Sensorless 120-degree conducting control of permanent magnetic synchronous motor (81 pages)
Summary of Contents for Renesas Synergy PK-CLOUD1
Page 1
All information contained in these materials, including products and product specifications, represents information on the product at the time of publication and is subject to change by Renesas Electronics Corp. without notice. Please review the latest information published by Renesas Electronics Corp.
Page 2
Renesas Electronics products, such as safety design for hardware and software, including but not limited to redundancy, fire control and malfunction prevention, appropriate treatment for aging degradation or any other appropriate measures.
General Precautions 1. Precaution against Electrostatic Discharge (ESD) A strong electrical field, when exposed to a CMOS device, can cause destruction of the gate oxide and ultimately degrade the device operation. Steps must be taken to stop the generation of static electricity as much as possible, and quickly dissipate it when it occurs.
Quick Start Guide Renesas Synergy™ Platform R20QS0003EU0110 Synergy Enterprise Cloud Toolbox Rev.1.10 for PK-CLOUD1 Feb 21, 2018 Contents Introduction ..........................2 Prerequisites..........................2 Requirements .......................... 2 About the Demonstration ......................2 Setting up the Hardware ......................3 Setting up and executing the Demonstration ................5 Setting up the PK-CLOUD1 Project ......................
This application package can be used as a reference solution for users to quickly get started on the Synergy Software Package (SSP), Wi-Fi Framework, and Cellular Framework, as well as Ethernet connectivity, and cloud connectivity ™ with different IoT Cloud Providers using the Renesas Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Kit. Prerequisites ®...
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 The major components (see Figure 2) in the embedded application include: • SSP components Wi-fi framework Cellular Framework NetX IP stack Cloud APIs (MQTT/TLS) Console framework •...
Page 7
Notes: • After connecting the PK-CLOUD1 device to your computer, if it does not appear as a device, follow the instructions given on the Renesas Synergy Knowledge Base web page for manually assigning the SEGGER CDC UART driver to the “EL Composite Device” in Windows.
PMOD adapter. Setting up and executing the Demonstration ™ The main components of the demonstration are the Renesas Synergy Enterprise Cloud Toolbox Dashboard and the S5D9 Synergy MCU device built on PK-CLOUD1 kit. See Synergy Enterprise Cloud Toolbox Application Note for instructions to build and install (flash) the embedded application onto the PK-CLOUD1 device and run the Synergy Enterprise Cloud Toolbox Dashboard code.
Page 9
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 **************************************************************************** Synergy Enterprise Cloud Toolbox Version 1.1.0, Released-2018/02/15 Build 3.0 **************************************************************************** Initializing sensors: done Initializing data flash: done > Figure 5 Sensor initialization and command prompt Note: You can press Enter at any time to return to the Main Menu.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Setting up PK-CLOUD1 for Wi-Fi Configure the Wi-Fi interface as an active interface using command: cwiz Figure 8 Setting Wi-Fi interface as an active interface The cwiz command displays all supporting network interfaces. To activate the Wi-Fi interface, enter command 2. Now enter the SSID, passphrase, and security type associated with the network at each prompt.
Page 11
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Figure 10 shows an alternate method to set up Wi-Fi as the network interface, where you provision the Wi-Fi module for the first time on the network using the command wifi <SSID><KEY><SECURITY TYPE>.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Setting up PK-CLOUD1 for Ethernet To use the Ethernet as the network interface, enter the command: cwiz Figure 13 Setting the Ethernet interface as an active interface and the IP configuration The cwiz command displays supported network interfaces.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Setting up the Cellular network interface for PK-CLOUD1 To use Cellular as the network interface, use the command cwiz: Figure 16 Cellular module provisioning information The cwiz command displays supported network interfaces. To activate Cellular, enter command 3. Now enter the APN, Context ID, and PDP type associated with the network at each prompt.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Note that the valid Context ID is from 1 to 5 and the PDP can be either IP or IPV4V6. The APN, Context ID, and PDP types vary across cellular service providers. Contact your cellular service provider to obtain the correct values for these parameters.
