d&b audiotechnik D80 Manual
Hide thumbs Also See for D80:
Table of Contents

Advertisement

Quick Links

D
D80
Manual 1.14 en

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D80 and is the answer not in the manual?

Questions and answers

Summary of Contents for d&b audiotechnik D80

  • Page 1 Manual 1.14 en...
  • Page 2: General Information

    General information D80 Manual Version: 1.14 en, 09/2019, D2020.EN .01 Copyright © 2019 by d&b audiotechnik GmbH & Co. KG; all rights reserved. Keep this document with the product or in a safe place so that it is available for future reference.
  • Page 3: Important Safety Instructions

    9. Unplug this apparatus during lightning storms or when unused for long periods of time. d&b D80 Manual 1.14 en...
  • Page 4: Table Of Contents

    11.4 Remote..................44 11.4.1 IP settings................44 11.4.2 Remote ID................45 11.5 More..................46 11.5.1 Preferences................46 11.5.1.1 Display................46 11.5.1.2 Lock.................. 47 11.5.1.3 Preferences/More............49 11.5.1.3.1 System reset..............49 11.5.2 Info..................50 11.5.3 Levels................... 51 d&b D80 Manual 1.14 en...
  • Page 5: Scope Of Supply

    3-pin South Africa 3-pin Argentina 3-pin Brazil 3-pin India GB 2099 SEV1011/T23 SANS 164-1 IRAM 2073 NBR 14136 IS 1293 *Mains plug types and associated standards (Graphics are similar illustrations only and not in scale) d&b D80 Manual 1.14 en...
  • Page 6: Intended Use

    Intended use The d&b D80 amplifier is designed for mobile applications and intended to be used with all current d&b loudspeakers. A LINEAR setup is available allowing the D80 to be used as a linear power amplifier. NOTICE! The device complies with the electromagnetic compatibility...
  • Page 7: D80 Concept

    AES3 channels or four AES3 channels. Each input channel can be routed to any of the output channels A to D. XLR connectors 2 and 4 of the D80 can be used as either digital or analog inputs, connectors 1 and 3 are analog inputs.
  • Page 8 Both, Ethernet and dbCAN protocols are incorporated. The Ethernet protocol implemented in the d&b R1 Remote control software V2 and the D80 amplifier is a protocol developed by the OCA Alliance (Open Control Architecture Alliance), of which d&b is a founding member. For further details, please refer to the OCA website: www.oca-alliance.com.
  • Page 9: Technical Specifications

    TFT color touch screen, 3.5" / 320 x 240 Pixel high range 100 to 127 V, 50 – 60 Hz low range Mains fuse internal Power consumption (typical values) Standby Idle 180 W Max. power consumption (short term RMS) 7000 W d&b D80 Manual 1.14 en...
  • Page 10: Digital Signal Processing

    Pink noise or Sine wave 10 Hz – 20 kHz Dimensions and weight Height x width x depth 2 RU x 19" x 530.5 mm 2 RU x 19" x 20.9" Weight 19 kg / 42 lb D80 enclosure dimensions in mm [inch] d&b D80 Manual 1.14 en...
  • Page 11: Overview

    Rotary encoder SCROLL/EDIT. indicators" on page 18, following Refer to Þ Chapter 6.3 "Controls and Þ Chapter 6.3.1 "Mains power indicators" on page 18 and switch" on page 18. Þ Chapter 7 "User interface" on page 21. d&b D80 Manual 1.14 en...
  • Page 12: Startup

    6" is usually sufficient) to accommodate the cables and connectors at the rear of the amplifier. When mounting D80 amplifiers into a 19" rack, do not just rely on fixing and supporting the amplifiers by their front panels using appropriate rack mounting screws and U washers as shown in the graphic opposite.
  • Page 13: Connections

    A powerCON-HC mains connector socket [1] is fitted on the rear ® panel and an appropriate power cord [2] is supplied. d&b D80 Manual 1.14 en...
  • Page 14: Audio Input And Link Connectors

    110 ohms, transformer balanced Sampling 48 / 96 kHz / 2 Ch/n Synchronization Word-Sync: PLL-locked to source (slave mode) LINK digital (Output) 3-pin XLR male electronically balanced analog signal buffering (refresh) Power Fail Relay (Bypass) d&b D80 Manual 1.14 en...
  • Page 15: Output Connectors

