Page 2
Medical app to pump smarter by controlling your setting and logging your sessions. All Motif Medical® products purchased from authorized retailers come with a manufacturer’s warranty stating that product will be free from defects in workmanship and materials; for 2-years on double-elec- tric breast pumps, for 1-year on internal batteries, and for 90-days on breast pump parts.
Page 4
Sterilization and Cleaning Silicone Insert Sizing Understanding Size Test Your Silicone Insert Size Determining the Right Fit Operating Your Breast Pump Assembling The Motif Aura Pump Turning On/Off The Motif Aura Pump How to Use the Motif Medical App Warning: Threats BLE...
Page 5
10. Using Your Motif Aura Pump 10.1 Pumping Guide 10.2 Getting Ready to Pump 10.3 Aligning the Silicone Insert 10.4 Expressing Your Milk 10.5 After Pumping 10.6 Storing Breast Milk Troubleshooting 11.1 Troubleshooting Solutions 11.2 Disposal 11.3 When to Replace Parts 12.
Page 7
2. Highlights Designed to fit in your bra, the Motif Aura is hands-free, powerful and discreet. Wearable Breast Pump Light-up Display No need to bother with messy Suction level, timer, and battery cords and tubing. Simply put on level can be easily viewed on the...
Page 8
3. Intended Use (Indications of Use) The Motif Aura Double Electric Breast Pump is intended for use by lac- tating women to express and collect breast milk. The Motif Aura can be used as a single or double pump and is only intended for personal use.
Page 9
Date of manufacturer Serial number Manufacturer’s catalog number Refer to instruction manual Ingress protection IP22 Battery State Transport / Storage Humidity Operation Humidity To use Temperature Storage Temperature Operating Pressure Transport / Storage Pressure THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 10
4. SYMBOLS Fragile Do not pile This way up Keep Dry Good Manufacturing Practice Logo Type BF applied part This product should not be mixed with other commercial waste for disposal Power Increases level of suction Decreases level of suction...
Page 11
• Never operate this product if it has a damaged cord or plug, it is not working properly, or if it has been dropped or damaged, or dropped into water. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 12
If damage is found, immediately discontinue use of power adapter or battery pack and call customer service. • The Motif Aura should not be positioned so that it is difficult to operate the power adapter. Warning: To avoid health risk and reduce the risk of injury •...
Page 13
Bottles and component parts may become damaged if mishandled, e.g. dropped, over- tightened or knocked over. • Take appropriate care in handling bottles and components. • Do not use the breast milk if bottles or components become damaged. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
While unpacking the box, make sure all of the following components are enclosed. Wearable Breast Pump, Silicone Inserts: 21 mm, 24 mm Motif Medical® Motif Aura (2) & 28 mm (2) Diaphragm (2) Bottle Nipple (2) Breast Shield: 29 mm (2)
Page 15
• Full resupply kit with replacement parts • 15 mm, 17 mm & 19 mm Silicone Inserts • Individual parts Find replacement parts and additional supplies for the Motif Aura at: motifmedical.com/replacement-supplies/ THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
6. PARTS 6.2 Buttons and Features BUTTON CONTROL Power Button Decrease Increase Vacuum Vacuum (suction) (suction) Level Level DISPLAY Wireless Connection Indicator Battery Status Timer/Level Display...
Two bars lamp, third bar flashes It is recommended to charge the battery as soon as battery gets to 0% - 30%. If the battery dies, your Motif Aura will automatically shut down. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 18
6. PARTS Power Button Turns pump ON and OFF. When the pump is ON, this will start the last stored setting Increase Button Increases vacuum (suction) level during the Massage and Expression modes. Decrease Button Decreases the vacuum (suction) level during the Massage and Ex- pression modes.
Page 19
The suction (vacuum) level refers to the suction strength; this is mea- sured in millimeters of mercury (mmHg). When you are using your Motif Medical® Motif Aura, you will usually find that expressing is most effec- tive on the highest suction level that you are comfortable with.
7. Disinfection and Cleaning Clean and sanitize the parts before using your pump for the first time • Diaphragms • Nipples • Breast shields • Valves • Bottles, rings, caps Disinfection Instructions 1. If parts have been used previously, follow cleaning instructions first.
Page 21
It is not recommended to wash and dry Motif breast pump parts in the dishwasher. There is no standard temperature for dishwashers and some may warp parts. Parts damaged in the dishwasher are not covered under warranty. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 22
7. STERILIZATION AND CLEANING After Every Use 1. Thoroughly wash your hands before handling each breast pump component. 2. Disassemble each part that comes into contact with breast milk including the valve, bottle, bottle nipple, silicone insert, bottle screw, and bottle cap. 3.
