WAC12115R
950-0010-revI
WINDOW
AIR CONDITIONER
INSTALLATION
OPERATION
PRODUCT CODE
420-0015
AND
CATALOG NO.
WAC12230M
WAC12115M
Page 1 of 19
PRODUCT CODE
420-0014
420-0016
1-09-07

Advertisement

Table of Contents
loading

Summary of Contents for Thermal Zone WAC12230M

  • Page 1 WINDOW AIR CONDITIONER INSTALLATION OPERATION CATALOG NO. PRODUCT CODE CATALOG NO. PRODUCT CODE WAC12230M 420-0014 WAC12115R 420-0015 WAC12115M 420-0016 950-0010-revI 1-09-07 Page 1 of 19...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS AIR CONDITIONER SAFETY………………………………………………….….2 INSTALLATION REQUIREMENTS………………………………………………3 ELECTRICAL REQUIREMENTS…………………………………………………4 INSTALLATION INSTRUCTIONS………………………………………………..6 THRU-WALL INSTALLATION INSTRUCTIONS………………………………10 AIR CONDITIONER USE…………………………………………………………12 AIR CONDITIONER CARE……………………………………………………….16 TROUBLESHOOTING………………………………………………………….…16 SPECIFICATIONS…………………………………………………………………18 WARRANTY………………………………………………………………………...19 TECHNICAL SUPPORT IF YOU NEED TECHNICAL SUPPORT, PLEASE CALL (705) 504-8590 BETWEEN THE HOURS OF 8:00 A.M. and 5:00 P.M.
  • Page 3: Installation Requirements

    IMPORTANT SAFETY INSTRUCTIONS WARNING: To reduce the risk of fire, electrical shock, or injury when using your air conditioner, follow these basic precautions: • • Plug into a grounded 3 prong outlet. Do not use an extension cord • • Do not remove ground prong Unplug air conditioner before servicing •...
  • Page 4: Electrical Requirements

    ELECTRICAL REQUIREMENTS Window Installation Window opening measurements: • 27” min to 38” max (68.6 cm to 95.5cm) opening width. • 16 ¼” min. (41.3 cm) opening height. Ground wire must be connected to ground screw located in lower Through-the wall installation right corner of air conditioner when air conditioner is in cabinet.
  • Page 5 This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances.
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS UNPACKING Remove front panel by removing 2 Phillips head screws on both sides of air conditioner. Remove both knobs from control panel Remove ground screw and ground wire from front of air conditioner base. Save ground screw. Remove packaging materials •...
  • Page 7 Attach Side Curtains ______________________________________________ Attach Foam Adhesive Seal _______________________________________________________ Locate provided bag of screws Insert top and bottom of right-hand curtain housing in Attach foam adhesive seal along the bottom of the curtain bottom top and bottom curtain guides on air-conditioner channel.
  • Page 8 Insert one of the #10 x ¾” round-head screws through hole Use a 3/16” drill bit to drill 3 starter holes 3/8” deep and into lower window sash. Insert one of the #10 x ¾” through the 3 holes in the cabinet and into the windowsill. round-head screws through threaded hole in top of curtain.
  • Page 9 ______________________________________________________________________________________________________________________ Complete Installation Position ground wire pointing straight up. Put excess ground wire between coil and air conditioner cabinet NOTE: Handle the air conditioner gently. Make sure the free end of the ground wire is outside of the cabinet. Insert air conditioner into cabinet. REMEMBER: Make sure the free end of the ground wire is outside of the cabinet.
  • Page 10: Thru-Wall Installation Instructions

    __________________________________________________________________________________________________________________ THRU-WALL INSTALLATION INSTRUCTIONS INTRODUCTION This instruction sheet provides guidelines for installing a compact air conditioner through an outside wall. Air Conditioner Dimensions The following figures show the outside dimensions of air conditioner with chassis installed, and dimensions of the outer case with the chassis removed which need to be measured accurately to determine the size of the opening through the wall.
  • Page 11 Framed/Finished Opening (brick veneer or frame wall construction) While operation of all units is similar, controls very from model Placement of Outer Case in Opening to model. Operating Controls section shows control panel of unit Place outer case in opening, flush against one side of opening. purchased and gives detailed information about controls.
  • Page 12: Air Conditioner Use

    __________________________________________________________________________________________________________________ AIR CONDITIONER USE Operating your air-conditioner properly helps you obtain the best possible results. Do not try to operate your air conditioner in the cooling mode when outside temperature is below 65º F (18ºC). The inside evaporator coil This section explains proper air conditioner operation will freeze up, and the air conditioner will not operate properly.
  • Page 13 To set the timer to turn on the air conditioner, changing the _______________________________________________________ TEMPERATURE previous settings: _______________________________________________________ 1. Turn on air conditioner. Press the plus button to raise the temperature. Display shows the temperature control setting. Each time you press or hold the plus 2.
  • Page 14 Starting your Air Conditioner – Rotary Control Model WAC12115M Model WAC12230M 1. Set exhaust control. See “Exhaust Control (on some models)” 2. Select the fan speed. See “Fan Speed”. 3. Set Temperature. See “Temperature”...
  • Page 15 When your air conditioner is operating normally, you may hear sounds such as: Clicking Sound. The water droplets help cool the condenser. Model WAC12230M Air movement from the fan. Clicks from the thermostat cycle Vibrations or noise due to poor wall or window construction.
  • Page 16: Air Conditioner Care

    ______________________________________________________________________________________________________________________ AIR CONDITIONER CARE _______________________________________________________ Cleaning the Front Panel Your new air conditioner is designed to give you many years of dependable service. This section tells you how to clean and care for your air conditioner properly. Call your local authorized dealer for an 1.
  • Page 17 There is excessive heat or moisture (open container cooking, showers, etc.) in the room. Use a fan to exhaust heat or moisture _______________________________________________________ Air conditioner power supply cord trips (Reset button pops out) from the room. Try not to use heat producing appliances during the _______________________________________________________ hottest part of the day.
  • Page 18: Specifications

    SPECIFICATIONS MODEL WAC12115M WAC12115R WAC12230M BTU Cooling 12,000 12,000 12,000 BTU Heating Dehumidification (Pints/Hour) Airflow (cfm) Voltage 115 VAC 115 VAC 208/230 VAC Frequency (Cycles) 60 HZ 60 HZ 60 HZ Amps cooling 14.56 14.56 7.07 Amps Heating Watts Cooling...
  • Page 19: Warranty

    Warranty International Refrigeration Products warrants that the product supplied is free from defects in material and workmanship. This warranty is valid as long as this product is properly handled, installed, operated and serviced in accordance with the Installation and Operating Instructions shipped with this unit, and the warranty card is completed and mailed no later than 30 days after date of purchase.