User Manual Overview Introduction The focus of this document is to provide an overview of the Sigen Hybrid/SigenStor EC (8.0-12.0) SP AU inverter, including product features, network ing, system operation, maintenance, etc. Readers This document is suitable for product users and professionals Sign Definition The following signs may be used in the document to indicate security precautions or key information.
User Manual Chapter 1 Safety Precautions Basic Information Before installing, operating, and maintaining the equipment, familiarize yourself with this document. The "Danger ", "Warning", "Caution" items described in this manual are only supplementary to all precautions. The Company shall not be liable for equipment damage or property loss caused by the following reasons: Failure to obtain approval from the national, regional power authority.
User Manual The equipment was stolen. The equipment is damaged after the warranty period. Safety Requirements Do not expose the device to high temperature or heat sources (such as sunlight, fire, or heaters) around the equipment for a long time. ...
Product Model Product Function Model No. Name code specification Inverter; it can be used in Sigen Hybrid 8.0 SP Sigen Hybrid Inverter conjunction with 8.0 kW Single Phase PV modules for pure PV applications or in combination with Sigen PV modules and Sigen Hybrid 10.0 SP...
Page 9
User Manual after the SigenStor EC 12.0 SP Sigen Hybrid Inverter purchase and 12.0 kW Single Phase activation of a license. 9 / 26...
User Manual 2.3 Label Description Symbols Definition Danger! High Voltage High voltage exists inside the equipment when powered on. Do not open the casing when the equipment is running. Any maintenance or servicing operations must be performed by trained and skilled electrical engineers. Warning! Life at risk.
User Manual Supported Power Supply Methods for the Power Grid The grid supply methods supported include TN-S, TN-C, TN-C-S, and TT. When TT is used as the power supply technique for the power grid, the voltage between N and PE is required to be < 30 V. 13 / 26...
H. Router I. Antenna J. CommMod Sigen PV Max or Sigen Hybrid supports a maximum of 20 units in cascade connection. The rated voltage of the AC switch connected to each inverter should be ≥ 240 Va.c. and the rated current is recommended: ...
Page 15
User Manual Sigen Hybrid (10.0-12.0) SP AU: The rated current is 63 A It is recommended to use FE and WLAN for communication with inverter. When free 4G traffic of CommMod runs out, users must top up their accounts or replace an SIM card.
User Manual Chapter 3 Site Selection Requirements The warranty applies when the equipment has been installed properly for its intended use and in accordance with the operating instructions. During actual installation, the selection of installation location should comply with local firefighting, environmental protection regulations, and other relevant laws.
User Manual The equipment produces sound when it is operating. Please install the equipment in a place far away from your daily work and daily life. Do not install the equipment in a sealed, poorly ventilated location without fire protection measures and difficult access for firefighters. The equipment is hot when it is running.
Equipment Installation and Wiring Only company authorized personnel should install and connect the equipment. For details, see Sigen Hybrid (8.0-12.0)SP AU Installation Guide. Parts and accessories supplied with the packing box are personal assets of the owner and must be kept safe.
User Manual Chapter 5 System Operation 5.1 LED Indicator State Indicator Color State Description Always on The DC side is connected but not running. Always on The DC side is running. The DC side is not connected. Flash The DC side is faulty. Always on The inverter is faulty.
User Manual Chapter 6 System Maintenance 6.1 Routine Maintenance To ensure the long-term running of the equipment, you are advised to perform routine maintenance according to this section. Inspection Inspection method Power off Maintenance content or not cycle System Regularly check whether the Once every cleaning decorative cover or fan is covered...
User Manual 6.2 Equipment Powering-on/Power-off Scheme 1: App operation In the mySigen app, tap "Settings" to turn the device on or off. Scheme 2: Manual operation Follow the steps shown to remove the side and top decorative cover, and press the ON/OFF switch button.
Page 24
User Manual 4. After all LED indicators on the equipment go off, wait for the corresponding time as indicated on the label on the equipment before proceeding. In case of prolonged inactivity of the equipment (such as being offline for several consecutive days or having minimal operational hours), the system will issue a reminder.
User Manual 6.3 Emergency Treatment Emergency Measures for Fire Please shut down the equipment or disconnect the main power switch when it is safe. If the fire is small, use carbon dioxide or ABC dry powder extinguisher to extinguish the fire.
Environmental category:outdoor, indoor conditional, indoor unconditional; backfeed current: 0A; For SigenStor EC 8.0 SP AU or Sigen Hybrid 8.0 SP AU , the inrush current is 40.0 A, the Max. output overcurrent protection is 40.0 A, the Max. output fault current is 88.0 A;...