Summary of Contents for Siemens SIMATIC IPC PX-39A PRO
Page 1
SIMATIC IPC PX-39A PRO Preface Product description SIMATIC Safety instructions Mounting and connecting the device Industrial PC SIMATIC IPC PX-39A PRO Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair...
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions are valid for all order versions of the SIMATIC IPC PX-39A PRO. History The following editions of these operating instructions have already been published:...
In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens' products and solutions only form one element of such a concept. Siemens' products and solutions constitute one element of such a concept.
Notes on mounting ......................40 3.2.2 Prepared for support arm or pedestal without extension elements (flange on top) ....42 3.2.3 Prepared for support arm and extension elements (flange mount) ........45 SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 6
Maintenance intervals......................78 Cleaning the Device Front ....................79 Removing and installing hardware ..................80 7.4.1 Replacing the backup battery ..................... 80 7.4.2 Replace the M.2 NVMe SSD in the device ................81 SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 7
UL approval ........................108 10.6 FCC (USA) ........................109 10.7 Canada ..........................109 10.8 Australia / New Zealand ....................109 10.9 Eurasion Customs Union EAC ................... 110 10.10 Korea..........................110 10.11 Taiwan ..........................110 SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 8
Markings and symbols ........................122 Overview ......................... 122 Safety ..........................122 Operator controls ......................122 Certificates, approvals and markings ................123 Interfaces ........................124 List of abbreviations .......................... 125 Abbreviations ........................125 Index ..............................127 SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Boot modes Windows® operating Information on: • Online at: system • Commissioning the operating Microsoft® Windows® 10 system (https://support.industry.siemens. • Restoring the operating system com/cs/ww/en/view/109749498) • Configuration of the operating system SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 10
• Online at: bootable USB flash SIMATIC IPC Creating a bootable • Creating a bootable USB flash drive USB flash drive drive for recovery of operating (https://support.industry.siemens. system, software and drivers com/cs/ww/en/view/109811224) SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Product description 1.2 Product highlights Product highlights The SIMATIC IPC PX-39A PRO is a high-performance Industrial Panel PC. It is perfectly suited for PC applications with high-level industry functionality. Device view Note Depending on the configuration ordered the features and illustrations described in this manual may differ from the features of your device.
Page 12
– 24" display, resolution: 1920 x 1080 pixels • optionally prepared for: – Pedestal/extension elements (flange at bottom) – Support arm without extension elements (flange at top) – Support arm and extension elements (round tube) SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Data acquisition and management External design of the device 1.4.1 Devices with capacitive multi-touch screens Front view and side view ① Display with multi-touch screen ② Enclosure ③ Backplane cover ④ Terminal compartment cover SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 14
Example of bottom view "Device version pedestal without extension elements" ① Mechanical interface for fastening of the base adapter ② Terminal compartment cover ③ Mechanical interface for fastening of the base adapter SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 15
Mechanical interface for fastening of the round tube adapter ④ Cover plate Note The device version "prepared for support arm and extension components" is intended for devices with an extension (see System components (Page 18)). SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• SSD drive SSD2 X51, installed in the SIMATIC IPC Slider (shown as an example in the figure) • COM1 X30 • X100 expansion interface in M.2 format, led to the outside SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
① Seal ② Cable channel ③ Mechanical interface to the PRO device ④ Cover ⑤ Mechanical interface to support arm or stand Article number for the base adapter as accessory: 6AV7674-1KA00-0AA0. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
① Round tube adapter ② Ring groove for fastening on PRO device with setscrews ③ Mechanical interface to support arm Article number of the round tube adapter: 6AV7674-1KF00-0AA0 SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 20
(flange mount) (Page 45)". You can find Information on available accessories on the Internet at: • Industry Mall (https://mall.industry.siemens.com) • System components for devices with all-round IP65 protection (https://mall.industry.siemens.com/mall/de/de/Catalog/Products/10268745?tree=Catalog Tree) SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Adapter set for support arm and stand mounting of PRO device The PRO device can be mounted on systems from third-party vendors (see "Mounting the device (Page 40)"). For this, you will need the Siemens Base adapter (Page 18) and a proprietary adapter set.