    1+/— = Channel A pos. / neg. 2+/— = Channel B pos. / neg. 3+/— = Channel C pos. / neg. 4+/— = Channel D pos. / neg. d&b D80 Manual 1.14 en...
  • Page 16: Ethernet (Dual Ethernet Port)

    Yellow ▪ Is off when the speed is 10 Mbit. ▪ Illuminates permanently when the speed is 100 Mbit. Network topologies Star topology Daisy chain topology for a Combined topology maximum of three devices d&b D80 Manual 1.14 en...
  • Page 17: Can (Can-Bus)

    RJ 45 connectors (metal housing) must be used while the cable shielding must be connected to both sides. CAN network topologies Daisy chain topology Combined topology With R60 USB to CAN interface With R70 Ethernet to CAN interface d&b D80 Manual 1.14 en...
  • Page 18: Controls And Indicators

    Due to the wide range of functions the user interface is described separately in more detail in Þ Chapter 7 "User interface" on page 21. However, both the Standby and Mute functions of the D80 are described in the following two sections. d&b D80 Manual 1.14 en...
  • Page 19: Standby Mode

    Mute function instead of Standby. However, the Standby mode can be useful with mid/high systems as it removes any residual noise from the system. d&b D80 Manual 1.14 en...
  • Page 20: Mute Functions

    Startup 6.3.4 Mute functions The D80 provides two mute functions: ▪ Individual mute buttons for each channel or pair of channels, depending on the output mode configuration Þ Channel mute, ▪ and a master mute function Þ «Mute all». Note: The device stores the setting of the mute buttons when the mains power is switched off or disconnected.
  • Page 21: User Interface

    (counterclockwise) decreases it. To leave Edit mode press the encoder or simply tap the respective Menu item again. The color of the frame will change from yellow back to white again Þ Position cursor. d&b D80 Manual 1.14 en...
  • Page 22: Screen Layout And Conventions

    Device and Channel setup screens 7.3 Screen items and views This section describes the different menu items, views and function elements characterizing the user interface of the D80. 7.3.1 Function buttons Properties: ▪ The top left of the button shows the function name while the bottom right shows the status of the function.
  • Page 23: Input Fields

    (alphanumeric keypad) or an IP address (numeric keypad). ▪ Selection and editing is performed using the touch screen or turning and pushing the encoder. 7.3.5 Information fields Properties: Non-selectable/non-editable field for information purposes only. d&b D80 Manual 1.14 en...
  • Page 24: Home Screen

    In addition, the Home screen gives direct access to the Remote subscreen. The Home screen can be accessed from any screen or menu at any level using the Home button ( ). Home screen access chart Hierarchy level d&b D80 Manual 1.14 en...
  • Page 25: Header Area - Device

    All vital information is displayed. This includes: ▪ Input signal present (ISP) ▪ Input routing ▪ Channel configuration, ▪ Controller output signal (OSP) ▪ Channel mute buttons and status. ▪ Error messages d&b D80 Manual 1.14 en...
  • Page 26: Channel Strip

    Channel strip Channel strip D80 Channel strip block diagram (signal chain) The channel strip follows the actual signal chain from left to right: ISP/OVL Indicates the following states for both, the analog ( ) and the digital ( ) signal inputs: Grey The relevant channel is not available.
  • Page 27 Channel muted Channel unmuted A channel error is indicated on the Channel mute button by an exclamation mark Þ A corresponding error message is issued on the Channel view button. d&b D80 Manual 1.14 en...
  • Page 28: Basic Settings - Quick Reference

    Basic settings - Quick reference Basic settings - Quick reference Due to the vast functional range and possible settings of the D80 amplifier, this section is intended as a quick reference to provide you with a systematic procedure for defining the basic settings of the amplifier.
  • Page 29 Note: A detailed description of the Input mode is given in the reference chapter Þ Chapter 11.2 "Input" on page 32. A detailed description of the Input routing is given in the reference chapter Þ Chapter 12.6 "Input routing" on page 62. d&b D80 Manual 1.14 en...
  • Page 30: Device Setup

    Device setup Device setup Device setup access chart Hierarchy level d&b D80 Manual 1.14 en...
  • Page 31: Device Name

    Tapping «OK» on the top right confirms the entry, closes the input mask and switches back to the Device setup screen. Tapping the Back button ( ) on the top left cancels any entry and switches back to the Device setup screen keeping the previous entry. d&b D80 Manual 1.14 en...
  • Page 32: Input