Page 23
You may need to try more than one size to find the most comfortable and effective fit. Areola Example: Nipple If your nipple diameter measures 16 mm your breast shield sizing range would be Measure: 16mm -19mm. *1 cm = 10 mm Nipple Base THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 24
8. BREAST SHIELD SIZING 8.2 Test Your Silicone Insert Size See below for the recommended breast shield size based on your measurements. Most moms find that adding 0-3mm to their nipple measurement results in a comfortable and effective flange fit. TEST YOUR FLANGE SIZE CHART BREAST SHIELD SIZE Flange...
Page 25
How to wear the Motif Aura with a pumping bra Place the breast pump on your breast, underneath your bra. Adjust the length of the bra straps to make suction more comfortable.
Page 26
9. Operating Your Breast Pump 9.1 Assembling The Motif Aura Pump 1. Wash hands before touching breast pump components. 2. Use the USB-C cable to charge. • Can be used with a standard 5V phone charger. • Connection port is on the front side of the pump.
Page 27
LCD screen. If the breast pump remains unused for a long period of time, make sure that the battery is fully charged before use. Unplug the power adapter from the breast pump immediately after you are finished charging your device. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 28
9. OPERATING YOUR BREAST PUMP 9.3 How to Use the Motif Medical App 1. Search and install the Motif Medical App to the smart phone, available from the [Play Store] or [App Store]. • The App is compatible with the following versions, IOS 11 and OS Android 5.0, or higher.
Page 29
Expression Mode: 6~12 levels) Keep track of your pump sessions by inputting the amount of breast milk expressed and the duration of use. Unit of measure can be configured to mL or Oz. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 30
9. OPERATING YOUR BREAST PUMP Alarm Mode Keep up with each pump session by setting an alarm to notify the next session directly on your smart phone. Alarm can be set with a specific time or use the periodic alarm to set the next session in 5 minute intervals.
Page 31
• Is the Motif Aura is on? • Is there enough battery charge? • Is your smartphone near the Motif Aura pump? • Please check the situation above and reconnect the product by touching the “Reconnect” on the top right of the app screen.
Page 32
9. OPERATING YOUR BREAST PUMP 9.4 Warning: Threats of BLE BLE provides a lot advantages and convenience to users but it does come with risk. Bluetooth® technology and associated devices are susceptible to general wireless networking threats, such as denial of service attacks, eavesdropping, Man-in-the-middle (MITM) attacks, message modification, and resource misappropriation, and are also threatened by more specific Bluetooth®...
Page 33
Due to the proximity required for Bluetooth® connection, users can move the device to a new location to prevent the attack from happening. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 34
9. OPERATING YOUR BREAST PUMP Tips on Safe Bluetooth® Usage After controlling the breast pump with Bluetooth® function, use the following tips to help keep your Bluetooth®-enabled device secure. 1. Turn on ‘discoverable’ mode when you don’t use it. The ‘discoverable’...
Page 35
• Express milk from each breast for 10-15 minutes. It is recommended to pump frequently rather than pumping for a long duration. (Every 2 - 3 hours, 8 times a day.) THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 36
10. USING YOUR MOTIF AURA PUMP 10.2 Getting Ready to Pump 1. Check to see if you are using the correct size breast shield. See chapter 8 Breast Shield Sizing for more details. 2. Wash hands thoroughly. 3. Connect your assembled collection kit to the tubing port on your breast pump.
Page 37
If you are unsure about silicone insert sizing, please contact a healthcare professional or Motif Medical® representative who can help you get a proper fit. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
1. Press the POWER button to start pumping. • After first use, the Motif Aura will automatically remember your last settings for your next pumping session. 2. Adjust the suction (vacuum) level and mode by pressing the INCREASE button and DECREASE button to find a comfortable setting.
Page 39
1. Twist the diaphragm assembly off the breast shield. 2. Remove the breast shield from the milk collection bottle and close the bottle tightly with the bottle cover and bottle disk, and store safely. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
10. USING YOUR MOTIF AURA PUMP 10.6 Storing Breast Milk When storing breast milk in a milk storage bag, make sure to only use non-toxic markers when writing on the bag. STORAGE LOCATIONS / TEMPERATURES Source: CDC.gov Room Freezer Temperature Refrigerator 0°F (-18°C)
Page 41
7. After thawing, milk should be stored in the refrigerator for no more than 24 hours. 8. Never refreeze thawed milk. Throw away previously frozen milk that is not used within 24 hours. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
11. Troubleshooting 11.1 Troubleshooting Solutions Below you will find general conditions that may occur with your Motif Aura and corresponding troubleshooting solutions. Possible Condition Causes Checks Solutions Check if they are Disassemble and Valve properly connected properly reas- suction to silicone insert.