• 19" • 22" • 24" For greater flexibility, three different connection options can be selected per size for the PLC connection of the operator controls: • Hardwired • PROFINET • PROFIsafe SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 23
In addition, different operator controls such as emergency stop, selector switch, illuminated pushbutton, keyswitch, indicator light or RFID reader are available. Note Only operator controls with Siemens approval may be installed in the Extension Unit. You can find information on "System Components for PRO Device Extension Units" at Internet (mall.industry.siemens.com/mall/de/de/Catalog/Products/10268745?tree=CatalogTree).
Accessories and replacement parts 1.7.1 Hardware accessories Accessories from Siemens are available for your device that are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall 1. On the Internet, go to Industry Mall (https://mall.industry.siemens.com).
• Disconnect the device from the power supply in good time when a thunderstorm is approaching. • Do not touch power cables and data transmission cables during a thunderstorm. • Keep sufficient distance from electric cables, distributors, systems, etc. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 26
It is therefore inevitable that the display will contain a small number of defective pixels. This does not limit the function in any way provided the defective pixels are not all in one location. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 27
The device contains electronic components which may be destroyed by electrostatic charge. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Do not operate the device in severe operating conditions which are subject to caustic vapors or gases. • For installation in a cabinet, observe the SIMATIC setup guidelines as well as the relevant DIN/VDE requirements or the applicable country-specific regulations. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Remove radiation sources from the environment of the device. • Switch off radiating devices. • Reduce the radio output of radiating devices. • Read the information on electromagnetic compatibility. • Read the information in the technical specifications. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• The IPC in question must be turned off and the power supply connector must be plugged • During the measurement, all cables from the plant to the IPC should be connected. • All other components in the plant must be active. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Always connect the device to a protective conductor. • Additional information on connecting the protective conductor can be found in the section "Connecting the protective conductor (Page 53)." SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 33
Do not touch the screen in the following situations: • During the boot process • When plugging or unplugging USB components • While Scandisk is running • During a BIOS update SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
You can find the latest information on additional software for your device under: "Software accessories (Page 24)". Printed documents • Quick Install Guide SIMATIC IPC PX-39A PRO • Product Information "Important notes on your device" SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
If the contents of the package are incomplete, damaged or do not correspond to your order, you can use the After Sales Information System (ASIS) (http://siemens.com/asis) to provide feedback on product deliveries and repairs. Complete the online form for product delivery (quality control notification) under the heading "Product delivery: Feedback on quality control and repairs".
The following illustrations are examples. The data of your device may differ from the data in these examples. Nameplate The following figure shows the nameplate on the SIMATIC IPC PX-39A PRO as an example. COA label The COA label (Certificate of Authenticity) is located under the terminal compartment cover of the device, see "Opening and closing the terminal compartment cover (Page 50)"...
Device version prepared for pedestal/extension components (flange at bottom) Operating Deviation from the vertical position ① Inclined ≤ 45° ② Vertical 0° SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 39
Device version prepared for support arm without extension components (flange at top) Operating position ① Inclined ≤ 45° ② Vertical 0° Device version "prepared for support arm and extension components (round tube)" Operating position ① Inclined ≤ 45° ② Vertical 0° SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
If there are no seals on the mechanical interfaces or if they are damaged, IP65 degree of protection and Enclosure Type 4X / 12 (indoor use only) is at risk. • Check the condition and proper seating of the seals. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 41
Liability disclaimer The device is mounted to a pedestal or a support arm via the mechanical interface with screws. Siemens AG assumes no liability for the consequences of incorrect installation. Warranty at risk If you do not install the HMI device in accordance with the specifications in these operating instructions, the warranty for the device is voided.