    Þ Fallback Þ Override 11.2.1 Input mode Input mode block diagram Analog/Analog Both input connector pairs 1/2 and 3/4 are set to «Analog», an analog audio signal is accepted by inputs 1, 2, 3 and 4. d&b D80 Manual 1.14 en...
  • Page 33 If D1/2 and D3/4 are used as Master/Slave, both clock signals (external/internal) are not synchronous. Syncing The DSPs are synchronizing (transitional state). Use SRC The external clock is either 44.1 kHz or 88.2 kHz (in connection with SRC). SRC is switched on. d&b D80 Manual 1.14 en...
  • Page 34: System Clocking

    The on/off status of each function is indicated by change in color of the respective button from grey to blue or vice versa. Below these buttons, there is a graphical presentation of the actual input routing. d&b D80 Manual 1.14 en...
  • Page 35: Input Monitoring

    Center frequency of the pilot band, adjustable from 5 Hz to 24 kHz in 1 Hz or 0.01 Hz increments. The chosen increment is shown in light grey at the top right of the field. d&b D80 Manual 1.14 en...
  • Page 36: Input Gain

    The on/off status is indicated by a change in color of the button from grey to blue or vice versa. Clear All gain settings are reset to factory default (0 dB) while the function remains activated. d&b D80 Manual 1.14 en...
  • Page 37: Fallback

    After the Fallback function has been triggered, it can be reset manually by reactivating (selecting) the «Regular 1/2» input source. This can be done either locally or via the Web Remote interface or via the d&b Remote network using R1. d&b D80 Manual 1.14 en...
  • Page 38: Override

    When the function is activated, the input has the highest priority for general messages or emergency services. When Override is activated, the analog input A3 is disabled on INPUT the Input routing screen and «Override» is displayed (flashing D3/4 D1/2 when active). LINK d&b D80 Manual 1.14 en...
  • Page 39 Attack time, adjustable from 0.01 sec. to 1 sec. in 0.01 sec. increments. Hold Hold time, adjustable from 0 sec. to 10 sec. in 0.1 sec. increments. Release Release time, adjustable from 0 sec. to 10 sec. in 0.1 sec. increments. d&b D80 Manual 1.14 en...
  • Page 40: Output

    2 x Dual Channel 2 x Mix TOP/SUB 2 x 2-Way Active Mixed configuration On the bottom left of the Output screen, the «Speaker» navigation button provides direct access to the Þ Speaker setup screen. d&b D80 Manual 1.14 en...
  • Page 41: Output Mode

    11.3.1 Output mode NOTICE! Ensure that the connected loudspeaker type corresponds to the actual output configuration of the D80. Dual Channel mode (A/B, C/D) The Dual Channel mode is dedicated to d&b fullrange systems (passive systems) and actively driven d&b subwoofers. Both channels of each pair of amplifier channels can be configured for TOP or SUB cabinets independently.
  • Page 42 1 = Amp A (C) pos. (LF) 2 = Amp A (C) neg. (LF) 3 = Amp B (D) pos. (MF/HF) 4 = Amp B (D) neg. (MF/HF) 5 = n.c. 2 x 2-Way Active mode d&b D80 Manual 1.14 en...
  • Page 43 ▪ AMP A/B Þ Dual Channel, AMP C/D Þ Mix TOP/SUB ▪ AMP A/B Þ Mix TOP/SUB, AMP C/D Þ 2-Way Active ... as well as all other combinations are also possible. Mixed configuration example AMP A/B Þ Dual Channel, AMP C/D Þ 2-Way Active d&b D80 Manual 1.14 en...
  • Page 44: Remote

    The DHCP+LL setting enables the amplifier to also work in a setup without a DHCP server. A fully functional local network including remote control from a PC or Mac via R1 will be set up automatically. d&b D80 Manual 1.14 en...
  • Page 45: Remote Id

    Remote ID exceeds 7.63, CAN disabled! Device ID Using the two digit Device ID for each subnet, you can define a total of 63 devices (values 1 to 63). d&b D80 Manual 1.14 en...
  • Page 46: More

    An indication is that when you tap a specific button and the adjacent button is activated instead or when a specific button does no longer work. In such cases, the touch screen should be recalibrated. d&b D80 Manual 1.14 en...
  • Page 47: Lock

    Note: The factory default password is: dbaudio Lock Tapping the «Lock» button confirms any new settings and exits the subscreen. A corresponding message is displayed. The device will be switched to the screen selected for Lock mode. d&b D80 Manual 1.14 en...
  • Page 48: Unlocking The Device

