1 Read instructions through completely before proceeding.
2 Follow instructions carefully. Installation contrary to instructions invalidates
warranty.
3 Unit should be accessible for complete removal should background be-
come damaged or should other service be required.
4 Unit should be installed level (using a carpenter's level).
5 Nothing should be fastened to dowel or background.
6 Operating switch(es) packed separately in carton. Do not discard with
packing material.
7 Unit operates on 220V, 50 hz., 1 ph current.
NOTE: Unit has been thoroughly inspected and tested at factory and found to
be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any
responsibility on the part of Draper, Inc. for improper installation or faulty
workmanship at the jobsite.
Hanging Video Conferencing Background
General:
When locating background and checking clearance for unit's operation, remember
background is centered in case. Handle case carefully to protect its finish.
Regardless of mounting method, unit should be positively and securely sup-
ported so that vibration or even abusive pulling on the background will not
cause case to work loose or fall. Installer must insure that fasteners used are of
adequate strength and suitable for the mounting surface chosen.
Suspended Installation:
Suspend units from holes in endcaps as shown. "S" Hooks, chains (or cable)
and turnbuckles should be provided by installer. "S" Hooks should go through
the front holes on the endcaps (see drawing on page 2), and both ends of the
"S" Hooks should be crimped for additional safety. Chains should be attached
to beams or other structural members. Turnbuckles should be adjusted so unit
hangs level.
Wall Installation:
Mount through holes in back of endcaps as shown. Installer should furnish
screws, toggle bolts, molly bolts, nylon or lead anchors as required.
Wall Installation with 15 cm Extension Brackets:
Mount the brackets (not included—see diagram on page 2) using hardware
recommended for "Wall Installation" (above). Then, suspend the unit from the
front holes with "S" Hooks (as in "Suspended"). For added safety, be sure to
crimp both ends of the "S" Hooks so the unit cannot come off. For a more rigid
installation, mount the unit from the back holes to the front of the bracket by
using the screws and nuts provided with the brackets.
Wall or Ceiling Installation with Optional Floating Brackets:
Optional Floating Brackets should be located on studs or joists. The bracket
then attaches at any almost any point along the case. For details, see separate
instruction sheet that ships with the Floating Wall Bracket.
Recessed Installation:
Recess should permit access for removal of unit if necessary. Unit may be
mounted as in suspended or wall installation.
Electrical Connections
Unit operates on 220V, 50 hz., 1 ph current. Duty cycle: On 28 seconds/Off 4
minutes.
Junction box is located inside left endcap and coverplate is secured to endcap
with two screws which may be removed with a Torx-head or small straight-
blade screwdriver. Junction box contains brown, black and blue pigtail leads
and green internal ground wire, per wiring diagram on reverse.
Unit is shipped with internal wiring complete and control switch(es) fully boxed.
Wire connecting unit to switch(es) and switch(es) to power supply should be
furnished by installer. Please Note: Unit must be installed in accordance with
the requirements of the Local Building Codes, the Canadian Electrical Code
(CEC), CAN/CSA C22.1 and the National Electric Code (NEC), NFPA 70. An
appropriate disconnect device shall be provided as part of the building installa-
tion. Please Note: Do NOT wire motors in parallel.
All operating switches should be "off" before power is connected.
Plug-in power cord option available with built-in low voltage motor.
Copyright © 2015 Draper Inc.
Form VCBTarga220V_Inst15
Installation/Operating Instructions
Caution
Printed in U.S.A.
For Reconfiguration/Conversion of Non-detachable Power Cord to
Field Wiring for Models TAR-28, TAR-29 and TAR-30 Only:
1 Disconnect cord plug from outlet.
2 Remove junction box cover.
3 Disconnect wire nuts from black, white and green wires.
4 Remove power cord and strain relief from unit.
5 Connect the black motor wire to "hot" supply wire.
6 Connect white motor wire to "neutral" supply wire.
7 Connect green/yellow wire to "ground" supply wire.
8 Replace junction box cover.
Optional Floating Mounting Bracket
Before operating unit remove tape securing background and dowel to roller. If
background hangs out of case 203-228 mm, tape has probably been broken
by rough handling in shipment, allowing it to "unwrap" one turn about the roller.
Manually wrap back around the roller without turning the roller itself.
220V SINGLE STATION CONTROL—3-position UP-OFF-DOWN switch
permits operation to be stopped at any point. Factory adjusted limit switches
automatically stop background when fully down or fully up.
220V MULTIPLE STATION CONTROL—(Not CE Approved) Switches are
similar in appearance to 220V Single Station Control. Background stops when
switch is released and may be restarted in either direction. Factory adjusted
limit switches stop background automatically when fully down or fully up.
24V MULTIPLE STATION CONTROL—Three-button UP-STOP-DOWN
switches stop at any point desired, operate in any sequence. Factory adjusted
limit switches automatically stop background when fully down or fully up.
Installer should incorporate an all-pole disconnect in the fixed wiring.
KEY OPERATED SWITCHING—Two kinds of key-operated switches are
optionally available with this unit. 1 The key-operated power supply switch
controls power to the unit and switches. When it is "off", the switches will not
operate unit. Key may be removed from the switch in either "on" or "off" position.
2 A three-position key switch permits the unit to be operated directly by key. In
this case, the unit's operator must always have a key.
RS232/Ethernet—Serial communication and network communication optionally
available with wall switches, RF or IR remote.
Plug & Play
—Provided with handheld IR remote control transmitter and 3m
TM
cord. No wiring necessary except to connect to RS232. Unit is equipped with
a handheld remote or 3-position operating switch (see below). Three positions
(up-off-down) permit operation to be stopped at any point. Factory adjusted
limit switches automatically stop unit when fully down or fully up.
If you encounter any difficulties installing or servicing your VCB Targa, call your
dealer or Draper Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142.
Operation

Advertisement

loading
Need help?

Need help?

Do you have a question about the VCB Targa 220V and is the answer not in the manual?

Questions and answers

Summary of Contents for Draper VCB Targa 220V

  • Page 1 Optional Floating Mounting Bracket be operating properly prior to shipment. These instructions are meant as a guide only. They do not imply any responsibility on the part of Draper, Inc. for improper installation or faulty workmanship at the jobsite. Hanging Video Conferencing Background General: When locating background and checking clearance for unit’s operation, remember...
  • Page 2 Any adjustment of these limits could void the warranty. of the screen. Any adjustment of these limits could void the warranty. Please check with Draper prior to resetting screen limits. Please check with Draper prior to resetting screen limits.
  • Page 3 220V VCB Targa by Draper Page 3 of 4 Optional Ceiling Opening Trim Kit Methods of Installation (Dims-Side View) Crimp Fasteners for wall mounting Crimp S Hooks for by others. suspended installation. 22 mm hole for electrical connection. Mounting angle and hardware by others.
  • Page 4 VCB Targa by Draper Page 4 of 4 Wiring Diagrams (Standard and Quiet Motors) Wiring Diagrams—Plug & Play 220V Motor (Low Voltage Control Built Into Motor) Please Note: Do not wire motors in parallel. Single Station Control Single Station Control...