Requirements • All packaging components and protective films have been removed. • Siemens base adapter with screws (supplied with the device version "Prepared for pedestal / extension elements (flange at bottom)" and "Prepared for support arm / extension elements (flange at top).
Page 43
Installation on a pedestal is carried out in the same way. 1. If an adapter plate for the Siemens base adapter is included in your support arm system, attach the adapter plate to the support arm with 4 M6x12 screws.
Page 44
7. Connect all cables according to the description in the section "Connecting the device". 8. Fasten the cover plate ⑤ to the device with the 2 screws, torque 1.5 Nm. Check that the seal is sitting correctly. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
– Support arm with mechanical interface, appropriate for the flange of the round tube adapter, and Siemens round tube adapter (not included in product package) – Support arm with mechanical VESA interface, the corresponding Siemens adapter set and the Siemens round tube adapter (not included in product package) See "System components (Page 18)"...
Page 46
The following description shows an example of how to attach the PRO device to a support arm system using the optionally available Siemens round tube adapter ⑦. Mounting to a 48.3 mm round tube ⑧ that fits the opening of the PRO device is performed in a similar fashion.
Page 47
Otherwise the device can become loose due to vibrations and drop. 4. If an adapter plate for the Siemens round tube adapter is included with your support arm, attach the adapter plate to the support arm with 4 M6x12 screws.
Page 48
9. Fasten the cover plate ⑨ from the PRO device product package with 4 M4x12 screws, torque 1.5 Nm. Alternatively, you can extend the PRO device by adding an Extension Unit at the bottom. Read the associated documentation. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
The 24 V DC power supply is protected against polarity reversal. If you mix up the 24 V DC connecting cables and ground, the device is not damaged but does not switch on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Opening the terminal compartment cover ① for pedestal and support arm device versions without extension elements. Opening the terminal compartment ① for device version prepared for support arm and extension elements (round tube). SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 51
The assignment of the interfaces is shown on the inside of the terminal compartment cover. 3. Run the connecting cables through the support arm or pedestal ① into the PRO device and connect them to the interfaces on the inside. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 52
3. Tighten the M4x16 screws of the terminal compartment cover using a maximum torque of 1.5 Nm. Note Do not exceed the permissible torque If you tighten up the M4x16 screws with a torque of > 1.5 Nm, you may damage the threading in the enclosure. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Tighten the M4 screw with a torque of max. 1.5 Nm. 3. Connect the protective conductor to the protective conductor connection of the control cabinet from which the PRO device is supplied. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Plug the connecting terminal into the connection socket at the indi- cated position. The connecting terminal must snap into the connection socket. Secure the power supply cable to the strain relief with a cable tie. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
The following table shows the various connection options for the monitors on the device interfaces. Motherboard DPP1 DPP2 Monitor 1 Monitor 2 1) - via DP to DVI-D adapter 2) - via DP-VGA adapter SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Control level. You can find information on this under "SIMATIC NET (http://w3.siemens.com/mcms/automation/en/industrial- communications/Pages/Default.aspx)". The software package and the documentation are not included in the scope of delivery. More information You can find more information at "Technical Support (https://support.industry.siemens.com)". SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Cutting tool (not included in the scope of delivery) Procedure 1. Pass the cable tie around the strain relief bar ① and secure the cables as shown. ① Fastening bars 2. Cut off the protruding ends of the cable ties. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
You can find information on first startup of the device and commissioning the installed Windows® operating system in the operating system documentation. See also "Important instructions and manuals for operating the device (Page 9)" for more on this. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• The device may be damaged. Perform a hardware reset only in the case of an emergency. • Operate the on/off switch to initiate a hardware reset, see "Interfaces and operating elements (Page 16)". SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• In addition, you operate via gestures that are supported by the operating system or software installed on the device. Note Multi-touch operation can provide advanced features or pose limitations depending on the operating system and the software installed on the device. Observe the corresponding documentation. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
– Ethernet Monitor settings For information on the software and documentation of "SIMATIC IPC Panel Drivers and Tools", refer to the detailed PDT description, see "Important instructions and manuals for operating the device (Page 9)". SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Reset off: No action is performed • A change to the monitoring time is effective immedi- • The device is restarted ately. • The device is shut down SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
IPC DiagBase monitoring software is installed. Information on the software and documentation of SIMATIC IPC DiagBase can be found under: • SIMATIC IPC DiagBase (https://support.industry.siemens.com/cs/ww/de/view/109749690) • Important instructions and manuals for operating the device (Page 9) 5.3.3 SIMATIC IPC DiagMonitor The SIMATIC IPC DiagMonitor monitoring software can be ordered optionally.