Page 15
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Figure 21 Sign up screen Fill in the sign-up form and click on Accept and Continue. The hints given when you enter information in each field specify any constraints. For example, Full Name and Company information may contain spaces in between text, whereas space is not a valid input for Phone and Password fields.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Adding a Device to the Synergy Enterprise Cloud Toolbox Dashboard After logging in, click Add Device from the Device Management view to display an Add A Device view. Figure 22 Adding a device The following steps guide you as you add a device: 1.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 The next step is to configure the device with the registered username (email) and password. Configuring User Credentials for PK-CLOUD1 Switch to the device for the CLI and configure user email address and password, using the commands: user, email_id, and password.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Provisioning for PK-CLOUD1 To provision the device with the connection credentials and details of the IoT Cloud Provider’s platform, do the following: Execute the command: boot Figure 24 Device bootstrapping The boot command triggers a request to the Dashboard REST API to pass the configured user credentials and device unique ID.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 6.10 Remote Monitoring on the Synergy Enterprise Cloud Toolbox Dashboard Switch to the Dashboard view in the browser. Navigate to the Remote Monitoring tab to view the real-time device status and the sensor data.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 6.12 Changing IoT cloud providers Devices bootstrapped with the Dashboard can be switched between the supported IoT Cloud Providers. In the following example, the device is currently provisioned for the Azure IoT platform. Use the following steps to change the IoT Cloud Provider to AWS: Login to the Synergy Enterprise Cloud Toolbox Dashboard.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 6.13 Resetting the system from the Synergy Enterprise Cloud Toolbox Dashboard The reset feature is available only to the admin user. Using the reset functionality, the admin user can delete all devices and users from the system.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 6.14 Notes and Limitations It is mandatory that user compiles the IAR project in a different folder from where the e2studio project has been compiled. After a network interface has been selected, if you want to change it, the system MUST be power-cycled and a new network interface selected.
Sometimes the service provider associates the IMEI and SIM numbers together therefore interchanging the SIM with different cellular hardware modules may not work. • Synergy Enterprise Cloud Toolbox requires the use of the PK-Cloud1 kit (not sold commercially). Contact Renesas sales to get one. •...
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 For Jio SIM in India, use the command cell internet 1 IP For Verizon SIM in USA, use the command cell 463b012d31363846394e04a551215454INTERNET 3 IPV4V6 For Vodafone in Europe, use the command cell internet 1 IP Appendix —...
Page 25
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 For instructions on how to build and flash the software on the device using e studio ISDE and IAR EW for Synergy, see the Application Note provided with the Synergy Enterprise Cloud Toolbox.
Renesas Synergy™ Platform Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Website and Support Support: https://synergygallery.renesas.com/support Technical Contact Details: • America: https://www.renesas.com/en-us/support/contact.html • Europe: https://www.renesas.com/en-eu/support/contact.html • Japan: https://www.renesas.com/ja-jp/support/contact.html All trademarks and registered trademarks are the property of their respective owners. R20QS0003EU0110 Rev.1.10...
Revision History Description Rev. Date Page Summary 1.00 Sep 29, 2017 — Initial release 1.08 Jan 11, 2018 — Changed PK-S5D9 to PK-CLOUD1 and updated procedures. 1.10 Feb 21, 2018 — Updated the following items in the document: — Screenshots throughout —...
Page 28
Synergy Enterprise Cloud Toolbox for PK-CLOUD1 Quick Start Guide Publication Date: Rev.1.10 Feb 21, 2018 Published by: Renesas Electronics Corporation...
Page 29
SALES OFFICES Refer to "http://www.renesas.com/" for the latest and detailed information. Renesas Electronics America Inc. 1001 Murphy Ranch Road, Milpitas, CA 95035, U.S.A. Tel: +1-408-432-8888, Fax: +1-408-434-5351 Renesas Electronics Canada Limited 9251 Yonge Street, Suite 8309 Richmond Hill, Ontario Canada L4C 9T3...
Need help?
Do you have a question about the Synergy PK-CLOUD1 and is the answer not in the manual?
Questions and answers