aerauliqa AD1400B Manual

High flow aair circulator
Hide thumbs Also See for AD1400B:

Advertisement

Available languages

Available languages

Quick Links

Manuale Specifico
IT
Specific Manual
EN
AD1400B
2
9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AD1400B and is the answer not in the manual?

Questions and answers

Summary of Contents for aerauliqa AD1400B

  • Page 1 AD1400B Manuale Specifico Specific Manual...
  • Page 2: Table Of Contents

    Istruzioni Originali AD1400B Circolatore d’aria ad alte portate INDICE 1. AVVERTENZE GENERALI 2. AVVERTENZE PARTICOLARI 3. TIPOLOGIA 4. CARATTERISTICHE PRINCIPALI 5. DATI 6. DIMENSIONI E DISTANZE 7. COMPONENTI 8. INSTALLAZIONE 9. SCHEMI COLLEGAMENTO ELETTRICO 9.1 CTRL-A (accessorio a richiesta) 9.2 CTRL-A2 (accessorio a richiesta) 9.3 COMANDO CON POTENZIOMETRO ESTERNO (non fornito)
  • Page 3: Caratteristiche Principali

    AMCA 230-15 AMCA 230-99 r/min W/(m W/(m 1170 1,40 20551 34917 144,3 29064 49380 102,1 AD1400B (1) Potenza max assorbita / portata max 6. DIMENSIONI E DISTANZE 1382 1273 1190 Ø10 1382 Punti di 1273 1190 sospensione o fissaggio a e r a...
  • Page 4: Componenti

    7. COMPONENTI Pos. Descrizione Q.tà Girante Carcassa Motore 8. INSTALLAZIONE ATTENZIONE: Assicurarsi che l’interruttore generale dell’impianto sia spento prima di qualsiasi operazione di installazione, manutenzione o collegamento elettrico! Il ventilatore deve essere installato ad un’altezza non inferiore a 2,7m dal pavimento sottostante. Il ventilatore dovrà...
  • Page 5 Le catene di sospensione devono essere installate con un angolo di 45° come indicato in fig.I-A. ventilatore inclinerà naturalmente all’indietro durante il funzionamento. Se si usano catene molto lunghe per sospendere l’unità, potrebbe verificarsi un effetto pendolo. In questo caso, devono essere previste delle catene aggiuntive attaccare agli...
  • Page 6: Schemi Collegamento Elettrico

    9. SCHEMI COLLEGAMENTO ELETTRICO • Assicurarsi che la macchina non sia alimentata durante ogni operazione di installazione, manutenzione o servizio! • L’installazione, i collegamenti elettrici e la manutenzione della macchina devono essere fatte da un installatore autorizzato e in accordo con le regole locali. •...
  • Page 7: Comando Con Potenziometro Esterno (Non Fornito)

    9.3 COMANDO CON POTENZIOMETRO ESTERNO (non fornito) MARRONE cavo a 3 fili GIALLO-VERDE GIALLO ROSSO MARRONE POTENZIOMETRO BIANCO +10V cavo a 6 fili ESTERNO BLU 0-10V ≥10kΩ NERO GND (NON FORNITO) 9.4 CTRL-XWS (accessorio a richiesta) MARRONE cavo a 3 fili GIALLO-VERDE CTRL-XWS BLU 0-10V...
  • Page 8: Dichiarazione Di Conformità E Incorporazione

    Ventilatori assiali AD MARCHIO: AERAULIQA MARCHIO: AERAULIQA MODELLI: MODELLI: AD1400A, AD1400B AD1400A, AD1400B sulla base del loro progetto e costruzione come quasi- sulla base del loro progetto e costruzione come quasi- macchine, sono progettati in conformità con I Requisiti macchine immesse sul mercato, sono progettati in Essenziali di Salute e Sicurezza (EHSRs) dell’ALLEGATO I,...
  • Page 9: General Information

    Translated from Original Instructions AD1400B High volume circulation fans INDEX GENERAL INFORMATION 2. PRECUTIONS 3. TYPE 4. MAIN FEATURES 5. DATA 6. DIMENSIONS AND CLEARANCES 7. COMPONENTS 8. INSTALLATION 9. WIRING DIAGRAM 9.1 CTRL-A (accessory on request) 9.2 CTRL-A2 (accessory on request) 9.3 CONTROL WITH EXTERNAL POTENTIOMETER (not supplied)
  • Page 10: Main Features

    AMCA 230-99 power r/min W/(m W/(m 1170 1,40 20551 34917 144,3 29064 49380 102,1 AD1400B (1) max. absorbed power / max. airflow 6. DIMENSIONS AND CLEARANCES 1382 1273 1190 Ø10 1382 Points for 1273 1190 suspension or fixed installation a e r a...
  • Page 11: Installation

    7. COMPONENTS Pos. Description Q.ty Impeller Casing Motor 8. INSTALLATION ATTENTION Make sure that the main supply to the unit is disconnected before performing any installation, service, maintenance or electrical work! The fan must be installed at a height of not less than 2.7m from the floor below. The fan must be installed with sufficient surrounding space for assembly/disassembly, cleaning and maintenance.
  • Page 12 The suspension chains must be installed at an angle of approx. 45° as shown in Fig. I-A. The fan will naturally tilt back under operation. If very long chains are used to suspend the unit, a pendulum effect may occur. In this case, additional chains should be attached to the bottom rear corners to prevent...
  • Page 13: Wiring Diagram

    9. WIRING DIAGRAM • Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintance or electrical work! • The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in accordance with local rules and regulations.
  • Page 14 9.3 CONTROL WITH EXTERNAL POTENTIOMETER (not supplied) BROWN BLUE 3-core cable YELLOW-GREEN YELLOW BROWN EXTERNAL WHITE +10V POTENTIOMETER 6-core cable BLUE 0-10V ≥10kΩ BLACK GND (NOT SUPPLIED) 9.4 CTRL-XWS (accessory on request) BROWN BLUE 3-core cable YELLOW-GREEN CTRL-XWS BLUE 0-10V 6-core cable BLACK GND WHITE +10V...
  • Page 15 AD axial fans BRAND: AERAULIQA BRAND: AERAULIQA MODELS: MODELS: AD1400A, AD1400B AD1400A, AD1400B on the basis of its design and construction as partly on the basis of its design and construction of partly completed machines brought onto the market, is designed...
  • Page 16 Sede operativa/Warehouse-Offices: via Mario Calderara 39/41, 25018 Montichiari (Bs) - Sede legale/Registered office: via Mario Calderara 39/41, 25018 Montichiari (Bs) C.F. e P.IVA/VAT 03369930981 - REA BS-528635 - Tel: +39 030 674681 - Fax: +39 030 6872149 - www.aerauliqa.it - www.aerauliqa.com - info@aerauliqa.it Aerauliqa S.r.l.

Table of Contents