Page 2
Therefore, description in this document is provided for reference purpose only and constitutes neither an offer nor an acceptance. Sigenergy Technology Co., Ltd. may change the information at any time without notice.
Contents 2.1 Product Model ........................9 2.2 Appearance Introduction ....................10 Appearance and Dimensions ..................10 Port Introduction ......................11 2.3 Label Description ........................ 13 2.4 Supported Power Supply Methods for the Power Grid ..........14 2.5 Typical Networking Introduction ..................15 5.1 Working Mode........................
Page 4
User Manual Revision History Version Date Description 2024.08.01 First official release. 4 / 38...
Page 5
User Manual Overview Introduction This document describes product introduction, networking, system operation and maintenance of SigenStor-5S-(5-16) and SigenStor-6S-(8-24) (hereinafter referred to as SigenStor). Readers This document is suitable for product users and professionals Sign Definition The following signs may be used in the document to indicate security precautions or key information.
Page 6
User Manual Safety Precautions Basic Information Before installing, operating, and maintaining the equipment, familiarize yourself with this document. The "Danger ", "Warning", "Caution" items described in this manual are only supplementary to all precautions. The Company shall not be liable for equipment damage or property loss caused by the following reasons: Failure to obtain approval from the national, regional power authority.
Page 7
User Manual Equipment damage caused by force majeure (such as war, earthquake, fire, storm, lightning, flood, debris flow, etc.). Damage caused by the failure of the natural environment or external power parameters to meet the standard requirements of the equipment during actual operation (for example, the actual operating temperature of the equipment is too high or too low).
Page 8
User Manual Do not use the equipment with faults. If the equipment appears abnormal (for example, battery pack leakage or appearance distortion), contact your sales agent. It is prohibited to disassemble the equipment by yourself. Carbon dioxide fire extinguishers or ABC dry powder fire extinguishers are ...
SigenStor contains single-phase inverters and battery packs and can store and release electric energy in response to the management system. Model Number of SigenStor Number of SigenStor Model Inverter model BATs 5.0 BATs 8.0 SigenStor-5S-5 SigenStor-5S-8 SigenStor EC 5.0 SP SigenStor-5S-10 SigenStor-5S-13 SigenStor-5S-16 SigenStor-6S-8 SigenStor-6S-10 SigenStor-6S-13 SigenStor EC 6.0 SP...
User Manual 2.2 Appearance Introduction Appearance and Dimensions The preceding figure takes two SigenStor BATs as an example to show the appearance. 10 / 38...
User Manual 2.3 Label Description Symbols Definition Danger! High Voltage High voltage exists inside the equipment when powered on. Do not open the casing when the equipment is running. Any maintenance or servicing operations must be performed by trained and skilled electrical engineers. Warning! Life at risk.
User Manual Supported Power Supply Methods for the Power Grid The grid supply methods supported include TN-S, TN-C, TN-C-S, and TT. When TT is used as the power supply technique for the power grid, the voltage between N and PE is required to be < 30 V. 14 / 38...
User Manual Typical Networking Introduction SigenStor can be used for Single-phase Home energy storage system. The Home energy storage system consists of photovoltaic panels , inverters, [Note] battery packs, master control switches, Gateway, loads, power grids, etc. The main function of Home energy storage system is to store the direct ...
Page 16
User Manual Under backup power networking, the duration of off-grid operation of the backup power load is related to the power supply capacity of the PV storage system. If there is an abnormality in the power supply of the PV storage system during off-grid operation (including but not limited to abnormal PV power generation, insufficient battery power, and abnormal power supplies to the diesel generator), the backup power load will still be unable to operate.
Page 17
User Manual As a backup energy source for long-term off-grid applications, the diesel generator can work in tandem with the Gateway to provide a smooth transition between PV, storage and diesel power generation. All the power equipment in the owner's home can be connected as smart ...
Page 18
User Manual Networking Diagram (Partial Home Backup) A. PV panel SigenStor EC D. Gateway SigenStor BAT Backup Distribution panel Non-Backup Distribution panel Backup Home loads G. Diesel Non-Backup Home loads Generator H. Smart loads Power sensor Power grid mySigen Router Antenna CommMod As a backup energy source for long-term off-grid applications, the...
Page 19
User Manual loads (heat pumps, pool heaters, clothes dryers, immersion heaters, etc.), which can be cut off when the energy storage system has low power. Other low-power equipment are connected as home loads (lights, routers, etc.) The maximum power for an immersion heater should be ≤ 17.6 kW/80 A. Power sensor has the function of data acquisition for grid connection ...
Page 20
User Manual Networking Diagram (Non-backup Networking) A. PV panel B. SigenStor EC C. SigenStor BAT D. AC switch E. Distribution panel F. Home loads G. Power sensor H. Power grid I. mySigen J. Router K. Antenna L. CommMod The rated voltage of the AC switch connected to each inverter should be ...
