Motif Medical Luna - Breast Pump Manual
![]()
Introduction
The Motif Luna Double Electric Breast Pump utilizes a vacuum to express breast milk.
Highlights
- Double Pumping: Expressing from both breasts at the same time saves time and supports milk supply.
- Massage & Expression Modes: Effortlessly switch from Massage to Expression mode, by pressing a single button
- Full Control: Easily adjust suction level and cycles for maximum comfort and an effective pumping session
- Night Light: Choose from three different light levels; great for pumping at night
- Compact Elegance: Innovated with Moms in mind, the Motif Luna is a powerful breast pump designed to blend in with a modern aesthetic
![]()
Please read this document completely and follow the instructions exactly. To prevent personal injury and material damage, please observe the warning and safety information provided in this document. Identification of danger levels:
![]() | Potentially dangerous situation that could result in serious injury. |
![]() | A possibly dangerous situation that could result in slight bodily injury |
NOTICE | Useful information or information you need to know when using this product. |
Intended Use (Indications of use)
![]()
Sharing a breast pump can cause health hazards and void manufacturers warranty
Explanation of Symbols
Symbol | Description |
![]() | Manufacturer |
![]() | Date of manufacture. |
| Serial number. |
| General prohibition sign. |
![caution]() | General warning sign. |
![warning]() | Caution |
| Notice |
![]() | Refer to instruction manual. |
![]() | Type BF applied part. |
![]() | CLASS II equipment. |
![]() | DC |
![]() | Alternating current. |
IP22 | Degree of protection against harmful ingress of water or particulate matter. |
![]() | Temperature limit. |
![]() | Humidity limitation. |
![]() | Atmospheric pressure limitation. |
![]() | Keep dry. |
![]() | Fragile, handle with care. |
![]() | Power |
![]() | Adjust the level of suction or cycle. |
![]() | Changes the operation mode. |
![]() | LED night light. |
Product Description
Components of Device
![Motif Medical - Luna - Components of Device Components of Device]()
Included Components |
- Powered Breast Pump, Motif Medical Luna
|
2x Milk Collection Kit | - Tubing
- Diaphragm Top
- Diaphragm
- Diaphragm Bottom
- 24 mm Breast Shield
- Valve
- Bottle
- Bottle Cap
- Nipple
- Bottle Cover
- Bottle Disk
- Air Flow Port
|
- Adaptor DC12V, 2A
|
Pumping Guide
- Gently massage your breasts or apply warm compresses from the breast toward the nipple before using.
- Express milk from each breast for 10 - 15 minutes. It is recommended to pump frequently rather than pumping for a long duration. (Every 2 - 3 hours, 8 times a day)
Even when you are using the breast pump, it is recommended to breastfeed your baby whenever you can.
Start-up Procedure and Operations
![Motif Medical - Luna - Start-up Procedure and Operations - Step 1 Start-up Procedure and Operations - Step 1]()
![Motif Medical - Luna - Start-up Procedure and Operations - Step 2 Start-up Procedure and Operations - Step 2]()
- Insert the Diaphragm into the Diaphragm Bottom (the component that connects to the breast shield). Ensure that it fits securely and that the Diaphragm edge fits around the rim of the Diaphragm Bottom.
- Connect the Diaphragm Top (the component that connects to the tubing) over the Diaphragm Bottom, and Diaphragm, by snapping-on the Diaphragm Bottom into the rim of the Top Diaphragm.
- Push the valve onto the underside of the Breast Shield.
- Connect the Diaphragm Assembly to the top of the Breast Shield. Use a twisting motion to attach, and later remove, this assembly to avoid damaging it.
- Screw the bottle onto the underside of the Breast Shield.
- Connect the tubing to the Diaphragm Assembly, and connect the other end of the tubing to the Luna. (for single-pumping attach the cap on one Of the air flow ports).
- Attach power adapter to the Luna.
- Plug power adapter into electrical outlet.
Getting Started
While using your Motif Luna maintain an upright position to prevent milk from back flowing
![Motif Medical - Luna - Getting Started - Step 1 Getting Started - Step 1]()
![Motif Medical - Luna - Getting Started - Step 2 Getting Started - Step 2]()
Center the breast shield on your breast so that the nipple is drawn into the flange. It's important that the breast shield is positioned properly before pumping begins to avoid any pain that may be caused by rubbing or twisting of your nipple onto the side of the flange. If double pumping, place the second breast shield in place as well.
