SMC Networks PFA710 Manual

Hide thumbs Also See for PFA710:

Advertisement

Quick Links

Integrated
PFA7 10
Display Type
Flow rate range
10
1 to 10
l
/min
50
5 to 50
l
/min
11
10 to 100
l
/min
21
20 to 200
l
/min
51
50 to 500
/min
l
Flow rate (
Port
Symbol
size
10
50
b
b
01
1/8
b
b
02
1/4
3/8
03
04
1/2
Specifications
Model
Measured fluid
Detection type
Flow rate measurement range
Minimum setting unit
Real-time flow rate
Note 1)
Display units
Accumulated flow
Operating pressure range
Proof pressure
Pressure loss
Accumulated flow range
Operating temperature range
Linearity
Repeatability
Temperature characteristics
NPN open collector
Switch
Note 2)
output
Output
PNP open collector
specifications
Analog
output
Indicator lights
Response time
Hysteresis
Power supply voltage
Current consumption
Withstand voltage
Insulation resistance
Noise resistance
Vibration resistance
Impact resistance
Weight
Enclosure
Port size (Rc, NPT, G)
Note 1) For digital flow switch with unit switching function. (Fixed SI unit [l/min or l] will be set for switch types without the unit switching function.)
Note 2) The output functions operate only for the real-time flow rate display, and do not operate for the accumulated flow display.
Note 3) Window comparator mode — Since hysteresis will reach 3 digits, keep P1 and P2 apart by 7 digits or more. The minimum setting unit is 1 digit. (Refer to the table above.)
∗ Flow rate units measured under the following conditions: 0°C and 101.3kPa.
For Air
For Air
Digital Flow Switch
Series
How to Order
01
Thread type
Nil
Rc
N
NPT
F
G
Port size
/min)
l
Applicable models
100
200
500
PFA710, PFA750
b
b
PFA711, PFA721
b
PFA751
PFA710
PFA750
1 to 10
l
/min
5 to 50
l
/min
²
-
l
/min, CFM x 10
3kPa (at 50
l
/min)
±1% F.S. or less
±3% F.S. or less (15° to 35°C), ±5% F.S. or less (0° to 50°C)
Maximum load current: 80mA; Internal voltage drop: 1V or less (with load current of 80mA)
Maximum applied voltage: 30V
Maximum load current: 80mA
Internal voltage drop: 1.5V or less (with load current of 80mA)
––
27, 67: Lights up when output is ON
OUT1: Green; OUT2: Red
Hysteresis mode: Variable (can be set from 0), Window comparator mode: 3-digit fixed
150mA or less
1000VAC for 1 min. between external terminal and case
50MΩ (500VDC) between external terminal and case
10 to 500Hz at whichever is smaller: 1.5mm amplitude or 98m/s² acceleration, in X, Y, Z directions for 2 hrs. each
250g (without lead wire)
1/8, 1/4
PFA
27
Wiring specification
Nil
3m lead wire with connector
N
Without lead wire
Output specification
Nil
Output specification
27
NPN open collector 2 outputs
28
NPN open collector 1 output + Analog output (1 to 5V)
PNP open collector 2 outputs
67
68
PNP open collector 1 output + Analog output (1 to 5V)
PFA711
Dry air, N₂
Heater type
10 to 100
/min
l
1% of maximum flow rate
¹
,
-
l
ft³ x 10
0 to 0.5MPa
1.0MPa
3kPa (at 100
/min)
l
0 to 999999
l
0° to 50°C (with no condensation)
±5% F.S. or less
Output voltage: 1 to 5V
Load impedance: 100kΩ or more
27, 67: Lights up when output is ON OUT1: Green; OUT2: Red
28, 68: Lights up when output is ON OUT1: Green; OUT2: None
1 sec. or less
12 to 24VDC (ripple ±10% or less)
160mA or less
1000Vp-p, Pulse width 1µs, Rise time 1ns
490m/s² in X, Y, Z directions 3 times each
IP65
3/8
Unit specification
Nil
With unit switching function
M
Fixed SI unit
Note) Fixed units:
Real-time flow rate:
Accumulated flow:
Applicable models
PFA710, PFA750
PFA711, PFA721, PFA751
PFA711, PFA721, PFA751
PFA710, PFA750
PFA711, PFA721, PFA751
PFA711, PFA721, PFA751
PFA721
PFA751
20 to 200
l
/min
50 to 500
¹
-
/min, CFM x 10
l
10kPa (at 200
l
/min)
30kPa (at 500
±2% F.S. or less
Note 3)
170mA or less
290g (without lead wire)
Note)
l
/min
l
/min
l
/min)
l
1/2
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the PFA710 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks PFA710

  • Page 1 /min) Output specification Applicable models Port Symbol Applicable models size PFA710, PFA750 NPN open collector 2 outputs PFA711, PFA721, PFA751 PFA710, PFA750 NPN open collector 1 output + Analog output (1 to 5V) PFA711, PFA721, PFA751 PFA711, PFA721 PFA710, PFA750...
  • Page 2 Series Sensor Unit Construction PFA710, PFA750 PFA510, PFA550 Parts list Description Material Attachment Seal Mesh Stainless steel Body Sensor Flow direction PFA711, PFA721, PFA751 PFA511, PFA521, PFA551 Parts list Material Description Attachment Seal Spacer Stainless steel Mesh Body Sensor Flow direction...
  • Page 3 For Air Series Digital Flow Switch Flow Rate Setting Setting procedure Key lock Manual flow mode rate setting Even if button is pressed Set the flow rate that during operation, mode performs switch output. will not be switched. Initial setting Initial setting: Sets the display mode (real-time flow rate/accumulated...
  • Page 4 Series Flow Rate Setting Flow rate setting mode (manual) Set Value Input Manual Mode Setting the first (1) Mode (Manual) Value for OUT 1 Setting Press the SET button. OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 Press the SET button. Press the SET button when Set the first (1) value for OUT1.
  • Page 5 For Air Series Digital Flow Switch Other functions Accumulated flow function Key lock mode • • Prevents incorrect operations of the button control. Start of Start of Accumulation Key Lock Function OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 OUT1 OUT2 Press the SET button to complete Start accumulation.
  • Page 6 Series Integrated Display Type for Air Dimensions: Internal circuits and wiring examples PFA710, PFA750 Brown Black LED Green OUT1 – White 24VDC LED Red OUT2 Blue PFA7 -27 (-M) FLOW SWITCH Brown OUT1 OUT2 DOWN FOR AIR OUT1 Black LED Green 2-Port size –...

This manual is also suitable for:

Pfa seriesPfa750Pfa711Pfa721Pfa751