    3. Release the encoder and briefly press the encoder again within 2 sec. ↳ Short confirmation beep. The device will boot up and will switch to the Home screen. A corresponding message will be issued: d&b D80 Manual 1.14 en...
  • Page 49: Preferences/More

    To prevent accidental reset when you tap the «Clear...» button, a dialog will pop up prompting you to confirm the reset or cancel the sequence by tapping the Back button ( ). d&b D80 Manual 1.14 en...
  • Page 50: Alternative Procedure

    In addition, there is dynamic information about the actual temperatures of... : ▪ Power supply (Temp. PS) ▪ The entire power amplifier (Temp. AMP) ▪ Central Processing Unit (Temp. CPU) Selecting the «Hardware» button provides further hardware specific information. d&b D80 Manual 1.14 en...
  • Page 51: Levels

    (OVL). Mains/SMPS Displays the actual mains voltage and frequency, the actual mains power consumption in combination with a power limiter LED and the actual temperature of the switched mode power supply (SMPS). d&b D80 Manual 1.14 en...
  • Page 52: Mains Current Limiter (Mcl)

    11.5.4 Mains current limiter (MCL) Selecting «Mains current limiter» opens the corresponding subscreen. The D80 features a power limiter which serves to limit the mains current draw whenever the mains current draw threatens to trigger the circuit breaker. Limiting is done by reducing the sound levels evenly on all channels.
  • Page 53: Amppresets

    AmpPresets screen. ▪ Selecting the Back button ( ) on the top left cancels any entry and switches back to the AmpPresets screen keeping the previous entry. d&b D80 Manual 1.14 en...
  • Page 54: Scope

    ▪ getting a rough impression of the crest factor. ▪ checking the output channels (e.g. no output current displayed Þ the connector cable may be interrupted or no loudspeaker is connected. ▪ checking the power amplifier (e.g. no output voltage displayed). d&b D80 Manual 1.14 en...
  • Page 55: Autostandby

    Inputs tab When the AutoWakeup function is enabled, the corresponding inputs that will be monitored for incoming signals can be specified. d&b D80 Manual 1.14 en...
  • Page 56: Channel Setup

    Channel setup Channel setup Channel setup access chart Hierarchy level d&b D80 Manual 1.14 en...
  • Page 57: Channel Name

    Tapping «OK» on the top right confirms the entry, closes the input mask and switches back to the channel setup screen. Tapping the Back button ( ) on the top left cancels any entry and switches back to the Channel setup screen keeping the previous entry. d&b D80 Manual 1.14 en...
  • Page 58: Configuration Switches - Filter_1

    12.3 Level Input sensitivity of the respective power amplifier channel or set of channels (depending on the output mode), adjustable within a range of —57.5 dB to +6 dB in steps of 0.5 dB. d&b D80 Manual 1.14 en...
  • Page 59: Eq - Equalizer

    Back button ( ). Copy/Paste Allows the entire EQ settings of one channel to be copied/pasted to any other channel. To do so, proceed as follows: d&b D80 Manual 1.14 en...
  • Page 60 Depending on the filter type used, 1 to 4 bands may be required for each filter. The following table lists the available types, their corresponding parameters and the number of filter bands required for the selected type. d&b D80 Manual 1.14 en...
  • Page 61 Slope can be set to 6, 12, 18 or 24 dB/octave. Gain Gain, adjustable from –18 dB to +12 dB in 0.2 dB steps. Clear Resets all settings of the selected filter band right away. band d&b D80 Manual 1.14 en...
  • Page 62: Dly - Delay

    The Input routing screen also provides direct access to the Þ «Input mode» screen. d&b D80 Manual 1.14 en...
  • Page 63 A simple example is shown in the graphic opposite. The stream labels are stated in inverted commas. The corresponding labels and their locations on the screen are listed in the table below. Out 1/2 Main R@FoH DS10 Stage R Front - Output 1 d&b D80 Manual 1.14 en...
  • Page 64: System Check/Lm

    To verify the correct connection of cabinets and amplifiers, the calibration result can be compared with the typical impedance values for d&b loudspeakers as listed in the Þ Appendix: " Typical impedance (Z) values" on page d&b D80 Manual 1.14 en...
  • Page 65: Load Monitoring (Lm)

