Lotus BRM80-98ETT Installation And Operating Instructions Manual

Professional electric braising pan

Advertisement

Quick Links

Installation and operating instructions
PROFESSIONAL ELECTRIC
BRAISING PAN
BRM80-98ETT BRM120-912ETT
Model LIBR.ISTR.S90D BRM-ETT
Code 5630602A0
Review 1
Edition date 12/11/2024
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRM80-98ETT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lotus BRM80-98ETT

  • Page 1 Installation and operating instructions PROFESSIONAL ELECTRIC BRAISING PAN BRM80-98ETT BRM120-912ETT Model LIBR.ISTR.S90D BRM-ETT Code 5630602A0 Review 1 Edition date 12/11/2024 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
  • Page 2: Table Of Contents

    Contents Contents INTRODUCTION ......................... Installation drawing ........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
  • Page 3: Introduction

    INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 BRM80-98ETT A Data Plate B Electrical connection D Cold water connection ISO 7-1 3/4"M   Translation of the original instructions...
  • Page 4 INTRODUCTION FIG. 2 BRM120-912ETT A Data Plate B Electrical connection D Cold water connection ISO 7-1 3/4"M   Translation of the original instructions...
  • Page 5 INTRODUCTION FIG. A WIRING DIAGRAM BRM80-98ETT BRM120-912ETT 400V~3N 50/60 Hz Translation of the original instructions...
  • Page 6 INTRODUCTION Electrical technical data table Three-phase power supply terminal block Power switching terminal block Capacitor Transformer Contactor Optimiser connection Safety thermostat Digital control board K-type thermocouple temperature probe Resistance switching terminal block Lift motor Digital relay board Resistance Microswitch Water solenoid  ...
  • Page 7: Example Installation Of The Appliance

    INTRODUCTION Example installation of the appliance Translation of the original instructions...
  • Page 8: General Information

    GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 9: User Information, Raee Directive On Waste Electrical And Electronic Equipment

    MAXIMUM MAXIMUM TANK DIMENSION POWER CABLE MODEL POWER SUPPLY ABSORPTION POWER CAPACITY silicon type (kW) (litres) BRM80-98ETT 80x90x90h 400V~3N 50/60 Hz 17,32 12,1 5 x 1,5 mm² BR120-912ETT 120x90x90h 400V~3N 50/60 Hz 26,12 18,1 5 x 2,5 mm²   Translation of the original instructions...
  • Page 10 GENERAL INFORMATION Table of parameters BRM-9..ETT PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field MAX temp. Maximum temperature 50 - 400 °C NTC temperature for cooling Fan temp. setting 0-50 °C fan(s) start-up Enabling of instrument compartment cooling fan(s) start-up: Cooling fan 0=always off 1=always on...
  • Page 11 GENERAL INFORMATION PARAMETER Adjustment ID code DESCRIPTION U.M. Resol. field Calculation limit of the PID KI constant. % referring to the PID TR (15) and defines the MaxOut PID_I maximum value of the ON time 20 - 80 component, calculated from the Integrative component alone.
  • Page 12: Installation

    INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 13 INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations.   Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
  • Page 14: Water Connection

    INSTALLATION Caution ALL PARTS THAT GIVE ACCESS TO LIVE PARTS AFTER REMOVAL ARE MARKED WITH THE "WARNING: DANGEROUS VOLTAGE" SYMBOL     Water connection · It is advisable to connect the appliance to the hot water pipe (max. 60 °C) to reduce heating times; we also recommend installing a shut-off valve up-line of the appliance  ...
  • Page 15: Instructions For Use

    INSTRUCTIONS FOR USE 4 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 16: Safety Thermostat

    INSTRUCTIONS FOR USE   Safety thermostat The appliance is equipped with a safety thermostat which interrupts the electrical circuit if the temperature of the tank exceeds the maximum preset value (420°). If this happens, operation can be resumed by fully pressing the red button on the safety thermostat.
  • Page 17: Maintenance

    MAINTENANCE 5 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current regulations and our own instructions.
  • Page 18 MAINTENANCE Warning MEASURES TO BE TAKEN IF THE APPLIANCE IS NOT TO BE USED FOR A LONG TIME: Close the gas cock and/or disconnect the power supply. Clean the system as specified above. Translation of the original instructions...
  • Page 19: Cleaning

    CLEANING 6 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden   To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.