You configure iAMT with Intel® Management Engine BIOS Extension (MEBx) in the firmware/BIOS. You can find information on this in the detailed firmware/BIOS description, see "Important instructions and manuals for operating the device (Page 9)". SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
512 KB can be displayed by means of a PCI address register. The base address is initialized by the BIOS. A corresponding function is implemented there for using the SIMATIC Software Controller. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. Requirements • The device is disconnected from the power supply. • All connecting cables are unplugged. • Screwdriver type Torx T20 SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 67
1. Loosen the two indicated M4x16 screws of the terminal compartment cover ② (the screws are captive in the covers). 2. Open the terminal compartment cover ② and put it down safely (see also "Opening and closing the terminal compartment cover (Page 50)"). SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 68
2. Disconnect the plugs of the power supply cables (see "Connecting the power supply (Page 50)"). 3. Disconnect the power supply plug ⑤ on the motherboard. 6. Now you can install and remove the hardware. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 69
5. Tighten the M4x16 screws of the backplane cover in crosswise order using a maximum torque of 1.5 Nm. Check all screws again to ensure that the maximum torque of 1.5 Nm has not been exceeded. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• The connection cable between the M.2 module and the interface card should be at least 150 mm long. See also Position of the interfaces on the motherboard (Page 112) Dimension drawing of expansion modules (M.2) (Page 106) SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Note: Make sure that the M.2 module is between the head and the spacer of the screw. If the M.2 module includes a cable with an additional interface card ③ that must be connect- ed to the enclosure opening, you must also execute the following steps: SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 72
Connect the cable of the interface card to the M.2 module. Close the device as specified in section "Opening and closing the backplane cover (Page 66)". Procedure - Removal Proceed in reverse order of installation. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Memory transaction rate 3200 MT/sec "unbuffered" • "without ECC" or "with ECC" Note Use only the memory modules recommended by Siemens AG. Requirement • The device is disconnected from the power supply. • The device is open, see important information under "Opening and closing the backplane cover (Page 66)".
Page 74
3. Close the device. After insertion and removal Close the device. The new memory capacity will be automatically detected and displayed in the BIOS setup when the device is switched on. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Drives 6.4.1 Usable SSDs The two M.2 NVMe SSDs that can be used for SIMATIC IPC PX-39A PRO can be installed in the following locations (one each): • Replacing the M.2 NVMe SSD in the SIMATIC IPC Slider (Page 75) •...