    " Max. number of cabinets operated in parallel" on page 86. Load monitoring does not work if: ▪ the amplifier is switched off or switched to standby mode. ▪ the respective channel is muted. ▪ the pilot signal level is too low. d&b D80 Manual 1.14 en...
  • Page 66: Speaker

    Series. The list is in alphabetical order, the starting point, however, is the Series currently loaded. Selecting «(All)» provides direct access to all setups available and the LINEAR setup. d&b D80 Manual 1.14 en...
  • Page 67 LoadMatch subscreen which is described in Þ Chapter 12.8.2 "LoadMatch" on page 69. Note: LoadMatch does not apply to all loudspeakers. When the function is not applicable, this button is not functional. d&b D80 Manual 1.14 en...
  • Page 68: Arrayprocessing

    On the Home screen, the On/Off status and the setting of the HF Trim option is indicated by the entry «HFT[n]» on the «Channel view» button of the corresponding channel strip, as shown in the graphic opposite. d&b D80 Manual 1.14 en...
  • Page 69: Loadmatch

    Þ The resulting cable impedance is shown as an ohmic value in the «Cable impedance» information field underneath. Maximum gain reached Depending on the LoadMatch settings, the message «Maximum gain reached» indicates the limit up to which the LoadMatch function works. d&b D80 Manual 1.14 en...
  • Page 70: Linear Setup

    Channel setup 12.8.3 LINEAR setup In addition to the loudspeaker specific setups, a LINEAR setup is also available allowing the D80 to be used as a linear power amplifier. Note: CUT in LINEAR setup: ▪ Butterworth 2nd order (12 dB/oct.) ▪...
  • Page 71: Frequency Generator - Freq. Gen

    EQ settings, if applicable. On the Home screen, the On/Off status of the generator is indicated by the entry «FG» on the Channel view button of the corresponding channel strip, as shown in the graphic opposite. d&b D80 Manual 1.14 en...
  • Page 72: Web Remote Interface

    The «Web Remote» tab shows the actual screen of the connected amplifier. All screens and screen items can be accessed by simply clicking the relevant item. Edit For applicable parameters, the «Edit» button becomes accessible and a corresponding dialog will pop up. d&b D80 Manual 1.14 en...
  • Page 73 This is very useful when entering major changes. The counter field will also appear and behaves in the same manner as described above. 4. To confirm the set value, click the relevant field again or click the respective «OK» button. d&b D80 Manual 1.14 en...
  • Page 74: Keyboard Entries

    In addition, a storage option is provided which allows you to store the Event log data locally. This is mainly intended for service and/or troubleshooting purposes. To save the Event log data locally, proceed as follows: d&b D80 Manual 1.14 en...
  • Page 75 2. As a final step, select the «Activate backup file on device» button to apply the backup and remote settings. d&b D80 Manual 1.14 en...
  • Page 76: Licenses And Copyright

    Þ To exit the «Service» tab functions, click the «Logout» button at the top. Licenses and Copyright Selecting the d&b logo at the top left opens the «Licenses and Copyright» information page. d&b D80 Manual 1.14 en...
  • Page 77: Operation (Hardware References)

    100 - 127 V  A C Auxiliary Power Supply The Auxiliary Power Supply feeds the DSP section and the device control and operates within the range from 55 V  A C 400 V  A C d&b D80 Manual 1.14 en...
  • Page 78: Mains Inrush Current Limiter

    14.1.4 Mains inrush current limiter The Main Power Supply is started softly to limit inrush current. Up to two D80 may be powered up at the same time without triggering a line circuit breaker of 13-16 A (230 V) or 30 A (100-120 V) respectively.
  • Page 79: Generator Operation/Ups Requirements

    To operate the amplifier using a mains generator or uninterruptible power supply (UPS), observe the following: ▪ With the D80 amplifier the apparent power figure (VA value) is about the same as the effective power figure (W value). ▪ Use a generator or UPS that can deliver the maximum power required by the entire system.
  • Page 80: Power Amplifiers

    Operation (Hardware references) 14.2 Power amplifiers The power amplifiers fitted to the D80 utilize Class D technology similar to a switch mode power supply. Compared to the known linear amplifier concept (Class A, AB, G or H), Class D power amplifiers produce less heat and allow for a compact and light- weight design.
  • Page 81 Signal CF 12 dB cont. 4 Ω/Ch. 29.00 0.99 2900 2000 3071 Signal CF 9 dB cont. 4 Ω/Ch. 32.50 0.99 3250 2150 1100 3753 Signal CF 9 dB max. 4 Ω/Ch. 55.00 0.99 5500 3500 2000 – – d&b D80 Manual 1.14 en...
  • Page 82: Service/Maintenance And Care

