Aeotec aerQ User Manual

Temperature and humidity

Advertisement

11/17/21, 11:31 AM
aërQ Temperature and Humidity Sensor user guide.
Modified on: Tue, 12 Oct, 2021 at 2:38 AM
(https://www.youtube.com/watch?v=G2oRuw7L17s)
Aeotec aërQ Temperature and Humidity Sensor was developed to record ambient values for humidity and temperature to
warn of environment that is ideal for mould growth via Z-Wave communication. It is powered by
(https://www.popp.eu/products/)
(http://aeotec.com/z-wave-gen5)
(https://aeotec.freshdesk.com/a/solutions/articles/6000227919)
(https://aeotec.freshdesk.com/a/solutions/articles/6000227919)
Before purchasing make sure to contact your Z-Wave Gateway/Controller manufacturer to determine if this device is
compatible, typically most Z-Wave gateways will be generically compatible to Switch and Sensor type devices. You can find
a list of known compatible Gateway/Controllers in this link
Familiarize yourself with your aërQ Sensor.
https://help.aeotec.com/support/solutions/articles/6000227918-aërq-temperature-and-humidity-sensor-user-guide-
(https://www.youtube.com/watch?v=G2oRuw7L17s)
Aeotec Gen7
(https://aeotec.com/z-wave-home-automation/z-wave-gen7.html)
technology. The
technical specifications
aërQ user Guide : Aeotec Help Desk
 of aërQ Temperature and Humidity Sensor
can be viewed at that link.
(https://aeotec.com/z-wave-gateways/)
 
.
1/11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the aerQ and is the answer not in the manual?

Questions and answers

Summary of Contents for Aeotec aerQ

  • Page 1 Modified on: Tue, 12 Oct, 2021 at 2:38 AM   (https://www.youtube.com/watch?v=G2oRuw7L17s) (https://www.youtube.com/watch?v=G2oRuw7L17s) Aeotec aërQ Temperature and Humidity Sensor was developed to record ambient values for humidity and temperature to warn of environment that is ideal for mould growth via Z-Wave communication. It is powered by Aeotec Gen7 (https://www.popp.eu/products/) (https://aeotec.com/z-wave-home-automation/z-wave-gen7.html)
  • Page 2 11/17/21, 11:31 AM aërQ user Guide : Aeotec Help Desk Package contents 1x aërQ Temperature and Humidity Sensor 1x Battery typ CR2477H 3V  1x Paper guide 1x Double-sided Tape. Button Functions. The Environment Sensor must support the following button functions. Push Type...
  • Page 3: Quick Start

    2. Place your thumb and index finger on the 2 indented arrows and push in. If attached to a wall - pull the aerQ sensor which will separate it from the bottom hald. If not attached to a wall - use your other hand to grip the bottom half of the sensor and pull the 2 sides apart, the 2 halfs will split apart. ...
  • Page 4: Product Usage

    11/17/21, 11:31 AM aërQ user Guide : Aeotec Help Desk Installation of aërQ Sensor. aërQ Sensor utilizes double-sided adhesive tape to allow you to mount aërQ Sensor onto any flat surface. 1. Place the double-sided adhesive on the bottom of aërQ Sensor 2. Choose a place to stick aërQ Sensor and firmly press down to finish the mounting installation.
  • Page 5: Advanced Functions

    11/17/21, 11:31 AM aërQ user Guide : Aeotec Help Desk Reported sensors. Humidity: +/- 3 % on relative humidity, +/-1 %  Hysteresis Temperature: 0 ... 65 °C +/- 1 Kelvin Dew Point: 0 ... 65 °C +/- 1 Kelvin (calculated from other sensor values) Wireless Reports and Command Class.
  • Page 6: Association Groups

    11/17/21, 11:31 AM aërQ user Guide : Aeotec Help Desk Steps to wakeup aërQ Sensor: 1. Unlatch aërQ Sensor from its mounting base. 2. Tap the button once to wakeup aërQ Sensor. Removing your aërQ Sensor from a Z-Wave network. aërQ Sensor can be removed from your Z-Wave network at any time. You’ll need to use an existing Z-Wave network to do this and the following instructions which will tell you how to do this using your existing Z-Wave Network.
  • Page 7: Configuration Parameters

    Parameter 3: Check interval for minimum change on parameters 1 and 2. ( ZWA039 V2.0 or higher) This value determines how often aerQ Sensor checks for minimum change in temperature or humidity on Parameter 1 and 2 or when the Sensor wakes up by button pressing. Value is set in minutes.
  • Page 8 11/17/21, 11:31 AM aërQ user Guide : Aeotec Help Desk Parameter 4: Periodic Reports. This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there will be no periodic reports sent to the controller. ...
  • Page 9 11/17/21, 11:31 AM aërQ user Guide : Aeotec Help Desk Parameter 8: Humidity Lower Watermark value. This parameter defines a relative humidity.  If the measured temperature drops below this relative humidity a BASIC command is sent into Association Group 5.
  • Page 10 Parameter 16: Check interval for Upper/ Lower Watermark value on Parameter 5 ,6,7 and 8. ( ZWA039 V2.0 or higher) This value determines how often aerQ Sensor checks for upper/lower watermark value in temperature or humidity on Parameter 5 ,6,7 and 8.
  • Page 11 11/17/21, 11:31 AM aërQ user Guide : Aeotec Help Desk Setting Setting Description Description Celsius Fahrenheit Parameter 65: Sensor report after inclusion. (ZWA039 V2.0 or higher) This value determines which sensor report will be sent after the inclusion is complete. Size: 1 Byte, Default Value: 15.

Table of Contents