Download Print this page
Hide thumbs Also See for Roam:

Advertisement

Quick Links

Motif Roam
Operational
Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the Roam and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Motif Medical Roam

  • Page 1 Motif Roam ™ Operational Manual...
  • Page 2: Introduction

    Compact and portable, the Roam is perfect for pumping anytime, anywhere. All Motif Medical® products purchased from authorized retailers come with a manufacturer’s warranty stating that product will be free from defects in workmanship and materials; for 2-years on breast pumps, for 1-year on internal batteries, and for 90-days on breast pump parts.
  • Page 4: Table Of Contents

    Intended Use (Indications for Use) Symbols Safety Prohibitions, Warnings, and Cautions Parts What’s Included Buttons and Features Battery Information Settings and Modes Sterilization and Cleaning Operating Your Breast Pump Breast Shield Sizing Assembling Your Collection Cups Turning The Motif Roam™ Pump On/Off...
  • Page 5 Using Your Motif Roam™ Pump Pumping Guide Getting Ready to Pump Aligning The Breast Shield Expressing Your Milk After Pumping Storing Breast Milk 10. Troubleshooting 10.1 Troubleshooting 10.2 Disposal 10.3 When to Replace Parts Technical Information 12. Warranty...
  • Page 7: Highlights

    Backflow protection keeps the perfect portability. motor clean, preventing contamination. Backlit LCD Screen Quiet Motor Easy-to-read screen that won’t A low hum that won’t wake strain your eyes. your baby. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 8: Intended Use (Indications For Use)

    3. Intended Use (Indications for Use) The Motif Roam™ Breast Pump is intended for use by lactating women to express and collect breast milk. The Motif Roam™ can be used as a single or double pump and is only intended for personal use.
  • Page 9: Symbols

    Serial number Manufacturer’s catalog number Refer to instruction manual IP21 Ingress protection Battery State Transport / Storage Humidity Operation Humidity Operation Temperature Storage Temperature Operating Pressure Transport / Storage Pressure MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 10 4. SYMBOLS Fragile Do not pile This way up Keep Dry Good Manufacturing Practice Logo Type BF applied part This product should not be mixed with other commercial waste for disposal Power Increases level of suction Decreases level of suction Mode Button...
  • Page 11: Safety

    Never operate this product if it has a damaged cord or plug, if it is not working properly, or if it has been dropped or damaged, or dropped into water. • Keep cord away from heated surfaces. • Never use while sleeping or when drowsy. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 12 If damage is found, immediately discontinue use of power adapter and call Motif Medical® Customer Service. • The Motif Medical® Twist should not be positioned so that it is difficult to operate the power adapter. Warning: To avoid health risk and reduce the risk of injury •...
  • Page 13 Breast pump parts may become damaged if mishandled, e.g. dropped, over- tightened or knocked over. • Take appropriate care in handling breast pump parts. • Do not use the breast milk if breast pump parts become damaged. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 14: Parts

    6. Parts 6.1 What’s Included While unpacking the box, make sure all of the following components are enclosed. Breast Pump Motor (1) 2 Tubing (2) 3 Tubing Connector (2) 4 Diaphragm (2) 5 Collection Cup (2) 6 Breast Shield (2) 7 Valve (4) 8 Power Adapter (1) Flange Inserts (16 mm, 19 mm, 21 mm, 24 mm)
  • Page 15 Full resupply kit with bottles and flanges • Flange inserts: 13 mm, 15 mm • Motif Roam bottles • Motif Roam nipples Find replacement parts and additional supplies for the Motif Roam at: motifmedical.com/replacement-supplies/ MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 16: Buttons And Features

    6. PARTS 6.2 Buttons and Features LCD SCREEN Massage Mode Time Display Expression Mode Power Display Cluster Feeding Mode Level General Display Pumping Mode Power Level Up Button Button Mode Button Level Down Button...
  • Page 17 Short press to switch between pumping modes. Level Up Button Short press to increase the vacuum (suction) level during any mode. Level Down Button Short press to decrease the vacuum (suction) level during any mode. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 18: Battery Information

    120 min Charge the battery as soon as there is 0-30% charge remaining. If the battery dies, your Motif Roam will automatically shut down. Do not use the pump when charging. It is recommended to charge your pump after each use when possible.
  • Page 19: Settings And Modes

    Suction Settings The suction level on your breast pump refers to the suction strength. When you are using your Motif Roam™, you will usually find that ex- pressing is most effective on the highest suction level that you are comfortable with.
  • Page 20 6. PARTS Specialized Modes The Motif Roam™ includes two custom modes, designed by a lactation professional, to maximize milk collection and minimize the time spent adjusting pump settings. Cluster Feeding Mode Mini power pumping mode that imitates a newborn’s cluster feeding to help boost milk supply.
  • Page 21: Sterilization And Cleaning

    Parts can also be sterilized in a steam sterilizer or microwave sterilization bag to sterilize collection cup parts quickly and efficiently. Be sure not to place tubing into the Sterilizer Bags in attempt to clean the tubing. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 22 7. STERILIZATION AND CLEANING Cleaning Instructions 1. Thoroughly wash your hands with soap and warm water. 2. Disassemble each collection cup part that came into contact with breast milk. This includes valves, diaphragms, breast shields, collection cups, and flange inserts. *Do not clean the tubing.
  • Page 23 *Never use water to wash the outside of your breast pump. 7. Store parts after they completely dry in a clean bag or container. *Do not store any damp parts. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 24: Operating Your Breast Pump