    TFT screens. In this case proceed as follows: 1. Spray on the soft cloth before wiping the screen. ↳ Never apply/spray directly on the screen as the liquid could penetrate the device. 2. Wipe the screen with moderate pressure. d&b D80 Manual 1.14 en...
  • Page 83: Touch Screen Calibration

    1. From the «Home screen» go to «Device setup» Þ «More» Þ «Preferences» Þ «Display». 2. Select «Touch screen calibration». ↳ The calibration menu will be opened guiding you through the calibration procedure. 3. Follow the on screen instructions respectively. d&b D80 Manual 1.14 en...
  • Page 84: Manufacturer's Declarations

    D80 Amplifier, Z2710 manufactured by d&b audiotechnik GmbH & Co. KG. All products of type D80 starting from variant Z2710.000 are included, provided they correspond to the original technical version and have not been subject to any later design or electromechanical modifications.
  • Page 85: Appendix

    A DC resistance measurement using a multimeter may produce different results. D80 amplifiers apply audible low level signals in the low frequency range for a few seconds using dedicated frequencies for each cabinet type. This reduces the impact of ambient temperature and mechanical aging of the driver components on the impedance values.
  • Page 86: Max. Number Of Cabinets Operated In Parallel

    System Failure mode Single cabinet HF section of Single HF/MF LF section of Single LF driver disconnected single cabinet driver single cabinet 24C-E 10AL/10AL-D 10S/10S-D/10A/10A-D 12S12S-D 24S/24S-D 12S-SUB 18A-SUB/18S-SUB 21S-SUB 27A-SUB/27S-SUB AL60/AL90 B1-SUB B2-SUB d&b D80 Manual 1.14 en...
  • Page 87 B22-SUB B4-SUB B6-SUB B8-SUB C4-TOP C4-SUB C6/C690 C7-TOP C7-SUB Ci-SUB Ci45/60/90 Ci80 E12/12-D E12-SUB E12X-SUB E15X-SUB F1222 GSL8/GSL12 J8/J12 J-SUB J-INFRA KSL8/KSL12 MAX2 MAX12 Q1/Q7/Q10 Q-SUB SL-SUB/SL-GSUB T-SUB V8/V12 V7P/V10P V-SUB/V-GSUB Y7P/Y10P Y8/Y12 Y-SUB d&b D80 Manual 1.14 en...
  • Page 88: Possible Error Messages

    Mains voltage is/was >276V >276V (avg %3dV, too high. peak %3dV, status %04X, err %04X) Mains undervoltage Mains undervoltage Mains undervoltage (External: Mains) Mains voltage is/was (avg %3dV, peak too low. %3dV, status %04X, err %04X) d&b D80 Manual 1.14 en...
  • Page 89 Invalid device para Channel '%c': invalid Invalid device Software error or device parameters parameters wrong device type (device ident %d) detected. Invalid DSP prog %u Channel '%c' : invalid DSP program invalid Software error. DSP program %d d&b D80 Manual 1.14 en...
  • Page 90 Filter ovrtemp %d Channel '%c': Amp. Amp over Poor cooling. °C filter over temperature temperature of output %d°C (power filters %uW) Amp. clock fault Channel '%c': Amp. Amp clock fault Amp defect. clock fault (%3dkHz, power %uW) d&b D80 Manual 1.14 en...
  • Page 91: Display Text

    Input monitoring fault A%d (%4.1ddBu, threshold %4.1ddBu) Input monitoring fault Input monitoring fault Input monitoring fault A%d (%4.1ddBu, threshold %4.1ddBu) Input monitoring fault Input monitoring fault Input monitoring fault D%d (lock %d, %4.1ddBFS, threshold %4.1ddBFS) d&b D80 Manual 1.14 en...
  • Page 92 Input monitoring fault D%d (lock %d, %4.1ddBFS, threshold %4.1ddBFS) Input monitoring fault Input monitoring fault Input monitoring fault D%d (lock %d, %4.1ddBFS, threshold %4.1ddBFS) Ethernet overload Ethernet overload, Ethernet overload Too much network throttling active traffic. d&b D80 Manual 1.14 en...
  • Page 93 www.dbaudio.com...

Table of Contents