Page 21
User Manual The rated voltage of the AC switch of the distribution panel should be not less than 240 Va.c., and the rated current is recommended, that is, not less than the maximum output current of an inverter × the number of inverters in parallel connection ×...
Page 22
User Manual Site Selection Requirements The equipment can be installed indoors and outdoors. Install the equipment in strict accordance with installation instructions given in this section and local laws and regulations. The warranty applies when the equipment has been installed properly for ...
Page 23
User Manual Do not tilt or overturn the equipment to ensure that it is installed horizontally. Do not install the equipment in places easily touched by children. Do not install the equipment in places with fire or damp. ...
Page 24
User Manual The maximum operating temperature range applicable to the equipment is -20°C to 55°C, and the recommended optimal operating temperature range is 10°C≤T≤35°C. When the battery pack temperature is below 0°C, immediate charging is not possible, and the battery pack (the built-in heating module can be automatically enabled) will activate the heating feature automatically.
Page 25
User Manual Equipment Installation and Wiring Only company authorized personnel should install and connect the equipment. For details, see SigenStor-5S-(5-16), SigenStor-6S-(8-24) Installation Guide. Parts and accessories supplied with the packing box are personal assets of the owner and must be kept safe. 25 / 38...
User Manual System Operation Working Mode There are four operating modes of the energy storage system: Sigen AI Mode, Fully Fed to Grid Mode,Self-Consumption Mode, Time-based Control Mode. Sigen AI Mode can be used in some countries, which is explicitly stated on ...
Page 27
User Manual maximum output capacity of the inverter or when no PV power is generated at night, the batteries are discharged to ensure that the inverter can maximize the output. Self-Consumption Mode When there is sufficient solar power, the electric energy generated by the PV system will first be used to power the loads, with any excess energy being stored in the batteries.
Page 28
User Manual Backup Reserve: If there is a Gateway in the network, you can manually set the "Backup Reserve" value in mySigen App. When the grid is connected, the battery stops discharging when the set backup SOC is reached; when the grid is powered down, the battery power from the backup can be used.
User Manual 5.2 LED Indicator State Indicator Color State Description Always on The DC side is connected but not running. Always on The DC side is running. The DC side is not connected. Flash The DC side is faulty. Always on Inverter failure.
Page 30
User Manual Indicator Color State Description The management system is not connected. Flash Connected to local App. Always on Connected to the management system using an FE or WLAN. Always on Connected to the management system over 4G. Flash Insufficient traffic for Sigen CommMod. 30 / 38...
User Manual System Maintenance 6.1 Routine Maintenance To ensure the long-term running of the equipment, you are advised to perform routine maintenance according to this section. Inspection Inspection method Power off Maintenance content or not cycle System Check the decorative cover regularly Once every cleaning for shielding and dirt.
User Manual 6.2 Equipment Powering-on/Power-off Scheme 1: App operation Tap "Setting" in mySigen App to turn on/off the device. Scheme 2: Manual operation Follow the steps shown to remove the side and top decorative cover, and press the ON/OFF switch button. Press and hold for more than 3s to turn on or off the power;...
Page 34
User Manual In case of prolonged inactivity of the equipment (such as being offline for several consecutive days or having minimal operational hours), the system will issue a reminder. If no feedback is received from you, the equipment will be automatically turned off as a precautionary measure for safety.
User Manual 6.3 Low SOC The self-discharge characteristic of battery pack will cause power loss. If the equipment is not charged for a long time, it may be damaged due to overdischarge of power. When the battery is low, charge the equipment in time. Under normal circumstances, the equipment can charge itself according to the running condition.
User Manual 6.4 Emergency Treatment Emergency Measures for Fire Please shut down the equipment or disconnect the main power switch when it is safe. The high temperature may distort or damage the battery pack, resulting in electrolyte overflow or toxic gas leakage. Do not go near the battery pack and wear protective equipment.
Page 37
User Manual Emergency Measures for Battery Pack Exceptions When the battery pack has abnormal odor, electrolyte leakage, or heat, do not touch it, and contact professional personnel immediately. Professionals must wear protective equipment such as goggles, rubber gloves, gas masks, and protective clothing to protect themselves.
User Manual Appendix 7.1 Technical Parameter Item SigenStor 5S-(5-16) SigenStor 5S-(8-24) Pollution degree PD2, PD3 Back feed current 21.7 A Inrush current 28.7 A Max. output overcurrent 32.5 A 43.0 A protection Max. output fault current 65.0 A 86.0 A For other parameters of the equipment, please refer to their respective data sheets.
Need help?
Do you have a question about the SigenStor-5S-5 and is the answer not in the manual?
Questions and answers