Thermal Zone MAC12 Owner's Manual

Thermal Zone MAC12 Owner's Manual

Mobile air conditioner
Hide thumbs Also See for MAC12:

Advertisement

Quick Links

This Owner's Manual is provided and hosted by Appliance Factory Parts.
THERMALZONE MCH12/7
Owner's Manual
Shop genuine replacement parts for THERMALZONE
MCH12/7
Find Your THERMALZONE Air Conditioner Parts - Select From 27 Models
-------- Manual continues below --------

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAC12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermal Zone MAC12

  • Page 1 This Owner's Manual is provided and hosted by Appliance Factory Parts. THERMALZONE MCH12/7 Owner's Manual Shop genuine replacement parts for THERMALZONE MCH12/7 Find Your THERMALZONE Air Conditioner Parts - Select From 27 Models -------- Manual continues below --------...
  • Page 2 READ THIS MANUAL THOROUGHLY MOBILE AIR CONDITIONER Models: MAC12 12,000 Btu Cooling Only MCH12/7 12,000 Btu Cooling, 7,000 Btu Heating 950-0030-revB 1-15-07...
  • Page 3: Table Of Contents

    CONTENTS ………………………………………………………………………………………………… 3 Introduction ……………………………………………………………………………………… 3 Theory of Operation Technical Specifications ……………………………………………………………………………………… 4 Structure………………………………………………………………………………………………………… 5 Operation………………………………………………………………………………………………………… 6 Accessories Installation……………………………………………………………………………………… 20 Maintenance…………………………………………………………………………………………………… 23 Trouble Shooting……………………………………………………………………………………………… 24 Safety Caution and Special Guideline………………………………………………………………………25 Warranty Statement…………………………………………………………………………………………… 26...
  • Page 4: Introduction

    Introduction Mobile Air Conditioner This Mobile Air Conditioner is a small size appliance which can control the temperature and humidity in a room. Its flexible characteristics make it easy to use on different occasions and in different rooms. It also has multiple functions including cooling, heating, dehumidifying, and fan ventilation.
  • Page 5: Technical Specifications

    Technical Specifications Model MAC12 MCH12/7 EER Rating Btu/w Cooling Capacity 12,000BTU 12,000BTU Heating Capacity 7,000BTU Rated Voltage 115Vac 115Vac Rated Frequency 60Hz 60Hz Rated Current 14.6Amps 14.6Amps Power Input 1200W 1200W cooling/1500W heating Rated Input 1500W 1500W Cycling Airflow 174 CFM...
  • Page 6: Structure

    STRUCTURE Front Back...
  • Page 7: Operation

    OPERATION ATTENTION: DEHUMIDIFYING AND COOLING OPERATION The operating ranges for cooling and dehumidifying operation is 62ºF - 95ºF. LOCATION: Put the mobile air conditioner at an open place where the air outlets cannot be covered up. Place the unit no less than 20 inches away from a wall or other obstacle. POWER SUPPLY: Before connecting the air conditioner to the power supply, please check: The power supply is rated voltage 115V +- 6%.
  • Page 8 OPERATION In order to prevent power fluctuations during the start of the compressor, the following installation conditions apply: 1. The power source must be capable of handling 16A continuous. 2. Avoid connecting other equipment to this power source. 3. For power details of the air conditioner, refer to the rating plate of the product.
  • Page 9: Control Panel And Lcd

    OPERATION CONTROL PANEL AND LCD...
  • Page 10 OPERATION CONTROL PANEL – BUTTONS TURN THE AIR CONDITIONER ON: Press the power ON/OFF button. This will turn the unit on. MODE BUTTON “MODE”: There are 5 running modes to choose from: FAN ⇒ COOL ⇒ DRY ⇒ HEAT ⇒ AUTO NOTE: Only Model MCH12/7 has the heat function.
  • Page 11: Cooling Operation

    OPERATION COOLING OPERATION Ensure that the drain tank is properly placed in the unit. Install the exhaust duct properly (see air exhaust duct page). During the cooling operation, always place the duct through an open window, or outside of the area being cooled.
  • Page 12: Water Drainage

    OPERATION WATER DRAINAGE When operating the air conditioner in cooling or dehumidifying mode under normal conditions, the condensation water is automatically evaporated from an internal drip pan out through the exhaust duct. Under extremely high humidity conditions, the water in the drip pan may reach a level that triggers a shut-off mechanism.
  • Page 13: Remote Control Description

