Documents must be stored carefully and be available at all times. Contents may be periodically updated or revised due to product development. The information in this manual is subject to change without notice.The latest manual can be acquired via service@deye.com.cn Photovoltaic Grid-connected System...
�. Introduction �.� Appearance Introduction On-grid Inverter can convert solar panel DC power into AC power which can directly input to the grid. Its appearance is shown below.These models contain SUN-�K-G��P�-EU-BM�, SUN-�K-G��P�-EU-BM�, SUN-�K-G��P�-EU-BM�, SUN-�K-G��P�-EU-BM�, SUN-�K-G��P�-EU-BM�, SUN-�K-G��P�-EU-BM�, SUN-�K-G��P�-EU-BM�, SUN-��K-G��P�-EU-BM�, SUN-��K-G��P�-EU-BM�. The following is collectively referred to as “inverter”. Pic �.�...
�.� Parts list Please check the following table, to see whether all the parts are included in the package: Mounting stainless steel screws M��� Grid-tied PV String Inverter Wall mounting bracket x� x� x� DC+/DC- Plug connectors Stainless steel anti-collision DRM-Konnektor including metal terminal bolt M���...
�.� Product handling requirements Lift the inverter out of the packing box and transport it to designated installation location. transport CAUTION: Improper handling may cause personal injury! · Arrange an appropriate number of personnel to carry the inverter according to its weight, and installation personnel should wear protective equipment such as anti-impact shoes and gloves.
�.� Safety instructions Warning: Electrical installation of the inverter must conform to the safety operation rules of the country or local area. Warning: Inverter adopts non-isolated topology structure, hence must insure DC input and AC output are electrical isolated before operating the inverter. Shock Hazard: Prohibit disassembling inverter case, there existing shock hazard, which may cause serious injury or death, please ask qualified person to repair.
�. Operation Interface �.� Interface View Normal Alarm Pic �.� Front panel display �.� Status Indicator There are four LED status indicator lights in the front panel of the inverter. Please see table �.� for details. Indicator status Explanation Inverter detects DC input off...
�.� LCD Display The two-line Liquid Crystal Display (LCD) is located on the front panel of the Inverter, which shows the following information: Inverter operation status and data; ● Service messages for operator; ● Alarm messages and fault indications. ● �.
Page 11
Install on a wall or strong structure capable of bearing the weight. ● Install vertically with a maximum incline of +��°. If the mounted inverter is tilted to an angle ● greater than the maximum noted, heat dissipation can be inhibited, and may result in less than expected output power.
≥���mm ≥���mm Pic �.� Installation Gap �.� Installations Tools Installation tools can refer to the following recommended ones. Also, use other auxiliary tools on site. table �-� Tool specification Protective goggles Anti-dust mask Earplugs Work gloves Work shoes Utlity Knife Slotted screwdriver Cross screwdriver Percussion drill...
�.� Inverter Installation The inverter is designed according to the wall mounted type installation, please use the wall mounted (the brick wall of the expansion bolt) when installing. Anchoring Mounting bracket Stainless steel screws Inverter Pic �.� Inverter Installation Procedure shows below: �.
�. Ensure that the position of the installation holes on the wall is in accordance with the mounting plate, and the mounting rack is vertically placed. �. Hang the inverter to the top of the mounting rack and then use the M� screw in the accessory to lock inverter heat sink to the hanging plate, to ensure that the inverter will not move.
�.� DC input terminal connection �. Switch the Grid Supply Main Switch(AC)OFF. �. Switch the DC lsolator OFF. �. Assemble PV input connector to the inverter. Warning: When using PV modules, please ensure the PV+ & PV- of solar panel is not connected to the system ground bar.
Page 16
Please use its own DC power connector from the inverter accessories. Do not interconnect the connectors of different manufacturers. Max. DC input current should be ��A. if exceeds, it may damage the inverter and it is not covered by Deye warranty. - �� -...
�.� AC input terminal connection Do not close the DC switch after the DC terminal is connected.Connect the AC terminal to the AC side of the inverter, the AC side is equipped with Three phase AC terminals that can be conveniently connected.
�. Before making Grid port connection, be sure to turn off AC baeaker or disconnector first. �. Remove insulation sleeve ��mm length, unscrew the bolts, insert the wires according to polarities indicated on the terminal block and tighten the terminal screws. Make sure the connection is complete.
Warning: Inverter has built-in leakage current detection circuit, The type A RCD can be connected to the inverter for protection according to the local laws and regulations. If an external leakage current protection device is connected, its operating current must be equal to ��� mA or higher, otherwise inverter may not work properly. �.�...
