Page 1
Installation and operating instructions ELECTRIC BAIN-MARIE FOR PROFESSIONAL USE BM-94EMT BM-98ETT Model LIBR.ISTR.S90D BM-ETT Code 5630600A0 Review 1 Edition date 08/11/2024 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
Contents Contents INTRODUCTION ......................... Installation drawing ........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 BM-94EMT BM-98ETT A Data Plate B Electrical connection D Water connection R 1/2"M E Water drain R 1"M F Energy saving connection Translation of the original instructions...
Page 4
INTRODUCTION WIRING DIAGRAM BM-94EMT 230V~ 50/60 Hz Translation of the original instructions...
Page 5
INTRODUCTION Single-phase power supply terminal block Power switching terminal block Three-phase power supply terminal block Single-pole switch Transformer Contactor Water solenoid Relay Optimiser connection Digital control board K-type thermocouple temperature probe Resistance switching terminal block Resistance Translation of the original instructions...
Page 6
INTRODUCTION WIRING DIAGRAM BM-98EMT 400V~2N 50/60 Hz Translation of the original instructions...
Page 7
INTRODUCTION Single-phase power supply terminal block Power switching terminal block Three-phase power supply terminal block Single-pole switch Transformer Contactor Water solenoid Relay Optimiser connection Digital control board K-type thermocouple temperature probe Resistance switching terminal block Resistance Translation of the original instructions...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
Technical data table Technical data table BM S90ETT MAXIMUM MAXIMUM POWER CABLE MODEL DIMENSIONS POWER SUPPLY ABSORPTION (A) POWER (kW) silicon type BM-94EMT 40x90x90h 230V~50/60 Hz 9.13 3 x 1.5 mm² BM-98ETT 80x90x90h 400V~2N 50/60 Hz 8.26 4 x 1.5 mm² ...
Page 11
GENERAL INFORMATION DESIGN ASSEMBLY/TRANSFORMATION ELECTRICAL LINKING TERMINAL BLOCK PERNIONS (see technical data table) · POWER SUPPLY CONNECTION · HEATING ELEMENT CONNECTION Translation of the original instructions...
Page 12
GENERAL INFORMATION Parameter table BM-9..ETT PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field MAX temp. Maximum temperature 50 - 400 °C NTC temperature for cooling Fan temp. setting 0-50 °C fan(s) start-up Enabling of instrument compartment cooling fan(s) start-up: Cooling fan 0=always off 1=always on 2=as in parameter 2...
Page 13
GENERAL INFORMATION PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field Calculation limit of the PID KI constant. % referring to the PID TR (15) and defines the MaxOut PID_I maximum value of the ON time 20 - 80 component, calculated from the Integrative component alone.
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations. Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
INSTALLATION Caution ALL PARTS THAT GIVE ACCESS TO LIVE PARTS AFTER REMOVAL ARE MARKED WITH THE "WARNING: DANGEROUS VOLTAGE" SYMBOL Water connection and drainage · It is advisable to connect the appliance to the hot water pipe (max. 60 °C) to reduce heating times; we also recommend installing a shut-off valve up-line of the appliance ·...
INSTRUCTIONS FOR USE 4 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE Emptying the tank To perform this operation, open the drain tap (lever in vertical position) which can only be reached from the door of the cabinet underneath the appliance Note It is advisable to perform this operation using water that is not excessively hot ...
MAINTENANCE 5 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current regulations and our own instructions.
Page 20
MAINTENANCE Warning MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME: Close the gas cock and/or disconnect the power supply. Clean the system as specified above. Translation of the original instructions...
CLEANING 6 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.
Need help?
Do you have a question about the BM-94EMT and is the answer not in the manual?
Questions and answers