water in the installation area. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 27: High Frequency Radiation

    Regenerative feedback of voltage to ground by a connected or installed component can damage the device. Connected or built-in I/Os, for example, a USB drive, are not permitted to supply any voltage to the device. Regenerative feedback is generally not permitted. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 28: Notes On Device And System Extensions

    • Only install device or system expansions designed for this device. • Observe the information on "Electromagnetic compatibility" provided in the technical specifications. WARNING 火災危險和電擊危險 通/斷開關沒有將設備從電網斷開。在違規打開或設備損壞時,會出現電擊危險。如果設備或 連接線受損,則會進一步出現火災危險。 请如下保护自身和设备安全: • 在不使用設備時或設備損壞時,始終拨出電源插頭。電源插頭必須便于接觸。 • 將設備與安全引線正確相連。 • 爲機櫃中的裝配使用集中式的電源隔離開關。 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 29 運行條件下使用設備。 • 僅使用適當的清潔劑。注意互聯網中的耐化性提示信息 (參見操作說明,“服務和支持”章 節 SIMATIC PC/PG 系統售後信息)。 WARNING 爲避免電磁干擾, 本產品不應安裝或使用於住宅環境。 Contact your technical support team or the point of sale to find out which device and system expansions are suitable for installation. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 30: Limitation Of Liability

    • UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 31: Installing And Connecting The Device

    • Software and tools to recover your ordered Microsoft® Windows® operating system • Device drivers for installation in operating systems • SIMATIC IPC RW-543B Quick Install Guide • SIMATIC IPC RW-543B Operating Instructions • Operating instructions for your ordered Microsoft® Windows® operating system on this device •...
  • Page 32: Checking The Delivery Package

    The device can be clearly identified with the help of this identification data in case of repairs or loss. The following illustrations are examples. The data of your device may differ from the data in these examples. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 33: Product Label

    Installing and connecting the device 3.1 Preparing for mounting Product label The following image shows the product label on the SIMATIC IPC RW-543B as an example. Identification data of the device ① QR code for information about the device ②...
  • Page 34: Mounting The Device

    • The minimum distance between the device and the housing is 10 cm on the air output end. • Ensure that the installed device does not pose a danger, for example, hit someone by falling over. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 35: Additional Installation Information

    • Secure the device using additional measures. The mounting screws of the telescopic rails may not protrude more than 5 mm into the device. • Use the brackets on the front panel to carry and lift the unit. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 36: Mounting Holes

    230 V supply voltage of the USA and Canada • Type SJT with three conductors • The connector must be compliant with NEMA 5-15. • Conductor cross-section ≤ 18 AWG • Cable length ≤ 3 m SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 37: Connecting The Function Earth

    You can find information on the position of the functional earthing connection under "Rear of the device (Page 12)". Requirements • PH2 screwdriver • Cable lug for M4 • Function earth with minimum cross-section of 2.5 mm copper cable SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 38: Connecting The Power Supply

    1. Turn the on-off switch off (position "0"). Information on the position of the on-off switch is available in "Operator controls (Page 17)". 2. Insert the power cable in the corresponding electrical socket. Information on the position of the socket is available in "Power supply connections (Page 16)". SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 39: Connecting I/O Devices

    • Audio device with line in • Headphones • Microphone • Headset (with headphones and microphone) with the following standards: – OMTP: Standard for audio devices from Nokia, etc. – CTIA: Standard for audio devices from Apple® SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 40: Connecting Device To Networks

    You can operate on up to three monitors with the VGA, DP and HDMI cables. The output on the extended monitor can be the same as the main monitor or the extension desktop of the main monitor. You can configure it in windows screen and display setting. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 41: Commissioning The Device

    "Operator controls (Page 17)". The green POWER LED lights up. The module carries out a self-test. 2. Follow the instructions on the screen. Press <ESC> to enter setup. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 42: Switching Off The Device

    • Shut down the operating system and unplug the power plug from the rear of the device, see "Power supply connections (Page 16)". The device is switched off and fully disconnected from the mains voltage. No trickle current is flowing. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 43: Hardware Reset

    • Press the on/off button for more than 4 seconds. – The unit switches off. – Press the power button again to turn the device back on. Information on the position of the buttons is available under "Operator controls (Page 17)". SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 44: Operating The Device

