Summary of Contents for Sigenergy Sigen Hybrid 5.0 TP
Page 1
Sigen Hybrid (5.0-30.0) TP AU SigenStor EC (5.0-30.0) TP AU User Manual Version: 03 Release date: 2025-03-25 1 / 27...
Page 2
Therefore, description in this document is provided for reference purpose only and constitutes neither an offer nor an acceptance. Sigenergy Technology Co., Ltd. may change the information at any time without notice.
Page 3
Contents Revision History ..........................4 Overview ............................. 5 Chapter 1 Safety Precautions ......................6 Chapter 2 Product Introduction ..................... 8 2.1 Product Model No........................8 2.2 Appearance Introduction ..................... 10 2.3 Label Description ........................12 2.4 Supported Power Supply Methods for the Power Grid ............
Page 4
User Manual Revision History Version Date Description Updated Chapter 6 System Maintenance 2025.03.25 Updated Chapter 7 Appendix (DVC) Updated Chapter 2 Product Introduction 2024.04.19 Updated Chapter 3 Site Selection Requirements 2024.01.30 First official release. 4 / 27...
Page 5
User Manual Overview Introduction The focus of this document is to provide an overview of the SigenStor EC (5.0-30.0) TP AU and Sigen Hybrid (5.0-30.0) TP AU inverter, including product features, networking, system operation, maintenance, etc. Readers This document is suitable for product users and professionals Sign Definition The following signs may be used in the document to indicate security precautions or key information.
Page 6
User Manual Chapter 1 Safety Precautions Basic Information Before installation, operation, and maintenance of the equipment, familiarize yourself with this document. The "Danger ", "Warning", "Caution" items described in this manual are only supplementary to all precautions. The Company shall not be liable for equipment damage or property loss caused by the following reasons: Failure to obtain approval from the national, regional power authority.
Page 7
User Manual equipment is too high or too low). The equipment was stolen. The equipment is damaged after the warranty period. Safety Requirements Do not expose the device to high temperature or heat sources (such as sunlight, fire, or heaters) around the equipment for a long time. Do not clean or soak the equipment with water, alcohol, or oil to avoid ...
Page 8
Product Function Model No. Name code specification Sigen Hybrid Inverter Sigen Hybrid 5.0 TP 5.0 kW Three Phase Sigen Hybrid Inverter Sigen Hybrid 6.0 TP 6.0 kW Three Phase Sigen Hybrid Inverter Inverter; it can be Sigen Hybrid 8.0 TP 8.0 kW Three Phase...
Page 9
User Manual Sigen Energy PV modules for SigenStor EC 6.0 TP Controller 6.0 kW pure PV Three Phase applications or in combination with Sigen Energy PV modules and SigenStor EC 8.0 TP Controller 8.0 kW SigenStor BAT for Three Phase photovoltaic storage systems Sigen Energy...
Page 10
User Manual 2.2 Appearance Introduction Appearance and Dimensions 10 / 27...
Page 11
User Manual Port Introduction Serial No. Name Marking Decorative cover strip light interface (This interface is unavailable for Sigen PV Max) Network interface RJ45 1/ RJ45 2 DC input interface PV1+/PV2+/ PV3+/PV4+/ PV1-/PV2- /PV3-/PV4- AC output interface Communication interface Ground screw Switch button ON/OFF (This button is unavailable for Sigen PV Max)
Page 12
User Manual 2.3 Label Description Symbols Definition Danger! High Voltage High voltage exists inside the equipment when powered on. Do not open the casing when the equipment is running. Any maintenance or servicing operations must be performed by trained and skilled electrical engineers. Warning! Life at risk.
Page 13
User Manual Supported Power Supply Methods for the Power Grid The grid supply methods supported by Sigen PV Max or Sigen Hybrid include TN-S, TN-C, TN-C-S , TT and IT. When TT is used as the power supply technique for the power grid, the ...
Page 14
User Manual Introduction to Typical Networking Sigen PV Max or Sigen Hybrid is designed for grid-connected photovoltaic systems on residential rooftops. The grid-connected system consists of photovoltaic strings, inverters, distribution panels, and other components. A. PV panel B. Sigen PV Max/Sigen Hybrid C.
Page 15
User Manual It is recommended to use FE and WLAN for communication with inverter. CommMod users must top up their own 4G data plan after a period of 2 years. 15 / 27...
Page 16
User Manual Chapter 3 Site Selection Requirements The warranty applies when the equipment has been installed properly for its intended use and in accordance with the operating instructions. During actual installation, the selection of installation location should comply with local firefighting, environmental protection regulations, and other relevant laws.
Page 17
User Manual Do not install the equipment in places with fire or damp. Please keep away from the daily work and living places. Do not install the equipment in a sealed, poorly ventilated location without fire protection measures and difficult access for firefighters. The equipment is hot when it is running.
Page 19
User Manual Chapter 4 Equipment Installation and Wiring Only company authorized personnel should install and connect the equipment. For details, see Sigen PV Max (5.0-30.0)TP, Sigen Hybrid (5.0-30.0)TP Installation Guide. Parts and accessories supplied with the packing box are personal assets of the owner and must be kept safe.
Page 20
User Manual Chapter 5 System Operation 5.1 LED Indicator State Indicator Color State Description Always on The DC side is connected but not running. Always on The DC side is running. The DC side is not connected. Flash The DC side is faulty. Always on The inverter is faulty.
Page 21
User Manual 5.2 mySigen App Query The App can be downloaded in the following two ways. For details, see mySigen App User Manual. 21 / 27...
Page 22
User Manual Chapter 6 System Maintenance 6.1 Routine Maintenance To ensure the long-term running of the equipment, you are advised to perform routine maintenance according to this section. Inspection Inspection method Power off Maintenance content or not cycle System Check the device regularly for Once every cleaning shielding and dirt.
Page 23
User Manual 6.2 Equipment Powering-on/Power-off Scheme 1: App operation Tap "Setting" in mySigen APP to turn on/off the device. Scheme 2: Manual operation Follow the steps shown to remove the side and top decorative cover, and press the ON/OFF switch button. Press and hold for more than 3s to turn on or off the power;...
Page 24
User Manual 3. Turn off the switch connected to the equipment in the backup power distribution panel. 4. After all LED indicators on the equipment go off, wait for the corresponding time as indicated on the label on the equipment before proceeding. In case of prolonged inactivity of the equipment (such as being offline for several consecutive days or having minimal operational hours), the system will issue a reminder.
Page 25
User Manual 6.3 Emergency Treatment Emergency Measures for Fire Please shut down the equipment or disconnect the main power switch when it is safe. If the fire is small, use carbon dioxide or ABC dry powder extinguisher to extinguish the fire.
Page 26
Environmental category:outdoor, indoor conditional, indoor unconditional; backfeed current: 0A; For Sigen Hybrid 5.0 TP AU, the inrush current is 7.2 A, the Max. output overcurrent protection is 7.2 A, the Max. output fault current is 17.8 A; For Sigen Hybrid 6.0 TP AU, the inrush current is 10.0 A, the Max. output overcurrent protection is 10.0 A, the Max.
Page 27
User Manual For Sigen Hybrid 20.0 TP AU, the inrush current is 33.4 A, the Max. output overcurrent protection is 33.4 A, the Max. output fault current is 70.9 A; For Sigen Hybrid 25.0 TP AU, the inrush current is 41.8 A, the Max. output overcurrent protection is 41.8 A, the Max.
Need help?
Do you have a question about the Sigen Hybrid 5.0 TP and is the answer not in the manual?
Questions and answers