While some discomfort may be felt when first using a breast pump, using a breast pump should not cause pain. If you are unsure about breast shield sizing, please contact a healthcare professional or Motif Medical representative who can help you get a proper fit.
![]()
Press the Power button.
The device will power ON, indicated by the screen lighting up. The Luna will begin in Massage mode to help with faster Letdown.
![]()
Press the Mode button to change to Expression mode once your milk starts flowing.
![]()
Adjust suction to preferred comfort level.
![]()
When you wish to stop expressing, first press the Power button, then remove milk collection kit from your breast.
Disconnect the diaphragm assembly from the breast shield.
Remove the breast shield from the milk collection bottle and close the bottle tightly with bottle cover and bottle disk, and store safely.
![Motif Medical - Luna - Getting Started - Step 3 Getting Started - Step 3]()
- Using the Cycle and Suction Settings of your Motif Medical Luna
The Motif Medical Luna will remember your settings automatically for your next session. If you want to start pumping on different settings to those you finished with in your previous session, adjust the settings before you start expressing. - Suction Settings
The suction level on your breast pump refers to the suction strength; this is measured in mmHg. When you are using your Motif Medical Luna, you will usually find that expressing is most effective on the highest suction level that you are comfortable with.
However, it's important not to set suction level so high that it makes you uncomfortable, as the resulting pain will hinder your milk flow. - Massage and Expression Modes
Massage Mode: Suction pattern with fast cycles and low vacuum to help with Letdown and to start milk flowing.
Expression Mode: Suction pattern with slower cycles and higher vacuum to Express milk gently and efficiently
How to Double Pump
![Motif Medical - Luna - How to Double Pump - Step 1 How to Double Pump - Step 1]()
To use in Double-Pump mode remove the plug from the air flow port, and connect the tube from the extra collection kit.
![Motif Medical - Luna - How to Double Pump - Step 2 How to Double Pump - Step 2]()
When changing back to Single-Pump mode make sure to cover the air flow port with the plug.
Cleaning Procedure
- Clean and sanitize all Milk Collection Kit parts before using your pump for the first time, including:
Follow the cleaning and sanitizing instructions.
- Clean the Milk Collection Kit with a clean dish-cloth or soft brush in warm water.
- Rinse the Milk Collection Kit with clear water.
- Place the Milk Collection Kit in boiling water for 5 minutes.
- Gently remove all parts from water with tongs.
- Allow all parts to air dry in a clean area.
- After every use
- Thoroughly wash your hands before handling each breast pump component.
- Disassemble each part that comes into contact with breast milk including the: valve, bottle, bottle nipple, breast shield, bottle disk, and bottle cover
- Rinse each part in cool water to remove milk residue.
- Separately wash each part in the sink with a soft brush or clean dishcloth; OR soak each part in warm soapy water for 5 minutes and thoroughly rinse them; OR separate each part and wash them on the top rack of your dishwasher.
- Dry each part with clean towel and/or allow them to completely air dry on a sanitary surface.
- Wipe the main body with a dry, clean towel after each use.
- Store parts after they completely dry in a clean bag or container. Do not store any damp parts.
How long can I store breast milk?
Storage Locations and Temperatures |
Type Of Breast Milk | Counter top 77ºF or colder (25ºC) (room temperature) | Refrigerator 40ºF (4ºC) | Freezer 0º F or colder (18ºC) |
Freshly Expressed or Pumped | Up to 4 hours | Up to days | Within 6 months is best Up to 12 months is acceptable |
Thawed, Previously Frozen | 1-2 hours | Up to 1 day ( 24 hours) | Never refreeze human milk after it has been thawed |
Leftover from a Feeding (baby did not finish the bottle) | Use within 2 hours after the baby is finished feeding | Never refreeze human milk after it has been thawed |
How do I thaw and use stored breast milk?
- Always make sure to check the date on the milk's container before using. Do not use undated milk, or milk that has been stored too long.
- Thaw frozen milk in the refrigerator or under cool, running water.
- Heat the milk under warm, running water and gently swirl the container to mix the milk.
- If warm water is not available, heat a pan of water in the stove. Once the water is warm, not boiling, remove the pan from the stove and place milk container in the pan. Never warm the milk container directly on the stove.
- Never microwave breast milk because microwave scan cause dangerous hot spots that could burn you or your baby.
