TABLE OF CONTENTS SAFETY INFORMATION ................3 WEEE ............................... 3 EMC Information ............................4 PRECAUTIONS ..................8 Cautions When Setting Up ........................8 Cautions When Using ..........................10 Cleaning and Maintenance ........................10 Notice for the LCD Monitor ........................11 Notice for the LCD Display ........................
SAFETY INFORMATION WEEE Disposal of Waste Equipment by Users in Private Household in the European Union. This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
Do not put any portable and mobile RF communications equipment close to the DR-2202. Doing so may affect the DR-2202. The DR-2202 should not be used adjacent to or stacked with other equipment. If adjacent or stacked use is necessary the equipment or system should be observed to verify normal operation in the configuration in which it will be used.
Page 5
Guidance and manufacturer’s declaration – electromagnetic immunity The DR-2202 is intended for use in the electromagnetic environment specified below. The customer or the user of The DR-2202 should assure that it is used in such an environment. Not Life-supporting Medical Equipment.
Page 6
Guidance and manufacturer’s declaration – electromagnetic immunity The DR-2202 is intended for use in the electromagnetic environment specified below. The customer or the user of the DR-2202 should assure that it is used in such an environment. Not Lifesupporting Medical Equip- ment.
Page 7
The DR-2202 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the DR-2202 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the DR-2202 as recommended below, according to the maximum output power of the communications equipment.
SAFETY INFORMATION RECAUTIONS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN Symbols used in this manual This icon indicates the existence ISO 7010-M002: Follow instructions for of a potential hazard that could result in personal injury or damage to the product. This icon indicates important This icon indicates complies with the operating and servicing...
SAFETY INFORMATION RECAUTIONS Cautions When Setting Up Do not place the LCD monitor near heat sources, such as a heater, exhaust vent, or in direct sunlight. Do not cover or block the ventilation holes in the housing. Place the LCD monitor on a stable area. Do not place the LCD monitor where it may subject to vibration or shock.
Do not rub or tap the surface of the glass with sharp or abrasive items such as a pen or screwdriver. This AG Neovo for consultations and may result in scratching the surface of the glass. solutions to help ensure a most...
This is acceptable and is not considered a failure. The intended use of the DR-2202 is to serve as a LCD monitor for integration with the hospital system. It is designed for general purpose for adults using at hospital environment continuous operation.
Page 12
SAFETY INFORMATION RECAUTIONS Notice for the LCD Display Use a power cord that matches the voltage of the power outlet, which has been approved and complies with the safety standard of your particular country. The single device output analog signals through ADC element (Analog Digital Convert) conversion to become a digital signal and the video signal is via Video Decorder conversion.
CHAPTER 1: PRODUCT DESCRIPTION 1.1 Package Contents When unpacking, check if the following items are included in the package. If any of them is missing or damaged, contact your dealer. LCD monitor Note: Quick Start Guide Power adapter Must use only the supplied power adapter: ♦...
Users who have already mounted the display on the ceiling or any other horizontal surface overhead are strongly advised to contact AG Neovo for consultations and solutions to help ensure a most pleasurable and fulfilling display experience. Note:...
PRODUCT DESCRIPTION DICOM ENTER Hot Key: Input Source Selection • Press to toggle the DICOM function on or off. This function is used for reliably • Press to display the Input Source menu. uniform grayscale and brightness, crucial for 1 9 2 0 x 1 0 8 0 6 0 H z accurate medical assessments.
PRODUCT DESCRIPTION 1.3.3 Input/Output Terminals DICOM MENU ENTER DC IN DisplayPort HDMI AUDIO IN DC IN USB (SERVICE) Connect with the supplied power adaptor. Connect USB 2.0 for service. DisplayPort Connect VGA signals input. Connect DisplayPort signals input. AUDIO IN HDMI Connect audio signals input (3.5 mm Stereo Connect HDMI signals input.
PRODUCT DESCRIPTION 1.4 Cable Cover Removal To remove the cable cover, do the following steps: Place the LCD monitor with the screen side down on a cushioned surface. Then remove the screw securing the cable cover. Push the latches to disengage the cable cover from its compartment on the rear of the LCD monitor. Remove the cable cover.
PRODUCT DESCRIPTION 1.5 Making Connections Before connecting any cables, remove the cable cover to access the I/O terminals on the rear of the LCD monitor. See page 18. DICOM MENU ENTER DC IN DisplayPort HDMI AUDIO IN...
CHAPTER 2: ON SCREEN DISPLAY MENU 2.1 Using the OSD Menu Menu Navigation Operation Press the MENU button. Display the main menu screen. 1 9 2 0 x 1 0 8 0 6 0 H z P I C T U R E P I C T U R E M O D E DICOM S TA N D A R D...
Page 21
ON SCREEN DISPLAY MENU Menu Navigation Operation Adjust the settings. 1 Press the button to select an The highlighted item indicates the active submenu. option. For example: 2 Press the ENTER button to confirm. 1 9 2 0 x 1 0 8 0 6 0 H z 3 Press the button to select an...
CHAPTER 3: ADJUSTING THE SETTINGS 3.1 Picture Menu 1 9 2 0 x 1 0 8 0 6 0 H z P I C T U R E P I C T U R E M O D E DICOM S TA N D A R D D I C O M A U D I O...
Page 24
ADJUSTING THE SETTINGS Item Function Range If the COLOUR TEMP. setting is set to USER, you can customize the colour temperature by adjusting the red (R), green (G), or blue (B) setting according to your preference. 1 9 2 0 x 1 0 8 0 6 0 H z P I C T U R E P I C T U R E M O D E...
ADJUSTING THE SETTINGS 3.3 VGA Menu Note: ♦ This menu item is only available for VGA source. 1 9 2 0 x 1 0 8 0 6 0 H z P I C T U R E A U T O A D J U S T DICOM P R E S S A U D I O...
ADJUSTING THE SETTINGS Item Function Range RESET Reset all settings to the factory preset values. Press ENTER DEFAULT DICOM Different DICOM curves are provided for different ambient light 0,1,2,3,4,5 COMPENSATE variations 3.5 Information Menu 1 9 2 0 x 1 0 8 0 6 0 H z P I C T U R E I N P U T :...
CHAPTER 4: APPENDIX 4.1 Warning Message Warning Messages Cause Solution No signal from the current source The signal cable is not properly • Check the current signal source connected. output. • Switch to another signal source. S I G N A L •...
APPENDIX 4.3 Cleaning Caution When Using the Monitor • Do not bring your hands, face or objects close to the ventilation holes of the monitor. The top of the monitor is usually very hot due to the high temperature of exhaust air being released through the ventilation holes. Burns or personal injuries may occur if any body parts are brought too close.
APPENDIX 4.4 Troubleshooting Follow the solutions below to solve these common problems, and contact us if the problem persists. Symptom Possible Cause and Solution The Power LED indicator is • Check if the LCD monitor is turned ON. OFF. • Check if the power cord is properly connected to the LCD monitor. •...
Need help?
Do you have a question about the DR-2202 and is the answer not in the manual?
Questions and answers