Page 76
Remove the black plastic cover. Remove the marked screw with the type Torx T8 screwdriver. Remove the M.2 NVMe SSD from the Slider as shown. Carefully separate the M.2 NVMe SSD from the adapter plate. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 77
"Opening and closing the terminal com- partment cover (Page 50)". Note To ensure reliable operation of the devices with SIMATIC IPC Slider, the Slider must be closed with the cover. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
As soon as the Smart status of the data storage medium goes to "Not OK", a message is generated in SIMATIC IPC DiagBase or SIMATIC IPC DiagMonitor or also during a system start of the device. You should then back up your data and replace the drive. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• See the notes under "Notes on ambient and environmental conditions (Page 29)". Cleaning the Device Front 1. Switch off the device. 2. Dampen the cleaning cloth. 3. Clean the device with the cleaning cloth. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
2. Place the new battery below the two con- tacts (1) and press it into the base (2) while applying slight pressure. 3. Close the device. 4. Check the firmware/BIOS settings. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
2. Hold the SSD drive carrier and remove the marked screws of the SSD drive carrier with the type Torx T10 screwdriver. 3. Remove the SSD drive carrier and put it down safely. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 82
Proceed in reverse order for the installation. 1. In step 1. above, ensure that the plug-in card is not installed twisted. 2. Close the device. See also Installing/removing expansion module (M.2) (Page 71) SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Installing operating system, software and drivers You can restore the factory settings of the target system (i.e. the volume partitions, the operating system with installed device drivers, and the SIEMENS software products). This allows you to restore your device quickly if it has suffered damage.
Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device, and dispose of it according to the relevant regulations in your country. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
< 40 dB(A) according to DIN 45635-1 Degree of protection • IP 65 to IEC60529 • Enclosure nach UL50 Type 4X / 12 (indoor use only) Quality assurance In accordance with ISO 9001 SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 86
If the device is installed in an enclosure that complies with section 9.3.2. c) of IEC/UL/EN/DIN-EN 61010-1 und IEC/UL/EN/DIN-EN 61010-2-201, it can be supplied from a "Higher Limited Energy" source. The device is then classified as "OPEN EQUIPMENT". not evaluated by UL SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Scenario" = "Max Performance" USB ports - additional 0.5 A 12 W NVMe SSDs in the SIMATIC IPC Slider - addi- 0.25 A 5.9 W tional M.2 slots - additional 0.25 A 5.9 W SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
80% AM to IEC 61000-4-3 • 10 V 10 KHz – 80 MHz, 80% AM to IEC 61000-4-6 Immunity to magnetic fields 100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8) SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
The CPU performance settings can be made in the BIOS Setup, menu "Advanced" > "Pow- er&Performance" > "CPU Power Management Control" > "Power&Performance Scenario". Standard operating position: Vertical installation in horizontal format Inclined installation in horizontal format with a vertical inclination of maximum ±45 ° SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Buffer memory 512 KB NVRAM Expansion slot Refer to "Current and power requirements of the system compo- nents (Page 87)" for information on the maximum allowable per- formance values of the expansion slot. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example, time- controlled via screen saver or centrally via PROFIenergy. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
No teaming with iAMT When using iAMT, the X1 P1 interface must be used to connect to remote maintenance. Only possible with ports X1 P1 and X2 P1 SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
The following table lists the partitioning for disks ≥ 200 GB in GPT mode: Partition Name Size File system First Boot 260 MB FAT32 Second 128 MB None Third System 160 GB NTFS Fourth WinRE 500 MB NTFS Fifth Data Remainder NTFS SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Dimension drawings Dimension drawing of 15" device with capacitive multi-touch screen Prepared for pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 95
Dimension drawings 9.1 Dimension drawing of 15" device with capacitive multi-touch screen Prepared for support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 96
Dimension drawings 9.1 Dimension drawing of 15" device with capacitive multi-touch screen Prepared for support arm and extension elements ① Without round tube adapter ② With round tube adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
9.2 Dimension drawing of 19" device with capacitive multi-touch screen Dimension drawing of 19" device with capacitive multi-touch screen Prepared for pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 98
Dimension drawings 9.2 Dimension drawing of 19" device with capacitive multi-touch screen Prepared for support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 99
Dimension drawings 9.2 Dimension drawing of 19" device with capacitive multi-touch screen Prepared for support arm and extension elements ① Without round tube adapter ② With round tube adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
