Moxa Technologies MGate 5114 Series Quick Installation Manual
Moxa Technologies MGate 5114 Series Quick Installation Manual

Moxa Technologies MGate 5114 Series Quick Installation Manual

Hide thumbs Also See for MGate 5114 Series:

Advertisement

MGate 5114 Series
Quick Installation Guide
Version 1.3, October 2024
Technical Support Contact Information
www.moxa.com/support
 2024 Moxa Inc. All rights reserved.
P/N: 1802051140013
*1802051140013*

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGate 5114 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Moxa Technologies MGate 5114 Series

  • Page 1 MGate 5114 Series Quick Installation Guide Version 1.3, October 2024 Technical Support Contact Information www.moxa.com/support  2024 Moxa Inc. All rights reserved. P/N: 1802051140013 *1802051140013*...
  • Page 2: Package Checklist

    Overview The MGate 5114 is an industrial Ethernet gateway for Modbus RTU/ASCII/TCP and IEC 60870-5-101/104 network communications. Package Checklist Before installing the MGate 5114, verify that the package contains the following items: • 1 MGate 5114 gateway • 1 serial cable: CBL-RJ45F9-150 •...
  • Page 3: Reset Button

    Color Description When the MGate 5114 acts as a Modbus RTU/ASCII slave: 1. Received an invalid function code The master accessed an invalid register address or coil address 2. Received a framing error (parity error, checksum error) 101* No serial communication with the IEC 60870- 5-101 device Green Normal IEC 60870-5-101 serial communication...
  • Page 4: Hardware Installation Procedure

    Pull-high, Pull-low, and Terminator for RS-485 Beneath the MGate 5114’s top cover, you will find DIP switches to adjust each serial port’s pull-high resistor, pull-low resistor, and terminator. Pull-high Pull-low Terminator resistor resistor 1 kΩ 1 kΩ 120 Ω 150 kΩ* 150 kΩ* –* *Default...
  • Page 5: Pin Assignments

    Pin Assignments Serial Port (Male DB9) RS-422/ RS-232 RS-485 (2W) RS-485 (4W) TxD-(A) – TxD+(B) – RxD+(B) Data+(B) RxD-(A) Data-(A) – – – – – – – – – *Signal ground Ethernet Port (RJ45) Signal Power Input and Relay Output Pinouts Shielded Power Power...
  • Page 6 1. DEMKO Certification number: 13 ATEX 1307610X IEC Certification Number: IECEx UL 13.0051X; 2. Ambient Temperature Range: 0°C to 60°C (for models without suffix –T) -40°C to 75°C (for models with suffix –T only) 3. Certification String: Ex ec nC IIC T3 Gc 4.
  • Page 7 WARNING EXPLOSION HAZARD Do not disconnect the equipment unless the power has been switched off, or the area is known to be nonhazardous. WARNING EXPLOSION HAZARD The substitution of any components may impair suitability for Class 1, Division 2. WARNING EXPOSURE TO SOME CHEMICALS MAY DEGRADE THE SEALING PROPERTIES OF MATERIALS USED IN THE FOLLOWING DEVICE: Sealed Relay Device U21.

Table of Contents