Thermal Zone WAC10115R Installation And Operation Manual

Window air conditioner
Hide thumbs Also See for WAC10115R:

Advertisement

Quick Links

CATALOG NO.
WAC10115R
WAC12230R
950-0077-revD
WINDOW
AIR CONDITIONER
INSTALLATION
OPERATION
PRODUCT CODE
420-0011
420-0013
AND
Page 1 of 16
CATALOG NO.
PRODUCT CODE
WAH8115M
420-0023
9 May 2007

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WAC10115R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Thermal Zone WAC10115R

  • Page 1 WINDOW AIR CONDITIONER INSTALLATION OPERATION CATALOG NO. PRODUCT CODE CATALOG NO. PRODUCT CODE WAC10115R 420-0011 WAH8115M 420-0023 WAC12230R 420-0013 950-0077-revD Page 1 of 16 9 May 2007...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS AIR CONDITIONER SAFETY………………………………………………….….2 INSTALLATION REQUIREMENTS………………………………………………3 ELECTRICAL REQUIREMENTS…………………………………………………4 INSTALLATION INSTRUCTIONS………………………………………………..6 AIR CONDITIONER USE…………………………………………………………10 AIR CONDITIONER CARE……………………………………………………….13 TROUBLESHOOTING………………………………………………………….…14 SPECIFICATIONS…………………………………………………………………15 WARRANTY………………………………………………………………………...16 TECHNICAL SUPPORT IF YOU NEED TECHNICAL SUPPORT, PLEASE CALL (705) 504-8590 BETWEEN THE HOURS OF 8:00 A.M. and 5:00 P.M. EST. PLEASE HAVE THE MODEL NUMBER AND SERIAL NUMBER OF YOUR EQUIPMENT AVAILABLE WHEN YOU CALL.
  • Page 3: Installation Requirements

    IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock, or injury when using your air conditioner, follow these basic precautions: • • Plug into a grounded 3 prong outlet. Do not use an extension cord • • Do not remove ground prong Unplug air conditioner before servicing •...
  • Page 4: Electrical Requirements

    ELECTRICAL REQUIREMENTS Window Installation Window opening measurements: • 27” min to 38” max (68.6 cm to 95.5cm) opening width. • 16 ¼” min. (41.3 cm) opening height. Ground wire must be connected to ground screw located in lower Through-the wall installation right corner of air conditioner when air conditioner is in cabinet.
  • Page 5 It is the customer’s responsibility to: • Contact a qualified electrical installer. • Assure that the electrical installation is adequate and in accordance with National Electrical Code, NNSI/NFPA 70- latest edition, and all local codes and ordinances. Copies of the standards listed may be obtained from: National Fire Protection Association One Batterymarch Park Quincy, MA 02269...
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS UNPACKING Pull off the control knobs (on some models) Remove the two screws from the front panel. Remove packaging materials • Remove and dispose or recycle all packaging materials. Remove tape and glue residue from surfaces before turning on the air conditioner. Rub a small amount of liquid Remove the front panel from the air conditioner dish soap over the adhesive with your fingers.
  • Page 7 Attach Side Curtains Attach Foam Adhesive Seal ______________________________________________ _______________________________________________________ Locate provided bag of screws Attach foam adhesive seal along the bottom of the curtain bottom Insert top and bottom of right-hand curtain housing in channel. top and bottom curtain guides on air-conditioner cabinet.
  • Page 8 Use a 3/16” drill bit to drill 3 starter holes 3/8” deep Insert one of the #10 x ¾” round-head screws through hole through the 3 holes in the cabinet and into the windowsill. and into lower window sash. Insert one of the #10 x ¾” round-head screws through Attach cabinet to windowsill with 3 - #10 x 1/2”...
  • Page 9 Complete Installation Position ground wire pointing straight up. Put excess ground wire between coil and air conditioner cabinet NOTE: Handle the air conditioner gently. Make sure the free end of the ground wire is outside of the cabinet. Insert air conditioner into cabinet. REMEMBER: Make sure the free end of the ground wire is outside of the cabinet.
  • Page 10: Air Conditioner Use

    AIR CONDITIONER USE Operating your air-conditioner properly helps you obtain the best possible results. Do not try to operate your air conditioner in the cooling mode when outside temperature is below 65º F (18ºC). The inside evaporator coil This section explains proper air conditioner operation will freeze up, and the air conditioner will not operate properly.
  • Page 11 ______________________________________________________ To set the timer to turn on the air conditioner, changing the TEMPERATURE previous settings: _______________________________________________________ 1. Turn on air conditioner. Press the plus button to raise the temperature. Display shows the temperature control setting. Each time you press or hold the plus 2.
  • Page 12 To turn the air conditioner on or off To set Timer for a 1- to 24-hour delay before air conditioner is Press POWER turned off (air conditioner must be on): 1. Press TIMER. Indicator light on air conditioner control panel will flash.
  • Page 13: Air Conditioner Care

    ______________________________________________________ ______________________________________________________ FAN SPEED TEMPERATURE _______________________________________________________ _______________________________________________________ Set FAN SPEED to the desired setting. When the air conditioner is Cooling operating at Low Heat or High Heat, Low Cool, High Cool, the fan Turn the TEMPERATURE control to a setting on the right-hand side circulates air continuously.
  • Page 14: Troubleshooting

    TROUBLESHOOTING Before calling for service, try the suggestions below to see whether you can solve your problem without outside help. Electrical overloading, overheating, pinched cord can trip _______________________________________________________ (Reset button will pop out) the power supply cord. Air Conditioner will not operate _______________________________________________________ After correcting the problem, press and release RESET (Listen for click;...
  • Page 15: Specifications

    See the Installation Instructions. NOTE: Do not drill a hole into the bottom of the metal base and condensate pan SPECIFICATIONS SPECIFICATIONS WAH8115M WAC10115R WAC12230R COOLING BTU 8000 10000 12000 HEATING BTU...
  • Page 16: Warranty

    WARRANTY International Refrigeration Products warrants that the product supplied is free from defects in material and workmanship. This warranty is valid as long as this product is properly handled, installed, operated and serviced in accordance with the Installation and Operating Instructions shipped with this unit, and the warranty card is completed and mailed no later than 30 days after date of purchase.

This manual is also suitable for:

Wac12230rWah8115m420-0011420-0013420-0023