�.� Inverter monitoring connection Inverter has the function of wireless remote monitoring. The inverter with Wi-Fi function is equipped with Wi-Fi Plug to connect the inverter and network. Wi-Fi Plug's operation, installa- tion, Internet access, APP downloading and other processes are detailed in the instructions. Phone GPRS Router...
�.� Configuration of datalogger For the configuration of datalogger, please refer to illustrations of the datalogger. �. Startup and Shutdown Before starting the inverter, make sure that the inverter can meet the following conditions, otherwise it may result in fire or damage to the inverter. In this case, we do not undertake any responsibility.
Page 22
Warning: The PID functionality is automatic.When the DC bus voltage is below ��VDC, the PID module will create ���VDC between the PV and ground.No control and equipment are required. Warning: If you need to maintain the inverter, Please turn off the AC switch first,then turn off the DC switch, and wait �...
Page 23
More usable models of DTSU��� series , please refer to Pic �.�-�.��. Suggest purchasing smart meters from authorized distributors of Deye or directly from Deye. When you are reading this, we believe that you have completed the connection according to the requirements of chapter �, if you have been running your inverter at this time, and you...
Page 24
� � � � � � � � L� L� L� Eastron L� L� L� Gird Load (�,�,�,�) (�,�,�,�) B A G RS ��� RS ��� B RS ��� A Eastron SDM���-Modbus V� Inverter Solar Panel array DRM/RCR AC Breaker RS ���...
Page 25
� � � � � � � � L� L� L� Eastron L� L� L� Gird Load (�,�,�,�) (�,�,�,�) B A G RS ��� RS ��� B RS ��� A Eastron SDM���-Modbus V� Inverter Solar Panel array DRM/RCR AC Breaker RS ���...
Page 32
�.� Multiple strings and parallel connection meters This application is that when the string inverters work in parallel, there is only one power grid and one load, and only one meter can be connected to prevent reverse current, so only this many-to-one anti-reverse current connection can be connected.
Page 33
Name Description Range AVG: Average power of three phase is zero exported. MIN: Phase with minimum load power is zero Exp_Mode AVG/MIN exported, while the other two phase may be in purchase mode. CT ratio of power grid side meter when extern CT is CT_Ratio �-����...
Page 34
� � � � � � � � L� L� L� Eastron L� L� L� Gird Load (�,�,�,�) (�,�,�,�) B A G RS ��� RS ��� B RS ��� A Eastron SDM���-Modbus V� Grid L� L� L� N Master Inverter(Mst) RS���...
Page 35
� � � � � � � � L� L� L� Eastron L� L� L� Gird Load (�,�,�,�) (�,�,�,�) B A G RS ��� RS ��� B RS ��� A Eastron SDM���-Modbus V� Generator L� L� L� N Master Inverter(Mst) RS���...
�.� Use of zero-export function When the connection is completed, the following steps should be refered to use this function: �. Turn on the AC switch. �. Turn on the DC switch, waiting for the inverter's LCD is turned on. �.
Page 43
�.� Notes while using zero export function For your safety and the operation of limiter function of the inverter, we put forward the follow- ing suggestions and precautions: Safety Hint: Under zero export mode we strongly recommend that the two PV arrays are formed by the same number of PV panels of the same size, which will make the inverter more responsive to limit the power.
Page 44
And then choose your system type as “Self-consumption” Edit Plant Cancel Done Address : Basic Info YongJiang Road, Beilum,NingBo, 315806, China System Info Yield Info Coordinates : Owner Info Longitude 19.03 Latitude 36.11 ” ” Time Zone : Creation Time : 2020/04/08 (UTC+08:00) Beijing,Chongqing,Hong Kong,Urumqi System Info...
8. General Operation During normal operation, the LCD shows the current status of the inverter, including the current power, total generation, a bar chart of power operation and inverter ID,etc. Press the Up key and the Down key to see the current DC voltage, DC current, AC voltage, AC current,inverter radiator temperature,software version number and Wifi...
Page 46
ActiveP Q-Mode VRated Q(%) ReactP Exp_Mode Fun- ISO CT_Ratio 0 Fun RCD FeedIn SelfCheck Shunt ShuntQTY Island Generator Meter G.CT Setup G.MFR Limiter G.FeedIn Running param G.Pout Feed-in V1-V12 G.Cap DC1-Wind OFF/ON MPPT Num DC2-Wind OFF/ON WindTurbine Cancel OF-Derate UF-Uprate WGRa WGraStr LVRT...
Page 47
*Note: These parameters will be avaiable after the meter is Brazil connected successfully. Otherwise, it won't show. EN50549-1-PL EN50549-1 Attention: For running param detail on the LCD display, please IEC61727 refer to the official Deye website https://www.deyeinverter.com CUSTOM VDE_4105 VDE_0126 Spain CEI_0-21 G98_G99...