Page 43
Wipe the main body with a clean dry cloth and store it in a warm dry area for about 12 hours. If you need additional help troubleshooting your breast pump, please reach out to the Motif Medical® Customer Service Department. You can access them online at motifmedical.com via chat, through email at hello@motifmedical.com or by phone at...
Page 44
11. TROUBLESHOOTING 11.2 Disposal Please send components that are no longer used to Motif Medical® or properly dispose of the device in accordance with local, state, and federal regulations. As electrical and electronic equipment, the device must be disposed of according to a specialized procedure...
Page 45
• They need to be replaced between 3 to 6 months depending on use. • If you see any tearing, warping, rips, or discoloration then it’s time to replace them. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 46
11. TROUBLESHOOTING Replacing your Silicone Inserts Your silicone inserts will collect residue, can crack, or become discolored over time depending on how often you pump. • They should be replaced every 6 months. • However, keep an eye out for any cracks, tears, or warping because that could indicate that need to be replaced sooner.
Temperature Humidity Pressure Air pressure 700 to 1,060 hPa Transport and Storage Conditions Ambient temperature -4 to 122°F Relative humidity 20 to 95% Temperature Humidity Pressure Air pressure 500 to 1,060 hPa THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
13. Product Information The Motif Aura breast pump is intended to be used in a home environment and is EMC-tested in conformity with the requirements of the standard IEC 60601-1-2:2014 Edition according to clause 7 and 8.9. The breast pump needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in these instructions for use.
Page 49
Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
13. PRODUCT INFORMATION 13.1 Electromagnetic Compatibility Basic EMC standard or Port Test level/ Phenomenon test method tested requirement Mains terminal CISPR 11:2015 AC Mains Group1, Class B disturbance +A1:2016+A2:2019, voltage EN 55011:2016/A2:2021 Group 1, Class A Radiated CISPR 11:2015 Enclosure Group1, Class B disturbance +A1:2016+A2:2019, EN 55011:2016/A2:2021...
Page 51
WARNING: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the motif AURA including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
Page 52
13. PRODUCT INFORMATION 13.2 Test Standards and Results EN 300 328 V2.2.2 Clause Test Items Results Remark 4.3.1.2 or RF output power Note1 4.3.2.2 4.3.2.3 Power Spectral Density Note1 4.3.1.3 or Duty Cycle, Tx-sequence, Tx-gap Note1 4.3.2.4 4.3.1.4 Accumulated Transmit Time, Frequency Note1 Occupation &...
CISPR 11 to cause any interference in nearby electronic equipment- Mains terminal disturbance voltage Group 1 Class B The Motif Aura are suitable for use in all CISPR 11 establishments, including domestic Harmonic current establishments and those directly Complies IEC61000...
13. PRODUCT INFORMATION 13.4 Electromagnetic Immunity This equipment is manufactured to operate in the electromagnetic environment described below The customer or user should verify if this equipment is operated in such environment. Guidance and manufacturer’s declaration-electromagnetic immunity Test of Electronic Standard IEC60601-1-1-2 Electromagnetic Interference...
Page 55
30 A/m 30 A/m (50/60Hz) general value found in according to the domestic or home IEC 61000-4-8 healthcare environment. Note: UT is the AC voltage of the power before using test level THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
Page 56
13. PRODUCT INFORMATION Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
Size: 15 mm x 8 mm x 1.8 mm • Operating Voltage: 1.7V to 3.6V • Operating Temperature: -40 to +85 • RoHS compliant Bluetooth® wireless authentication number KC : R-C-csi-BoT-nL FCC : 2APB6-BOT-NLE521 CE-RED : ETLS180306.0035,ETLS180307.0035 TELEC : 208-180049 THE MOTIF AURA BREAST PUMP | OPERATION MANUAL...
15. FCC Statement Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
The warranty covers manufacturing defects. Motif Medical® cannot re- place a pump part which was damaged by the end user while using the pump. The warranty does not cover lost or stolen items, normal wear and tear to breast pump parts, and items that are misused, abused or improperly stored.
Page 61
Manufactured for: Phone : (844) 272-8390 Email : info@motifmedical.com Motif Medical®, LLC : www.motifmedical.com 8 The Green, Suite 5601 Dover, DE 19901...
Page 62
Thank you for choosing the Motif Aura wearable breast pump! (844) 272-8390 Motif Medical® info@MotifMedical.com 8 The Green, Suite 5601 www.motifmedical.com Dover, DE 19901...
Need help?
Do you have a question about the Aura and is the answer not in the manual?
Questions and answers