    CHA Fan 2 Mode: – [Silent Mode]: Chassis Fan speed change keep stable and low noise. – [Auto Mode]: Chassis Fan speed change based on CPU temperature. – [Max]: Uses the Maximum speed. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 45: Trusted Platform Module (Tpm)

    In a system with 2 independently operated drives, the second drive has not yet been set up in the delivery state of the device. The drive setup can be performed with the pre-installed operating system. You have the option of backing up your data to this drive. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 46: Onboard Raid System

    The subsequent setup of an onboard RAID system is performed in the firmware under "Create RAID Volume". Once the onboard RAID system has been set up, it can be configured with the "Intel®Optane™ Memory and Storage Management" software. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 47 9. On the next screen, assign a name for the RAID system. 10.Select "RAID Level" and select the entry "RAID1(Mirror)" in the following selection window. A list of available drives is displayed. 11.Select "Select Disks". A list of available drives is displayed. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 48: Monitoring The Onboard Raid System With "Intel® Optane™ Memory And Storage

    You can find information on monitoring a RAID system with "Intel® Optane™ Memory and Storage Management" in the documentation or help for the software. Open "Intel® Optane™ Memory and Storage Management" 1. Select Start > Intel® Optane™ Memory and Storage Management. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 49: Integrating A New Drive Into An Onboard Raid System

    1. Select "Start" > "Intel® Optane™ Memory and Storage Management". 2. Select the "Manage" menu. 3. Select "Settings". 4. Set the "Auto-rebuild on hot plug" option to "Enabled". Configure the mounted drive under "Create Raid Volume". SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 50 Configure the mounted drive under "Create Raid Volume". Mount new drive during operation in the onboard RAID system (after an error has occurred) Requirement The system is configured to mount new drives manually (not automatically), see above. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 51 3. Select a new drive. 4. From the drive information, select the function "Mark as spare" ③. The drive is mounted to the onboard RAID system and appears in the mounted drives area. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 52: Data Synchronization In The Raid System

    The synchronization process may take quite some time, e.g. several hours, with extremely high drive load even days. In addition, system performance may be limited in the case of a manually started maintenance operation until completion of the maintenance phase. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 53: Expanding And Assigning Parameters To The Device

    • The front door is open; see "Opening the front door (Page 44)". • The device is fully disconnected from the line voltage, see "Switching off the device (Page 42)". • All connection cables are unplugged. • PH2 screwdriver SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 54 6.1 Open the device Procedure Standard enclosure Eco enclosure Remove the marked four retaining screws. ①. Move the cover in the direction as the arrow. Lift the cover from the back and remove it. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 55: Expansion Cards

    • The device is open, see important information in "Open the device (Page 53)". Procedure Standard enclosure Eco enclosure Remove the marked three screws and the card holder. Push the card holder out of the marked slots. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 56 Insert the expansion card into the slot. Secure the expansion card with the designated screw. Loosen the bracket by unscrewing its screw and place it on the expansion card. Secure the bracket. Close the device. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 57: Memory Modules

    • DDR2 and DDR3 memory modules are not compatible. Please make sure to install DDR4 Memory Module on this motherboard. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 58 3. Insert and press the memory module into the socket until the retaining clips snap back to the original place, and the memory module is seated properly. Recommended memory configurations The motherboard comes with Dual Inline Memory Modules (DIMM) slots designed for DDR4 (Double Data Rate 4) memory modules. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 59: Drives (Hdd/Ssd)

    • The device is fully disconnected from the line voltage, see Switching off the device (Page 42). • PH2 screwdriver Procedure for removing the HDD/SSD Standard enclosure Eco enclosure Remove the top cover of the device. (Page 53) Disconnect the power supply and data cables. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 60: Removing And Installing Internal Hdd/Ssd

    • The drive cage is taken out of the chassis. Removing internal HDD/SSD from a Standard enclosure Loosen the marked four screws on the drive cage plate and remove the HDD/SSD from the drive cage. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 61 • For a 2.5" HDD/SSD: Loosen the four marked screws securing the HDD/SSD from the inside of the drive cage. Installing the internal HDD/SSD To install the HDD/SSD, follow the above removal steps in reverse order. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 62: Device Maintenance And Repair

