Advertisement

Quick Links

QR code for user manual
Version 2.4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Eminere Remote 1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Anolis Eminere Remote 1

  • Page 1 QR code for user manual Version 2.4...
  • Page 2: Table Of Contents

    Eminere Remote Table of contents 1. Safety instructions ..............................3 2. Fixture exterior view ..............................5 3. Installation .................................. 5 3.1 Mounting the fixture ............................5 3.2 Connection to driver ............................. 5 3.3 Wiring of the junction box ............................ 8 3.4 Example of Control panel in RDM manager ......................
  • Page 3: Safety Instructions

    Eminere Remote FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR Eminere Remote ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure safe operation, it is absolutely necessary for the user to follow the safety instructions and warnings written in this manual.
  • Page 4 Eminere Remote Refer servicing to qualified service personnel. The product (covers and cables) must not be exposed to a high frequency electromagnetic field higher than 3V/m. Immunity of the equipment is designed according to the standard EN 55035 Electromagnetic compatibility of multimedia equipment - Immunity requirements Emission of the equipment complies with the standard EN55032 Electromagnetic compatibility of multimedia equipment –...
  • Page 5: Fixture Exterior View

    Eminere Remote 2. Fixture exterior view 1. Transparent glass cover 2. Gore tex valve 3. Cable gland M20 (IN) 4. Housing 5. Mounting brackets 6. Cable gland M20 (OUT) 7. Junction box 3. Installation 3.1 Mounting the fixture The Eminere Remote can be arranged in any orientation on a flat, non-flammable surface by means of two mounting brackets (5) which can be tilted by 30°.
  • Page 6 Eminere Remote Example of connection The table below states max. number of Eminere Remote modules connected to the E-box Remote/E-box Remote Basic. Max. number of Emineres Remote connected to the E-box Remote/E-box Remote Basic Cable length * Eminere Eminere Eminere Eminere Remote 1 Remote 2...
  • Page 7 Eminere Remote Example: Total cable length=L1+L2+L3+L4 Max. number of Eminere Remote modules connected to the one output of the E-box Remote/E-box Remote Basic is stated in the following table. Max. number of Emineres Remote connected to the one output of the E-box Remote/E-box Remote Basic Eminere Eminere...
  • Page 8: Wiring Of The Junction Box

    Eminere Remote 3.3 Wiring of the junction box 1. Unscrew the four screws (9) on the cover (8) of the junction box (7), remove the cover (8) and the gasket (10). 2. Remove the end cap (11) from cable glands before passing cables throw cable glands M20 (3,6). The cable glands M20x1.5 can be used for cables of a diameter of 7-13mm.
  • Page 9 Eminere Remote US version Connector Function LEDs + Data + Data - LEDs - Ground Colour of wire Orange White Black Yellow/Green NOTE: Each line of Emineres Remote connected to the LED output of the E-box Remote/E-box Remote Basic has to be terminated at the last fixture.
  • Page 10 Eminere Remote...
  • Page 11: Example Of Control Panel In Rdm Manager

    Eminere Remote Example of Control panel in RDM manager The software RDM manager is available on the ROBE website (https://www.robe.cz/support), product RUNIT WTX. Green arrow saves changes made in the Control panel to the Eminere Remote.
  • Page 12: Software Update

    Eminere Remote Manufacturer PIDs Wireless unlink - the item is not active for the Eminere Remote. LED calibration 4byte HEX! (RGBW/RGBA) - the item shows 4 bytes of calibration values for calibrated white colours of RGBW(RGBA) Eminere Remote. E.g. CTC channel has to be set to some calibrated white colour (21 DMX-1800K, 66 DMX-2700K, 91 DMX-3200K, 141 DMX-4200K, 211 DMX-5600K, 255 DMX-6500K) otherwise the item shows values "ff ff ff ff"...
  • Page 13: Technical Specifications

    Eminere Remote 4: 80W Optic • Light source: Eminere Remote 1: 12 x high power LEDs Eminere Remote 2: 24 x high power LEDs Eminere Remote 3: 36 x high power LEDs Eminere Remote 4: 48 x high power LEDs •...
  • Page 14 Eminere Remote Dimensions (All dimensions in mm [inch]) Eminere Remote 1 Eminere Remote 2/3/4...
  • Page 15: Cleaning And Maintenance

    •Mounting Bracket 200 RAL 9006 (P/N 10980663) •Mounting Bracket 300 RAL 9011 (P/N 10980524) •Mounting Bracket- Custom length •Shield For Eminere Remote 1 RAL 9011 (P/N 10980518) •Shield For Eminere Remote 2 RAL 9011 (P/N 10980519) •Shield For Eminere Remote 4 RAL 9011 (P/N 10980520) •Cable for Eminere Remote (P/N 13053336)
  • Page 16: Changelog

    Eminere Remote 7. ChangeLog This section summarizes changes in the user manual. Version of Date of issue Description of changes the manual 08/10/2021 Technical specification changed 26/11/2021 Optional accessories changed 01/12/2021 Information about 120 Ohm terminator added 12/01/2021 Procedure Wiring junction box changed 26/01/2022 Marking of conection blocks in junction box changed 07/04/2022...
  • Page 17 DMX protocol DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4; Eminere Inground 2/4; Eminere Remote 1/2/3/4; UVinere 2/4; UVinere Remote 1/2/4 Version: 3.3 (23 modes in total), software version 3.0 and higher Mode/Channels in all Mode 1: RGBW(A)-8bit, Mode 2: RGB 8-bit, Mode 3: full RGBW(A)
  • Page 18 DMX protocol Mode/channels Type of Function Value control (21-1800K, 66-2700K, 91-3200K,141-4200K, 211-5600K, 255- 6500K) Virtual Colour Wheel No function step White 1800 K step White 2700 K step White 3200 K step White 4200 K step 9-10 White 5600 K step 11-12 White 6500 K step...
  • Page 19 DMX protocol Mode/channels Type of Function Value control Shutter/Strobe Shutter closed 0-31 step Shutter open 32-63 step Strobe-effect from slow to fast 64-95 proportional Shutter open 96-127 step Opening pulse in sequences from slow to fast 128-143 proportional Closing pulse in sequences from fast to slow 144-159 proportional Shutter open...
  • Page 20 DMX protocol DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4; Eminere Inground 2/4; Eminere Remote 1/2/3/4; UVinere 2/4; UVinere Remote 1/2/4 Version: 3.3 (23 modes in total) Mode/Channels in all Mode 11: White selection, Mode 12: WW + CW 14-16...
  • Page 21 DMX protocol DMX protocol for: Eminere 1/2/3/4; Eminere Side 1/2/3/4; Eminere Inground 2/4; Eminere Remote 1/2/3/4; Version: 3.3 (23 modes in total) Mode/Channels in all Mode 17: RGBW(A) pixels, Mode 18: RGB pixels, Mode 19: TW pixels, 21-23 Mode 20: PW dimmer pixels...
  • Page 22 DMX protocol Mode/channels Type of Function Value control 0 - 255 Warm White LEDs saturation control (0-100%) proportional Cool White 2-Eminere 2/3/4 0 - 255 Cool White LEDs saturation control (0-100%) proportional Warm White 3-Eminere 3/4 0 - 255 Warm White LEDs saturation control (0-100%) proportional Cool White 3-Eminere 3/4 0 - 255...

This manual is also suitable for:

Eminere remote 2Eminere remote 3Eminere remote 4

Table of Contents