Frequency inverter with integrated sine filter for 1 fans (87 pages)
Summary of Contents for ZIEHL-ABEGG ZETADYN 3-HY
Page 1
ZETADYN 3-HY Frequency inverter for hydraulic elevators Brief Instructions Additional information to the operating instructions ZETADYN 3BF (R-TBA05_08-GB) and ZETADYN 3C (R-TBA08_03-GB) R-TBA10_02-GB 1144 Part.-No. 00163347-GB...
Necessary modifications are incorporated into the next version. Ziehl-Abegg is not liable for damage due to misuse, incorrect use, improper use or as a consequence of unauthorized repairs or modifications. 2 Safety instructions...
Brief Instructions ZETADYN 3-HY Mechanical installation 4 Mechanical installation General notes The general information in chapter " Mechanical Installation" in the operating instructions R-TBA05_08 or R-TBA08_03 must be followed! Dimensions Dimensions ZETADYN 3BF018-HY and ZETADYN 3BF025-HY Dimensions ZETADYN 3BF032-HY to ZETADYN 3BF050-HY...
Brief Instructions ZETADYN 3-HY Electrical installation 5 Electrical installation Safety precautions The safety instructions described in chapter Electrical Installation of the operating instructions R-TBA05_08 or R-TBA08_03 must be followed! Connection suggestion ZETADYN 3BF-HY R-TBA10_02-GB 1144 Part.-No. 00163347-GB 6/19...
Brief Instructions ZETADYN 3-HY Start-up Connection Impulse encoder (X-ENC9) The inkremental encoder has to be connected to X-ENC9. Encoder cables of different lengths are available for connecting the impulse encoder. Article-Number Lenght GL03-ZA-ASM-BU 00165660 GL06-ZA-ASM-BU 00165661 GL10-ZA-ASM-BU 00165662 10 m Caution! The pin assignment of the SUB-D socket X-ENC9 is not standardized.
Information When a Ziehl-Abegg motor is purchased in connection with a frequency inverter, the motor specifications are already pre-programmed. Always review the specifications before the first travel. M o t o r n a m e p l a t e L C D &...
Brief Instructions ZETADYN 3-HY Start-up Information If the changing of an parameter has effect to the values of the Motor-Modell, after the confirmation of the input the No-load current(I0), Rotor time constant (Tr) and the Stator resistor wil be displayed The Indication must be confirmed again with the...
Brief Instructions ZETADYN 3-HY Enclosure Error diagnosis For error diagnosis and elimination the operating instructions R-TBA05_08 or R-TBA08_03 provide the chapter "Error diagnosis". In this chapter the possible errors and their elimination are described. 7 Enclosure Technical data 7.1.1 ZETADYN 3BF018 - 040-HY...
Brief Instructions ZETADYN 3-HY Enclosure Type designation 0xx - 1 ZETADYN Series 3rd generation Structure Basis unit for synchronous and asynchronous motors not including line reactor, radio interference filter and motor contac- tors Complete unit for asynchronous motors Including power choke, filter and motor contactors and brake contac-...
Need help?
Do you have a question about the ZETADYN 3-HY and is the answer not in the manual?
Questions and answers