    PC components that are subject to wear. The table below indicates the intervals for this replacement. Component Replacement interval Drives 3 years Backup battery 5 years 5 years Filter pad Depending on the degree of soiling SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 63: Removing And Installing Hardware

    2. Pull the handle in the direction of the arrow ② to open the left-front door. 3. Unscrew the marked screws. 4. Pull the marked screw to open the fan bracket. 5. Remove the filter in the direction of the arrow. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 64 3. Lift the cover from the back and remove it. 4. Pull out the fan plug and remove the two screws securing the fan bracket. 5. Remove the filter in the direction of the arrow. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 65: Replacing The Device Fan

    6. Remove the fan in the direction of the arrow. 7. Pull the fan plug from the connector. Note The wind should blow into the chassis after the fan is installed. Make sure that you install the fan in the right direction. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 66 Procedure - Installing the fan To install the fan, follow the steps for removing it in reverse order. During installation, make sure that the arrow on the fan points away from the fan bracket. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 67: Changing The Backup Battery

    – Rated voltage: 3 VDC – Max abnormal charging current: 10 mA • For any requirements on product maintenance, contact Siemens Technical support (Page 103). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
  • Page 68 – Courant de charge anormal max. : 10 mA • Pour toute demande concernant la maintenance du produit, contactez le support technique (Page 103) Siemens. • Ne jetez pas au feu des piles au lithium, n'effectuez pas de soudage sur la pile, ne la rechargez pas, ne l'ouvrez pas, ne la court-circuitez pas, n'intervertissez pas les pôles, ne...
  • Page 69: Changing The Power Supply

    (Page 42)". • The device is open, see important information in "Open the device (Page 53)". • An original spare part, for example, a power supply with the same type. • PH2 screwdriver SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 70 7. Connect the cables to the drives and the motherboard. 8. Use cable ties to reattach the power supply cables to the enclosure. 9. Close the device. 10.Check the safe state of the device. 11.Switch on the power supply. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 71: Replacing The Processor

    • Operate the processor only at a clock frequency that is equal to or less than the permitted clock frequency. Procedure 1. Unlatch the fan rack on the heat sink and remove it. 2. Remove the highlighted fan connector. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 72 Processor type and clock frequency If you use a processor of a different type, perform the BIOS update firstly. During the BIOS update, the microcode matching the processor is loaded. Contact the SIEMENS support to update the BIOS if you changed a different processor.
  • Page 73: Replacing The Motherboard

    1. Remove the unnecessary modules from the slots, for example, the expansion card. 2. Note the assignment of all cables to the motherboard. 3. Disconnect all cables from the motherboard. 4. Remove the nine screws indicated in the following figure. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 74: Installing Operating System, Software And Drivers

    Installing operating system, software and drivers You can restore the factory settings of the target system (i.e. the volume partitions, the operating system with installed device drivers, and the SIEMENS software products). This allows you to restore your device quickly if it has suffered damage.
  • Page 75 5. Click Install to allow the computer to start the installation. The installation starts. 6. Click Finish. Step 2: install the Intel(R) Ethernet Network Adapters I226 1. Click Step 2: Intel(R) Ethernet Network Adapters I226. 2. Click to install the LAN driver. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 76 1. Click Step 5: Intel(R) SerialIO Software. 2. Click to install the software driver. 3. Click Yes to confirm the user account control question. 4. Click Accept to confirm the Readme File Information and move on. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 77 1. Click Step 9: Intel(R) Rapid Storage Technology Driver software. 2. Click to install the software driver. 3. Click Run to confirm the user account control question. 4. Press any key to continue in the cmd window. 5. Click Next to continue. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 78: Recycling And Disposal

    Due to their low level of pollutants, the devices described in these operating instructions can be recycled. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. Beep code Beeps Description 1 short beep Memory training success Beep loop Memory error SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 79: Technical Specifications