    8. Operating Your Breast Pump 8.1 Breast Shield Sizing Understanding size Pumping should not hurt. This guide is a starting point to help determine your optimal breast shield size based on your nipple diameter. How To Find The Right Size Breast Shield For You Step 1 Using a ruler, measuring AREOLA...
  • Page 25 25-28 mm Too Small Too Large Painful rubbing. Aerola is being pulled into the Try a larger size. flange tunnel. Only the nipple should enter the flange tunnel. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 26 8. OPERATING YOUR BREAST PUMP Finding Your Flange Size The breast shield for the collection cups is 28 mm. Box also includes 16 mm/19 mm/21 mm/ 24 mm flange inserts. If 16mm needed, push the insert of the 19mm correct size into the breast 21mm shield for a smaller fit.
  • Page 27: Assembling Your Collection Cups

    When single pumping, block the other port. Single Pumping Double Pumping MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 28: Turning The Motif Roam Pump On/Off

    8. OPERATING YOUR BREAST PUMP 8.3 Turning The Motif Roam Pump On/Off Press the POWER button Long press the power button to turn the pump on. The screen will light up and the pump will begin in Massage Mode in level 1.
  • Page 29 6. Ensure the tubing is tightly connected to prevent air leakage. 7. Place the collection cups on your breast underneath your bra. Adjust the length of the bra straps to make suction more comfortable. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 30 9. USING YOUR MOTIF ROAM™ PUMP 9.3 Aligning The Breast Shield Center the breast shield on your breast so that the nipple is drawn into the breast shield tunnel. It’s important that the breast shield is positioned properly before pumping begins to avoid any pain that may be caused by rubbing or twisting of your nipple onto the side of the breast shield.
  • Page 31: Expressing Your Milk

    1. 2. Press the Mode button to switch modes. There are four modes: Massage , Expression , Cluster Feeding , and General Pumping MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 32 9. USING YOUR MOTIF ROAM™ PUMP 3. Adjust the suction strength by pressing the LEVEL UP LEVEL DOWN button to find a comfortable setting. Massage and Cluster Feeding modes have 5 levels, while Expression and General Pumping modes have 9 levels.
  • Page 33 Never attempt to clean or sterilize pump parts when still assembled to ensure you are cleaning and sterilizing each part individually. Do not store milk in the collection cup. Do not wrap tubing around the breast pump to store. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 34: Storing Breast Milk

    9. USING YOUR MOTIF ROAM™ PUMP 9.6 Storing Breast Milk When storing breast milk in a milk storage bag, make sure to only use non-toxic markers when writing on the bag. Storage Locations / Temperatures Room Freezer Refrigerator Temperature 0°F (-18°C) 40°F (4°C)
  • Page 35 7. After thawing, milk should be stored in the refrigerator for no more than 24 hours. 8. Never refreeze thawed milk. Throw away previously frozen milk that is not used within 24 hours. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 36: Troubleshooting

    10. Troubleshooting 10.1 Troubleshooting Below you will find general conditions that may occur with your Motif Roam™ and corresponding troubleshooting solutions. Possible Condition Causes Checks Solutions Plug into the outlet. If it Check if the has damage, contact Motif Power power cord is not...
  • Page 37 Motif Medical® Customer Service Department. You can access them online at motifmedical.com via chat, through email at hello@ motifmedical.com or by phone (844) 272-8390. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 38 10. TROUBLESHOOTING 10.2 Disposal Please send components that are no longer used to Motif Medical® or properly dispose of the device in accordance with local, state, and federal regulations. As electrical and electronic equipment, the device must be disposed of according to a specialized procedure for...
  • Page 39 The silicone valves need to be replaced between 1 to 3 months based on how frequently they’re used because they can affect suction power. • It’s important to remember that smaller breast pump parts may not show any visible damage. MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 40 10. TROUBLESHOOTING Replacing your Diaphragms The diaphragms may stretch and lose elasticity over time, making them less effective at keeping moisture out of your breast pump motor. • They need to be replaced between 3 to 6 months depending on use.
  • Page 41: Technical Information

    85 to 106 kPa Temperature Humidity Pressure Transport and Storage Conditions Ambient temperature -4 to 131°F Relative humidity 20 to 80% Air pressure 90 to 106 kPa Temperature Humidity Pressure MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 42: Warranty

    12. Warranty Be sure to register your pump upon receiving it at: motifmedical.com/product-registration All Motif Medical® products purchased from authorized retailers come with a manufacturer’s warranty stating that product will be free from defects in workmanship and materials; for 2-years on double-electric breast pumps, for 1-year on internal batteries, and for 90-days on breast pump parts and the Manual Breast Pump.
  • Page 43 Manufactured for: Phone: (844) 272-8390 Motif Medical®, LLC Email: info@motifmedical.com 8 The Green, Suite 5601 Web: www.motifmedical.com Dover, DE 19901 MOTIF MEDICAL® | THE MOTIF ROAM™ BREAST PUMP | OPERATION MANUAL...
  • Page 44 Thank you for choosing the Motif Roam Breast Pump ™ (844) 272-8390 Motif Medical® info@MotifMedical.com 8 The Green, Suite 5601 www.motifmedical.com Dover, DE 19901...