- Always test the temperature of the milk on the inside of your wrist before feeding it to a baby. The milk should feel warm, not hot.
- After thawing, milk should be stored in the refrigerator for no more than 24 hours.
- Never refreeze thawed milk. Throw away previously frozen milk that is not used within 24 hours.
LCD Screen
![Motif Medical - Luna - LCD Screen LCD Screen]()
Night Light
![]()
- The LED light appears by pressing the button.
- Select one of three lighting levels.
For Your Safety
PROHIBITION: To reduce the risk of electrocution.
- DO not modify this equipment without authorization Of the manufacturer.
- DO not disassemble or modify the product. The device has no user-serviceable parts.
![]()
To reduce the risk of electrocution.
- Always unplug immediately after use.
- Do not use while bathing.
- Do not place or store product where it can fall or be pulled into a tub or sink.
- Do not place or drop into water or other liquid.
- Do not reach for a product if it has fallen into water. Immediately unplug from electrical outlet.
![]()
To avoid fire, electrocution, or serious burns.
- DO not leave the product unattended when plugged into an electrical outlet.
- Close supervision is necessary when this product is used near children or persons with disabilities.
- Place product out Of reach Of children.
- Use the product only for its intended use as described in this manual. DO not use attachments not recommended by the manufacturer.
- Never operate this product if it has a damaged cord or plug if it is not working properly, Or if it has been dropped Or damaged, Or dropped into water.
- Keep cord away from heated surface.
- Never use while sleeping or when drowsy.
- Never drop or insert any object into any opening or tubing.
- Do not use outdoors, or operate where aerosol (spray) products are being used where oxygen is being administered.
- Always inspect power adaptor and battery pack wires prior to use for damage or exposed wire. If damage is found, immediately discontinue use of power adaptor or battery pack and call Motif Medical Customer Service.
- The Motif Medical Luna should not be positioned so that it is difficult to operate the adaptor.
![]()
To avoid health risk and reduce the risk of injury.
- If you are a mother who is infected with Hepatitis B,Hepatitis C or Human immunodeficiency Virus (H V),pumping breast milk will not reduce or remove the risk Of transmitting the virus to your baby through your breast milk.
- Before each use visually inspect the individual components for cracks, chips, tears, discoloration or deterioration. In the event that damage to the device is observed, please discontinue use until the parts have been replaced.
- This product is the intended for use by a single user only and should not be shared between users.
- DO not drive while pumping.
- Never use while pregnant, as pumping can induce labor.
- Clean and sanitize al parts that come in contact with your breast and breast milk prior to first use.
- Wash all parts that come in contact with your breast and breast milk after every use.
- Inspect all appropriate pump components before each use.
- Do not continue pumping for more than 2 consecutive pumping sessions if no results are achieved.
- Do not thaw frozen breast milk in a microwave or in a pan of boiling water.
- If tube becomes moldy, discontinue use and replace tube.
- If breast milk backup occurs you must clean tube before your next pumping session.
![]()
To avoid minor injury.
- Do not wrap cord around adapter body.
- Use only the power adaptor that comes with the powered breast pump.
- Pump only with the breast pump in an upright position.
- Do not shorten tubing.
- Make sure the voltage of the power adaptor is compatible with the power source.
- Plug the power adaptor into the breast pump first and then into the wall socket.
- Do not use antibacterial or abrasive cleaners/detergents when cleaning breast pump or breast pump parts.
- Never put breast pump motor unit in water or a sterilizer, as you can cause permanent damage to the breast pump.
- Do not attempt to remove the breast shield from your breast while pumping. Turn the breast pump off and break the seal between your breast and breast shield with your finger, then remove breast shield from your breast.
- If pumping is uncomfortable or causing pain, turn the unit off, break the seal between the breast and the breast shield with your finger and remove the breast shield from your breast.
- Plastic bottles and component parts become brittle when frozen and may break when dropped.
- Bottles and component parts may become damaged if mishandled, e.g.dropped, over- tightened or knocked over.
- Take appropriate care in handling bottles and components.
- DO not use the breast milk if bottles or components become damaged.
Phone: (844)272-8390
Email: Info@MotifMedical.com
Web: www.MotifMedical.com
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Motif Medical Luna - Breast Pump Manual
Need help?
Do you have a question about the Luna and is the answer not in the manual?
Questions and answers