    350 W: (+3.3 V & +5 V≤105 W) – 500 W: (+3.3 V & +5 V≤105 W) – 500 W: (+3.3 V & +5 V≤105 W) – 850 W: (+3.3 V & +5 V≤200 W) SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 80 Device is designed for connection to supply with overvoltage category II (transient overvoltage up to 2500 V) Safety regulations • IEC/EN/UL 62368-1 • CAN/CSA-C22.2 No. 62368-1 Only with protected installation, see "Notes on ambient and environmental conditions (Page 25)" SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 81: Current/Power Requirements And Power Supply

    To achieve high power capacity for expansion slots, CPU turbo function should be disabled while consider- ing CPU turbo power consumption, or Pentium/Celeron CPU should be used. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 82: Technical Specifications Of Basic Power Supply

    The continuous maximum total output power must be ≤ 850 W. • For +12 V DC: Maximum output power 70 A (840W) • For +3.3 V and +5 V DC: Maximum combined output power must be ≤ 200 W. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 83: Electromagnetic Compatibility

    150 kHz to 80 MHz: 10 V, 80% AM (1 kHz) Magnetic field 30 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8) : Siemens recommends that you use the magnetic ring when you are using the 3m USB cable. SIMATIC IPC RW-543B...
  • Page 84: Ambient Conditions

    :The Max permitted power for expansion card can be up to 175W. (Expansion card, for example highend graphic card, which emits its waste heat directly out of the chassis) SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 85: Technical Specifications Of The Drives

    12 V / 5.5 A • 3.3 V / 0.4 A Max.permitted power consumption 5V, 5A or 3.3 V, 7A; 12V 0.5A; 3.3 Vaux 0.4A per PCI slot (5V,32-bit) : Compatible with Intel® LGA1700 socket 13th CPUs. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 86: Technical Specifications Of Graphic

    Full extraction length ≥ 470 mm Rail thickness ≤ 9.7 mm Mounting screws M5 x 6 mm The mounting screws of the telescopic rails may not protrude by more than 5 mm into the enclosure. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 87: Technical Specifications Of The Operating Systems

    This product meets the requirements of EC Directive 2014/30/EU "Electromagnetic Compatibility". The device is designed for the following areas of application corresponding to the CE marking: Scope of application Requirements for Interference emission Immunity to interference Industrial area EN 61000-6-4 EN 61000-6-2 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 88: Esd Guideline

    The material with which an electrostatically-charged person comes into contact is of particular significance. The figure shows the maximum electrostatic voltages with which a person is charged, depending on humidity and material. These values conform to the specifications of IEC 61000-4-2. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 89 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically by touching grounded metallic parts before you take a measurement at a module. Always use grounded measuring instruments. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 90: Dimension Drawings

    Dimension drawings Dimension drawing of Standard enclosure Front view and top view All dimensions in mm. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 91: Dimension Drawing Of Eco Enclosure

    Dimension drawings 9.2 Dimension drawing of Eco enclosure Dimension drawing of Eco enclosure Front view and top view All dimensions in mm. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 92: Dimension Drawing Of The Expansion Cards

    Dimension drawing of the expansion cards Long PCI card, PCIe card Dimension drawing of the telescope rails Dimension drawing for bore holes for telescopic rails (Standard enclosure) Dimensions: mm T1=Tolerances of ± (0.1mm)/(0.004") T2=Tolerances of ± (0.3mm)/(0.01") SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 93 Dimension drawings 9.4 Dimension drawing of the telescope rails Dimension drawing for bore holes for telescope rails (Eco enclosure) Dimensions: mm T1=Tolerances of ± (0.1mm)/(0.004") T2=Tolerances of ± (0.3mm)/(0.01") SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 94: Standards And Approvals

    RoHS EN IEC 63000:2018 ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets the requirements of ISO 9001:2015, ISO 14001:2015 and ISO 45001:2018. Certificate registration no. 01 100 1430201, 01 104 1430201 and 01 113 1430201.
  • Page 95 This product meets the requirements of the standard IEC/EN 61000-6-4 and AS/NZS 61000.6.4; Generic standards - Emission standard for industrial environments. This product meets the requirements of the standard IEC/EN 61000-6-4 and AS/NZS 61000.6.4; Generic standards - Emission standard for industrial environments. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 96 This product meets the requirements of India certification. BSMI This product meets the requirements of CNS15936, CNS 15598-1 generic standard. Table 10- 1 限用物質含有情況標示聲明 設備名稱:工業用電腦 Industrial PC, 型號(型式):SIMATIC IPC RW-543B Equipment name Type designation (Type) 單元 Unit 限用物質及其化學符號 Restricted substances and its chemical symbols 鉛 Lead 汞...
  • Page 97 Manchester M20 2UR United Kingdom The UK Declaration of Conformity is also available for download from the Siemens Industry Online Support website under the keyword "Declaration of Conformity". WEEE label (European Union) Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 78) ".
  • Page 98: Hardware Description

