Page 1
This Owner's Manual is provided and hosted by Appliance Factory Parts. THERMALZONE 10115R Owner's Manual Shop genuine replacement parts for THERMALZONE 10115R Find Your THERMALZONE Air Conditioner Parts - Select From 27 Models -------- Manual continues below --------...
Page 2
WINDOW AIR CONDITIONER INSTALLATION OPERATION CATALOG NO. PRODUCT CODE CATALOG NO. PRODUCT CODE WAC10115R 420-0011 WAH8115M 420-0023 WAC12230R 420-0013 950-0077-revD Page 1 of 16 9 May 2007...
TABLE OF CONTENTS AIR CONDITIONER SAFETY………………………………………………….….2 INSTALLATION REQUIREMENTS………………………………………………3 ELECTRICAL REQUIREMENTS…………………………………………………4 INSTALLATION INSTRUCTIONS………………………………………………..6 AIR CONDITIONER USE…………………………………………………………10 AIR CONDITIONER CARE……………………………………………………….13 TROUBLESHOOTING………………………………………………………….…14 SPECIFICATIONS…………………………………………………………………15 WARRANTY………………………………………………………………………...16 TECHNICAL SUPPORT IF YOU NEED TECHNICAL SUPPORT, PLEASE CALL (705) 504-8590 BETWEEN THE HOURS OF 8:00 A.M. and 5:00 P.M. EST. PLEASE HAVE THE MODEL NUMBER AND SERIAL NUMBER OF YOUR EQUIPMENT AVAILABLE WHEN YOU CALL.
IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock, or injury when using your air conditioner, follow these basic precautions: • • Plug into a grounded 3 prong outlet. Do not use an extension cord • • Do not remove ground prong Unplug air conditioner before servicing •...
ELECTRICAL REQUIREMENTS Window Installation Window opening measurements: • 27” min to 38” max (68.6 cm to 95.5cm) opening width. • 16 ¼” min. (41.3 cm) opening height. Ground wire must be connected to ground screw located in lower Through-the wall installation right corner of air conditioner when air conditioner is in cabinet.
Page 6
It is the customer’s responsibility to: • Contact a qualified electrical installer. • Assure that the electrical installation is adequate and in accordance with National Electrical Code, NNSI/NFPA 70- latest edition, and all local codes and ordinances. Copies of the standards listed may be obtained from: National Fire Protection Association One Batterymarch Park Quincy, MA 02269...
INSTALLATION INSTRUCTIONS UNPACKING Pull off the control knobs (on some models) Remove the two screws from the front panel. Remove packaging materials • Remove and dispose or recycle all packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid Remove the front panel from the air conditioner dish soap over the adhesive with your fingers.
Page 8
Attach Side Curtains Attach Foam Adhesive Seal ______________________________________________ _______________________________________________________ Locate provided bag of screws Attach foam adhesive seal along the bottom of the curtain bottom channel. Insert top and bottom of right-hand curtain housing in top and bottom curtain guides on air-conditioner cabinet.
Page 9
Use a 3/16” drill bit to drill 3 starter holes 3/8” deep Insert one of the #10 x ¾” round-head screws through hole through the 3 holes in the cabinet and into the windowsill. and into lower window sash. Insert one of the #10 x ¾” round-head screws through threaded hole in top of curtain.
Page 10
Complete Installation Position ground wire pointing straight up. Put excess ground wire between coil and air conditioner cabinet NOTE: Handle the air conditioner gently. Make sure the free end of the ground wire is outside of the cabinet. Insert air conditioner into cabinet. REMEMBER: Make sure the free end of the ground wire is outside of the cabinet.
AIR CONDITIONER USE Operating your air-conditioner properly helps you obtain the best possible results. Do not try to operate your air conditioner in the cooling mode when outside temperature is below 65º F (18ºC). The inside evaporator coil This section explains proper air conditioner operation will freeze up, and the air conditioner will not operate properly.
Page 12
______________________________________________________ To set the timer to turn on the air conditioner, changing the TEMPERATURE previous settings: _______________________________________________________ 1. Turn on air conditioner. Press the plus button to raise the temperature. Display shows the temperature control setting. Each time you press or hold the plus 2.
Page 13
To turn the air conditioner on or off To set Timer for a 1- to 24-hour delay before air conditioner is turned off (air conditioner must be on): Press POWER 1. Press TIMER. Indicator light on air conditioner control panel will flash.
______________________________________________________ ______________________________________________________ FAN SPEED TEMPERATURE _______________________________________________________ _______________________________________________________ Set FAN SPEED to the desired setting. When the air conditioner is Cooling operating at Low Heat or High Heat, Low Cool, High Cool, the fan Turn the TEMPERATURE control to a setting on the right-hand side circulates air continuously.
TROUBLESHOOTING Before calling for service, try the suggestions below to see whether you can solve your problem without outside help. Electrical overloading, overheating, pinched cord can trip _______________________________________________________ (Reset button will pop out) the power supply cord. Air Conditioner will not operate _______________________________________________________ After correcting the problem, press and release RESET (Listen for click;...
_______________________________________________________ Water drips from cabinet into your house _______________________________________________________ The air conditioner in the heating mode has insufficient BTU/H for the heating requirements of the room The air conditioner is not properly leveled. The air conditioner should slope slightly downward toward the outside. Level the air Do not use the air conditioner as a primary source of heat.
WARRANTY International Refrigeration Products warrants that the product supplied is free from defects in material and workmanship. This warranty is valid as long as this product is properly handled, installed, operated and serviced in accordance with the Installation and Operating Instructions shipped with this unit, and the warranty card is completed and mailed no later than 30 days after date of purchase.
Need help?
Do you have a question about the 10115R and is the answer not in the manual?
Questions and answers