9.3 Dimension drawing of 22" device with capacitive multi-touch screen Dimension drawing of 22" device with capacitive multi-touch screen Prepared for pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 101
Dimension drawings 9.3 Dimension drawing of 22" device with capacitive multi-touch screen Prepared for support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 102
Dimension drawings 9.3 Dimension drawing of 22" device with capacitive multi-touch screen Prepared for support arm and extension elements ① Without round tube adapter ② With round tube adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
9.4 Dimension drawing of 24" device with capacitive multi-touch screen Dimension drawing of 24" device with capacitive multi-touch screen Prepared for pedestal ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 104
Dimension drawings 9.4 Dimension drawing of 24" device with capacitive multi-touch screen Prepared for support arm ① Without base adapter ② With base adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 105
Dimension drawings 9.4 Dimension drawing of 24" device with capacitive multi-touch screen Prepared for support arm and extension elements ① Without round tube adapter ② With round tube adapter All dimensions in mm SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Maximum dimensions of the expansion modules M.2 Key B Dimension drawing of the interface card with indication of the maximum possible dimensions ① Maximum possible dimensions of the plug cutouts ② Area for cable outlet SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and electronic equipment" (RoHS Directive) EU Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: Panel PC certificates (http://support.automation.siemens.com/WW/view/en/10805572/134200). SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
DIN ISO 9001 certificate and software license agreements ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
This product meets the requirements of EN 61000-6-3 Generic standards – Emission standard for industrial environments. This product meets the requirements of the standard EN 61000-6-3 Generic standards - Emission standard for industrial environments. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. 10.11 Taiwan Taiwan This product meets the requirements of the CNS14336-1(099/09/30), generic standard CNS13438(095/06/01). SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Slot for M.2 NVMe SSD in the device ③ Slot for expansion module (M.2) ④ Backup battery Technical features of the motherboard Technical features of the motherboard can be found under "Technical specifications of the motherboard (Page 90)". SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
WDT control register Base address + offset 6 WDT counter register Base address + offset 7 WDT status register The following tables describe the system resources for the factory state of the device. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Reserved Reserved CMOS battery capacity is still sufficient CMOS battery capacity is exhausted (remain- ing capacity is still sufficient for approx. 1 month) CMOS battery is empty or missing Reserved Reserved Reserved SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
This step resets the "PC ON/WD" LED from pulsing red to its normal state (lit green). The WDT starts counting down. To prevent this behavior, stop the WDT before resetting the status to "Active". SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
PCI register address: PCI register content: Length of the memory area NVRAM base address register NVRAM memory address (default) E300 0000 Address is assigned dynamically 80000 h (depending on device configura- tion) SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (https://www.siemens.com/supportrequest) • After-sales information system for SIMATIC PC / PG (https://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
1. Call the firmware/BIOS configuration menu. To do this, press the "<Esc>" button during the boot process and then select "Setup Utility". 2. Set the date and time in the "Main" tab and save the changes. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
• Signal frequencies or signal pansion card was the cause of the fault. Replace this with a levels are not adhered to Siemens expansion card or contact the supplier of the expan- • Different pin assignment sion card. If the device still crashes, contact your technical support team.
Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- On/off switch, without electrical isola- tion tion SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
EFUP (Environment Friendly Use Peri- Approved for Korea od) marking for China Test mark of the Underwriters Labora- UKCA marking for Great Britain tories Approval for India Disposal information, observe the local regulations. Approval for Taiwan SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Digital display interface with digital and VGA signals Error checking and correction Error correction code Extensible Firmware Interface Electrostatic-sensitive components European standard Ground Chassis ground Hard Disk Drive Hard disk drive Height unit SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Page 126
US organization for tests and certifications accord- ing to own or binational standards (with CSA / Canada) standards. Universal Serial Bus Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC PX-39A PRO Operating Instructions, 08/2024, A5E51699950-AB...
Need help?
Do you have a question about the SIMATIC IPC PX-39A PRO and is the answer not in the manual?
Questions and answers