    Technical features of the motherboard Technical features of the motherboard can be found under "Technical specifications of the motherboard (Page 85)". For the detailed motherboard information, refer to User Manual (UM) for the motherboard (https://support.industry.siemens.com/cs/ww/en/view/109978327). SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 99: Position Of The Interfaces On The Motherboard

    ⑦ USB2.0 Vertical TYPE-A Connector ⑰ PCI Express x16 slots ⑧ SPI TPM header (14-1 pin TPM) ⑱ PCI slots ⑨ SATA 6.0Gb/s ports (7-pin SATA6G_4-6) ⑲ PCI Express x4 slots ⑩ PSU fan header (4-pin PSU_FAN) SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 100: External Interfaces

    USB 2.0 X68-1,X68-2 USB2.0 connector Ethernet X1P1, X2P1 RJ45 HDMI HDMI Type A connector Audio 3.5 mm audio jack • Line-Out X90 • Mic-In X91 Connection of an analog monitor 20-pin DisplayPort connector SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 101: Serial Interface

    Receive data - (I) for full-duplex mode Signal ground Pin assignment RS485 Short description Meaning Data- Transmit / receive data - (I/O) for half-duplex mode Data+ Transmit / receive data+ (I/O) for half-duplex mode Signal ground SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 102 Hardware description 11.2 External interfaces Short description Meaning SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 103: Technical Support

    Please check regularly if updates and hotfixes are available for download to your device. The download area is available on the Internet at the following link: After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 104: Troubleshooting

    2. Set the date and the time in the "Main" tab. Time and date are wrong even The backup battery is dead. Replace the backup battery. after correctly setting them in the firmware (BIOS) SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 105: Problems When Booting The Device

    You can find the files and descriptions needed for GPT data storage medium is this on the supplied data storage medium. aborted with the following error message: "Status: 0xc0000225 Info: The boot selection failed because a required device is inaccessible" SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 106: Problems When Using Expansion Cards

    Different pin assignment expansion card and restart the device. If the error no longer occurs, the expansion card was the cause of the fault. Replace this with a Siemens expansion card or contact the supplier of the ex- pansion card.
  • Page 107: Markings And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 108: Certificates, Approvals And Markings

    Commission for the USA EFUP (Environment Friendly Use Peri- Approved for Korea Certification (KC) od) marking for China Test mark of the Underwriters Labora- Disposal information, observe the tories local regulations. Approval for India BIS Certification SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 109: Interfaces

    LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 110: List Of Abbreviations

    Components sensitive to electrostatic charge European standard Hard Disk Drive Hard disk drive Height unit Input/Output Data input/output on computers iAMT Intel® Active Management Technology International Electrotechnical Commission Ingress Protection Degree of protection SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 111 Positive supply voltage of integrated circuits VEST Video Electronics Standards Association Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 112: Index

    Graphic controller, 86 Connections, (Interfaces) Country-specific information, 36 Hardware reset, 43 Headphones Data exchange, 40 Connecting, 39 Degree of protection, 80 Headset Device fan, 63 Connecting, 39 Maintenance interval, 62 Removing and installing, 63 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 113 35 Device fan, 63 with telescopic rails, 35 Mounting holes, 36 Safety instructions Ambient and environmental conditions, 25 New Zealand, 95 Device and system extensions, 28 General, 21 I/O devices, 27 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...
  • Page 114 Shutting down the operating system, 42 Switching on Switching on the device, 41 Telescopic rails Mounting holes, 36 Technical specifications (basic configuration), 86 Transportation, 24 UKCAI, 97 Vent slots, 34 vibration-damped drive cage, 14 SIMATIC IPC RW-543B Operating Instructions, 01/2025, A5E54139074-AA...