    OPERATION REMOTE CONTROL DESCRIPTION : NOTE Please point the remote control at the signal receiver on the unit panel. The information displayed can be transmitted at the mode AUTO, ON/OFF, SLEEP, SWING, and TRANSMIT. The other buttons can only change the messages which should be transmitted within 15 seconds;...
  • Page 14 OPERATION MAIN BUTTONS AND FUNCTIONS NOTE: If the power fails, disconnect and reconnect the power cable. Press the send button on the wireless remote control to restart the unit.
  • Page 15: Cooling Mode

    OPERATION COOLING MODE...
  • Page 16 OPERATION HEATING MODE (ONLY FOR MODEL MCH12/7) NOTE: In the heat mode, only the heating element and the blower will operate.
  • Page 17 OPERATOIN DEHUMIDIFYING (DRY MODE) NOTE: The compressor is running and the upper fan is running in low speed.
  • Page 18: Sleep Mode

    OPERATION SLEEP MODE NOTE: To set the timer in the sleep mode, press the Hr button to select TIMER (displayed on LCD), press the + or – to select hours. In the sleep mode, the fan will go to low speed and the temperature will automatically adjust during the selected hours providing a comfort temperature for sleeping.
  • Page 19: Auto Mode

    OPERATION AUTO MODE...
  • Page 20: Timer Setting

    OPERATION TIMER SETTING NOTE: When Timer is set, the air conditioner will turn off immediately. When the set time is reached, the unit will turn on again satisfying the room temperature. During the timer setting, the timer can be reset by pressing TIMER and pressing the + or – button. Pressing the SLEEP button cancels the timer mode, and pressing the TIMER button will cancel the sleep mode.
  • Page 21: Accessories Installation

    ACCESSORIES INSTALLATION 1. Caster Installation: Note: The casters must be assembled before using the unit. Tilt the unit minimally to install the casters. 1. Open the accessory box and remove the casters (4). 2. Lift up the unit horizontally 4 to 8” above the ground. 3.
  • Page 22 3. Air exhaust duct THE AIR EXHAUST DUCT MOUNTING MENTOD CAUTION Fix the square end of the exhaust duct to the exhaust terminal of the unit. Put the other end (discharge) to the nearest window. ATTENTION: The length of the air exhaust must be between 19”-78” When mounting, try to keep the air exhaust duct horizontal.
  • Page 23: Window Kit Installation

    WINDOW KIT INSTALLATION Open window or sliding door approximately 5 inches (13 cm). Adjust the length of the window kit to the same length of the window or sliding door. Use two or three panels if necessary and secure panels into place by fastening the 3/4”...
  • Page 24: Maintenance

    MAINTENANCE WARNING We recommend you follow the cleaning and maintenance operations regularly as indicated in the instructions. Unplug the unit before performing any cleaning operations to prevent accidents caused by electrical shock. AIR FILTER If the air filter is clogged with dust the air flow volume is reduced. For this reason, clean the filter regularly.
  • Page 25: Trouble Shooting

    TROUBLE SHOOTING BEFORE CALLING FOR REPARI SERVICE, PLEASE CHECK: PROBLEM CAUSE SUGGESTED SOLUTION The air conditioner does not Not plugged in Plug in correctly. work Defective plug or socket Change the plug or socket Fuse blown Replace fuse Breaker tripped Reset Breaker If problem persists, contact a licensed technician.
  • Page 26: Safety Caution And Special Guideline

    SAFETY CAUTIONS AND SPECIAL GUIDELINES WARNING Avoid direct sunlight as surface discoloration may occur Do not use the unit near water to avoid electrical shock. Do not use near gas appliances, fires, or near flammable liquids. Do not use the unit in the immediate vicinity of a bath, shower, or a swimming pool. OTHER Keep the unit 3”...
  • Page 27: Warranty Statement

    WARRANTY The portable air conditioning system you have purchased carries a limited warranty of one (1) year on parts and five (5) years on the compressor. Labor is not covered under warranty. Please contact your local dealer for additional details. INTERNATIONAL REFRIGERATION PRODUCTS INC.

This manual is also suitable for: