Integrated
PFA7 10
Display Type
Flow rate range
10
1 to 10
l
/min
50
5 to 50
l
/min
11
10 to 100
l
/min
21
20 to 200
l
/min
51
50 to 500
/min
l
Flow rate (
Port
Symbol
size
10
50
b
b
01
1/8
b
b
02
1/4
3/8
03
04
1/2
Specifications
Model
Measured fluid
Detection type
Flow rate measurement range
Minimum setting unit
Real-time flow rate
Note 1)
Display units
Accumulated flow
Operating pressure range
Proof pressure
Pressure loss
Accumulated flow range
Operating temperature range
Linearity
Repeatability
Temperature characteristics
NPN open collector
Switch
Note 2)
output
Output
PNP open collector
specifications
Analog
output
Indicator lights
Response time
Hysteresis
Power supply voltage
Current consumption
Withstand voltage
Insulation resistance
Noise resistance
Vibration resistance
Impact resistance
Weight
Enclosure
Port size (Rc, NPT, G)
Note 1) For digital flow switch with unit switching function. (Fixed SI unit [l/min or l] will be set for switch types without the unit switching function.)
Note 2) The output functions operate only for the real-time flow rate display, and do not operate for the accumulated flow display.
Note 3) Window comparator mode — Since hysteresis will reach 3 digits, keep P1 and P2 apart by 7 digits or more. The minimum setting unit is 1 digit. (Refer to the table above.)
∗ Flow rate units measured under the following conditions: 0°C and 101.3kPa.
For Air
For Air
Digital Flow Switch
Series
How to Order
01
Thread type
Nil
Rc
N
NPT
F
G
Port size
/min)
l
Applicable models
100
200
500
PFA710, PFA750
b
b
PFA711, PFA721
b
PFA751
PFA710
PFA750
1 to 10
l
/min
5 to 50
l
/min
²
-
l
/min, CFM x 10
3kPa (at 50
l
/min)
±1% F.S. or less
±3% F.S. or less (15° to 35°C), ±5% F.S. or less (0° to 50°C)
Maximum load current: 80mA; Internal voltage drop: 1V or less (with load current of 80mA)
Maximum applied voltage: 30V
Maximum load current: 80mA
Internal voltage drop: 1.5V or less (with load current of 80mA)
––
27, 67: Lights up when output is ON
OUT1: Green; OUT2: Red
Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed
150mA or less
1000VAC for 1 min. between external terminal and case
50MΩ (500VDC) between external terminal and case
10 to 500Hz at whichever is smaller: 1.5mm amplitude or 98m/s² acceleration, in X, Y, Z directions for 2 hrs. each
250g (without lead wire)
1/8, 1/4
PFA
27
Wiring specification
Nil
3m lead wire with connector
N
Without lead wire
Output specification
Nil
Output specification
27
NPN open collector 2 outputs
28
NPN open collector 1 output + Analog output (1 to 5V)
PNP open collector 2 outputs
67
68
PNP open collector 1 output + Analog output (1 to 5V)
PFA711
Dry air, N₂
Heater type
10 to 100
/min
l
1% of maximum flow rate
¹
,
-
l
ft³ x 10
0 to 0.5MPa
1.0MPa
3kPa (at 100
/min)
l
0 to 999999
l
0° to 50°C (with no condensation)
±5% F.S. or less
Output voltage: 1 to 5V
Load impedance: 100kΩ or more
27, 67: Lights up when output is ON OUT1: Green; OUT2: Red
28, 68: Lights up when output is ON OUT1: Green; OUT2: None
1 sec. or less
12 to 24VDC (ripple ±10% or less)
160mA or less
1000Vp-p, Pulse width 1µs, Rise time 1ns
490m/s² in X, Y, Z directions 3 times each
IP65
3/8
Unit specification
Nil
With unit switching function
M
Fixed SI unit
Note) Fixed units:
Real-time flow rate:
Accumulated flow:
Applicable models
PFA710, PFA750
PFA711, PFA721, PFA751
PFA711, PFA721, PFA751
PFA710, PFA750
PFA711, PFA721, PFA751
PFA711, PFA721, PFA751
PFA721
PFA751
20 to 200
l
/min
50 to 500
¹
-
/min, CFM x 10
l
10kPa (at 200
l
/min)
30kPa (at 500
±2% F.S. or less
Note 3)
170mA or less
290g (without lead wire)
Note)
l
/min
l
/min
l
/min)
l
1/2
1
Need help?