Advertisement

Quick Links

Installation and operating instructions
GAS PASTA COOKER FOR
PROFESSIONAL USE
CP-74G CP-76G CP-78G CPA-74G CPA-76G CPA-78G CPT-74G CPT-76G
Model LIBR.ISTR.CP70G CON SIC.
Code 563006602
Review 1
Edition date 19/11/2018
Language English
LOTUS S.p.A.
Via Calmaor, 46
31020 San Vendemiano
+39 0438 778020
+39 0438 778277
Translation of the original instructions

Advertisement

Table of Contents
loading

Summary of Contents for Lotus CP-74G

  • Page 1 Installation and operating instructions GAS PASTA COOKER FOR PROFESSIONAL USE CP-74G CP-76G CP-78G CPA-74G CPA-76G CPA-78G CPT-74G CPT-76G Model LIBR.ISTR.CP70G CON SIC. Code 563006602 Review 1 Edition date 19/11/2018 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020...
  • Page 2: Table Of Contents

    Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................User information, RAEE Directive on waste electrical and electronic equipment ......Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation .........................
  • Page 3: Introduction

    INTRODUCTION 1 INTRODUCTION Installation drawing FIG. 1 CP-74G, CP-78G, CPA-74G, CPA-78G A Data Plate B Electrical connection C Gas connection D Water connection R 3/4"M E Water drain R 1"M   Translation of the original instructions...
  • Page 4 INTRODUCTION FIG. 2 CP-76G , CPA-76G A Data Plate B Electrical connection C Gas connection D Water connection R 3/4"M E Water drain R 1"M   Translation of the original instructions...
  • Page 5 INTRODUCTION CPT… A Data Plate C Gas connection Translation of the original instructions...
  • Page 6: Components

    INTRODUCTION Components FIG. A 1 Tap knob 2 Red indicator light 3 Power button 4 On-off switch 5 Hole for indicator light 6 Water discharge   Translation of the original instructions...
  • Page 7 INTRODUCTION FIG. C 1 By-pass   FIG. B CP... Water filling tap   FIG.D 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage 5 Injector   Translation of the original instructions...
  • Page 8 INTRODUCTION WIRING DIAGRAM CP-74G CP-76G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Gas solenoid 5 Power button 6 Bipolar switch 7 Power supply terminal board 8 Level probe 9 Red warning light...
  • Page 9 INTRODUCTION WIRING DIAGRAM CPA-74G CPA-76G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Bipolar diverter 5 Water solenoid 6 Gas solenoid 7 Bipolar switch 8 Illuminated bipolar switch 9 Power supply terminal board 10 Level probe 11 Red indicator light Translation of the original instructions...
  • Page 10 INTRODUCTION WIRING DIAGRAM CP-78G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Gas solenoid 5 Power button 7 Power supply terminal board 6 Bipolar switch 8 Level probe 9 Red warning light Translation of the original instructions...
  • Page 11 INTRODUCTION WIRING DIAGRAM CPA-78G 1 Ignition spark plug 2 Burner ignition control unit 3 Water level control unit 4 Bipolar diverter 5 Water solenoid 6 Gas solenoid 7 Bipolar switch 8 Illuminated bipolar switch 9 Power supply terminal board 10 Level probe 11 Red indicator light Translation of the original instructions...
  • Page 12: Example Installation Of The Appliance

    INTRODUCTION Example installation of the appliance Translation of the original instructions...
  • Page 13: General Information

    GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
  • Page 14: User Information, Raee Directive On Waste Electrical And Electronic Equipment

    Electrical technical data table CP S70G MAXIMUM MAXIMUM POWER SUPPLY MODEL POWER SUPPLY ABSORPTION ELECTRIC CABLE POWER (kW) silicon type CP-74G 230V~ 50/60 Hz 0,02 3 x 1 mm² CP-76G 230V~ 50/60 Hz 0,02 3 x 1 mm² CP-78G 230V~ 50/60 Hz 0,04 3 x 1 mm²...
  • Page 15: Installation

    INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following:   · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
  • Page 16 INSTALLATION Warning Installation operations, any conversion to other types of gas and start-up must only be   performed by qualified personnel, in accordance with current regulations.   Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
  • Page 17 INSTALLATION valve and fast-closing valve. Once installation is complete, make sure that there are no gas leaks from the fittings; to do this, do not use a naked flame but substances that do not cause corrosion, such as solutions of soapy water or leak detectors.
  • Page 18 INSTALLATION - "A" type devices (see data plate)   "A" type appliances must discharge combustion products into appropriate hoods, or similar devices, connected to an efficient fume stack or directly to the outside. (Natural evacuation) Fig. 1 If this is not possible, using an air suction device connected directly to the outside is permitted (Forced Evacuation) Fig.2, having a flow capacity not lower than the value defined in point 4.3 of the UNI-CIG 8723 standard.
  • Page 19: Water Connection And Drainage

    INSTALLATION 1 Windproof fume stack (fig.3) - Extractor hood (fig.4) 2 Servo system   "B11" type appliances are supplied on request with a hood or a hood and windproof fume stack to be assembled and delivered separately. Water connection and drainage ·...
  • Page 20: Burners Technical Data Table (Itgb)

    12.87 kWh/KG 9.45 kWh/m3st.   BUTANE PROPANE METHANE H 30 mbar 37 mbar 20 mbar CP-74G       (Burner 9.5 kW min. 4.8 kW) Burner injector 1/100 mm 1 x 160 1 x 160 1 x 235 Minimum adjustment 1/100 mm...
  • Page 21: Instructions For Use

    INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
  • Page 22: Starting The Main Burner And Adjusting The Temperature

    INSTRUCTIONS FOR USE Starting the main burner and adjusting the temperature · Turn the knob into position to set the burner to maximum · Turn the knob into position to set the burner to minimum Switching the main burner off ·...
  • Page 23: Top Appliances Bowl Emptying

    INSTRUCTIONS FOR USE Top appliances bowl emptying · The user is required to have a suitable recipient for emptying the water/oil · Insert the drain tube as shown on the drawing, position the container · Push the safety device upwards against the involuntary openings (A) and move the lever (B)  ...
  • Page 24: Characteristics Of The Feed Water

    INSTRUCTIONS FOR USE · Slow refilling button   When the "slow refilling button" is active, the system fills the tank slowly to prevent possible foaming   · Level button   The "level button" defines the level of water in the tank: high level for cooking pasta, low level for steaming  ...
  • Page 25: Maintenance

    MAINTENANCE 6 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract.   Caution Maintenance must only be performed by specialist personnel in compliance with current  ...
  • Page 26: Minimum Setting

    MAINTENANCE Warning After conversion to another type of gas, update the technical data plate to indicate the type of   gas for which the appliance has been converted. Minimum setting · After conversion to use another type of gas, or if a flame is too high when the knob is in position small flame), adjust the minimum setting by turning the by-pass screw.
  • Page 27: Cleaning

    CLEANING 7 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden     To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.

Table of Contents