Page 48
�.� The initial interface From the initial interface, you can check PV power, PV voltage, grid voltage, inverter ID, model and other infomation. Power: Power: State: Standby State: Com.Error Pic �.� The initial interface Press UP or Down, you can check inverter DC voltage, DC current, AC voltage, AC current and inverter temperature.
Page 49
ImpEp: Daily energy purchased from grid; Total: Total energy purchased from grid. ImpEp: 0.00KWh Total : 0.00KWh Pic �.�� Electrical energy ExpEp: Daily energy sold to grid; Total: Total energy sold to grid. ExpEp: 0.00KWh Total : 0.00KWh Pic �.�� Electrical energy �.�...
Page 50
�.�.� ON/OFF setting ON / OFF << Turn ON << Setup Turn OFF Turn ON Turn OFF << Cancel << Cancel Pic �.�� ON/OFF setting When the inverter is turned off, it stops working immediately, and go to standby mode and then will go to self-test program again.
�.� System param setting System Param includes time set, language set, display set and factory reset. Time Set << Display Set Language Set Factory Reset << Factory Reset Set Restore << Pic �.�� System Param 20200522 OK English << Polski 08:11:21 Cancel Pic �.��...
Page 52
�.� Protect Param setting Warning: Engineer Only. We will set the param depends on the safety requirements, so customers don't need to reset it. The password is same as �.� Running param PassWord GridStanderd << Advanced Back << Pic �.�� Password Braszil EN50549-1 EN50549-1-PL <<...
Page 53
OverVolt OverVolt Point 240.0V << Delay 1000ms << OverVolt OverVolt Point 240.0V << Delay 1000ms << OverVolt OverVolt Point 240.0V << Delay 1000ms << UnderVolt UnderVolt Point 235.0V << Delay 1000ms << UnderVolt UnderVolt Point 235.0V << Delay 1000ms << UnderVolt UnderVolt Point...
Page 55
�.� Three phase unbalance function setting ON / OFF System Param Setup << Param << PassWord Island Meter ON << Exp_Mode PHA<- CT_Ratio Pic �.�� 9. Repair and Maintenance String type inverter doesn’t need regular maintenance. However,debris or dust will affect heat sink’s thermal performance.
Page 56
Check the solar panel output connection. Failure in reading memory (EEPROM). Restart the inverter if the Read the memory error fault still exists, contact your installer or Deye service. Failure in writing memory (EEPROM). Restart the inverter if the Write the memory error fault still exists, contact your installer or Deye service.
Page 57
3. Check if the inverter FW version is suitable for the hardware. 4. Restart the inverter, if the error still exists, please contact your installer or Deye service. DC leakage flow fault Hardly appear the code. Never ever happened so far.
Page 58
1. Check AC current sensor and its circuit. AC over current(one cycle) 2. Restart the inverter, if the fault still exists, contact your installer or Deye service. DC over current Hardly appear the code. Never ever happened so far. Check the AC voltage protection setting. And Check if the AC AC Line W,U over voltage cable is too thin.Check the voltage difference between LCD and...
Page 59
DC busbar voltage is too low then showing F56, maybe Loss of driver or need update firmware. 3. Restart the inverter, if the fault still exists, contact your installer or Deye service. AC reverse irrigation AC reverse irrigation. AC grid U over current Hardly appear the code.
��.Specification SUN-�K-G��P� SUN-�K-G��P� SUN-�K-G��P� SUN-�K-G��P� Model -EU-BM� -EU-BM� -EU-BM� -EU-BM� PV String Input Data Max. PV Input Power(kW) �.� � �.� � Max. PV Input Voltage(V) ���� Start-up Voltage(V) ��� PV Input Voltage Range(V) ���-���� MPPT Voltage Range(V) ���-���� Full Load MPPT Voltage Range(V) ���-���...
Page 61
Interface Communication Interface RS���/RS��� Monitor Mode GPRS/WIFI/Bluetooth/�G/LAN(optional) Display LCD+LED General Data Operating Temperature Range (°C) -�� to +��℃,>��℃ derating Permissible Ambient Humidity �-���% Permissible Altitude (m) ����m Noise (dB) <�� dB Ingress Protection(IP) Rating IP �� Inverter Topology Non-Isolated Over Voltage Category OVC II(DC),OVC III(AC) ���×���×���...
Page 63
· Low Voltage Directive ����/��/EU (LVD) · Restriction of the use of certain hazardous substances ����/��/EU(RoHS) NINGBO DEYE INVERTER TECHNOLOGY CO., LTD. confirms herewith that the products described in this document are in compliance with the fundamental requirements and other relevant provisions of the above mentioned directives.
Need help?