Replacement of the frequency inverter with the frequency inverter (22 pages)
Summary of Contents for ZIEHL-ABEGG AM-MODBUS-WB
Page 1
AM-MODBUS-WB Part.-No. 349077 Bluetooth communication module for frequency inverters from the Basic series and fans from the ECblue (D+G), AMblue and PMblue series Quick Start Guide Attention, electrostatically sensitive components! Note chapter mounting the module. L-BAL-E281-GB 2021/36 Index 004...
We do not accept any liability for possible errors or omissions in the information con- tained in data, illustrations or drawings provided. ZIEHL-ABEGG SE is not liable for damage due to misuse, incorrect use, improper use or as a consequence of unauthorized repairs or modifications.
Quick Start Guide AM-MODBUS-WB General notes 1.3 Using in Europe The module comply with the Radio Equipment Directive (RED) 2014/53/EU. • Article 3.1[a]: Protection of health and safety of persons and of domestic animals – ETSI EN 300 328 V2.1.1 –...
Caution The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by ZIEHL-ABEGG SE may void the user's authority to operate the equipment. Changes or modifications not expressly approved by the party responsible for compli- ance could void the user's authority to operate the equipment.
Nevertheless, the PAN1740 shall be used in such a manner that the potential for human contact during normal operation is minimized 1.4.2 Industry Canada Certification @ AM-MODBUS-WB, AM-STICK-WB This device contains "Contains IC: 216Q-1740". PAN1740 is licensed to meet the regulatory requirements of Industry Canada (IC), license: IC: 216Q-1740.
The module is NCC approved for use in Taiwan. It meets the requirements of the Low- Power-Radio-Frequency Devices Technology Regulations as detailed in NCC LP0002 (2020) Section 4.10.1. Test report for AM-MODBUS-WB see CN21RFOW. NCC approval mark and identification number for AM-MODBUS-WB L-BAL-E281-GB 2021/36 Index 004 Part.-No.
Quick Start Guide AM-MODBUS-WB Safety instructions 2 Safety instructions Information Mounting, electrical connection, and start-up operation may only be carried out by an electrical specialist in accordance with electrotechnical regulations (e.g. EN 50110 or EN 60204)! Danger due to electric current •...
Customers who sell or use these ZIEHL-ABEGG products for these applications do so at their own risk. They undertake to reimburse ZIEHL-ABEGG in full for any possible costs that may occur.
Quick Start Guide AM-MODBUS-WB Mounting the module 3.3 Transport • The device is packed ex factory to suit the transport method previously agreed. • The device may only be transported in the original packaging. • Avoid shocks and impacts to the device during the transport.
Page 12
= 0.24 Nm. " When an AM-MODBUS-W/WB module is installed in a fan or converter from " ZIEHL-ABEGG, the enclosed label must be stuck to the housing of the terminating device. – "FCC/IC" label for AM-MODBUS-W – "FCC/IC" label for AM-MODBUS-WB Example for mounting the add-on module Example: Sticking the "FCC/IC"...
Quick Start Guide AM-MODBUS-WB Installation 5 Installation 5.1 Safety precautions Danger due to electric current • Work on electric components may only be carried out by trained electricians or by persons instructed in electricity under the supervision of an electrician in accordance with electrical engineering regulations.
Quick Start Guide AM-MODBUS-WB Installation 5.3 RS-485 interface for MODBUS The device comes equipped with a RS-485 interface for networking via MODBUS. Conntection at: “A (D+)”, “B (D-)” and “GND”. MODBUS MODBUS MODBUS MODBUS (RS-485) (RS-485) (RS-485) (RS-485) (D+) (D-)
Quick Start Guide AM-MODBUS-WB Installation If shielded cables are used, the shield should be placed at “PE” on at least one side (preferably on the master connection). The occurrence of compensating currents may have to be considered if the shield is contacted on both sides.
Page 16
Quick Start Guide AM-MODBUS-WB Installation The connection at the terminal is made at the terminals: A (D+), B (D-) and GND. Connection of the users via the terminals: A (D+), B (D-), GND and ID1 / ID2 Information • Except the data link “A (D+)”, “B (D-)” the “ID1 - ID2” and the “GND” connection may no further cable cores of the data line be used.
Quick Start Guide AM-MODBUS-WB Operating by terminal 6 Operating by terminal 6.1 Menu operation “Start” " Switch over between actual value* and with arrow key. “Start” " Switch over between and actual value* with key. * Actual value depending on device type: "Speed" / rpm, "Frequency" / Hz, "Modulation" / % “Start”...
Bluetooth® for wireless communication 7 Bluetooth® for wireless communication 7.1 AM-MODBUS-WB with Bluetooth version 4.0 The AM-MODBUS-WB includes a Bluetooth LE (BLE) module that enables the user to take advantage of the 4.0+ Bluetooth technology with an Android device, iPhone, iPad or laptop.
Quick Start Guide AM-MODBUS-WB Bluetooth® for wireless communication Technical data for wireless communication Frequency 2.4 GHz Communications range Approx. 10 m in rooms, up to 30 m in the free field, generally depends strongly on external influences and the installation sit- uation.
Page 21
Quick Start Guide AM-MODBUS-WB Bluetooth® for wireless communication Tap the “Add device” button and select Bluetooth to create a system with a Bluetooth " LE data connection. ZAset checks whether Bluetooth is activated on your smartphone, and prompts you to activate it if necessary.
Page 22
Quick Start Guide AM-MODBUS-WB Bluetooth® for wireless communication ZAset then starts searching for devices in range and adds compatible devices to a " list. Scanning process 3 Connections made Briefly tap the desired device in the list to select it. ZAset mobile then immediately "...
Page 23
Quick Start Guide AM-MODBUS-WB Bluetooth® for wireless communication Enter the PIN 9999 (factory setting acess code) and confirm with "OK". " " Set a new PIN to prevent unauthorised access. Setting PIN 9999 Change PIN L-BAL-E281-GB 2021/36 Index 004 Part.-No.
Page 24
Quick Start Guide AM-MODBUS-WB Bluetooth® for wireless communication If required, enter a name of your choice (alias). " Change alias Example: 01_ECblue " Touch the device's button to establish a connection. L-BAL-E281-GB 2021/36 Index 004 Part.-No. 24/28...
Page 25
Quick Start Guide AM-MODBUS-WB Bluetooth® for wireless communication Display of actual values on the dashboard when the connection is successful. " Buttons for subsequent operation can be found on the dashboard. 1 Menu: Start, List my devices, Settings 2 Info: BLE vesion, MODBUS address, identification etc.
Quick Start Guide AM-MODBUS-WB Diagnostic 8 Diagnostic 8.1 Status LEDs on the module There are three LEDs for the status display on the module: 1 Continuously lit when connected to the mains 2 Continuously lit when connected to the mains...
Page 27
Quick Start Guide AM-MODBUS-WB Enclosure 9 Enclosure 9.1 Connection diagram AM-MODBUS(-W)(-WB) PORT 1 PORT 2 ID1 GND ID2 f out (D+) (D-) (D+) (D-) n ~ f GND MODBUS Addressing (RS-485) MODBUS Addressing (RS-485) MOSI09K0 28.01.2020 fout Tacho output only active when used in ECblue (see Assembly Instructions)
Page 28
Quick Start Guide AM-MODBUS-WB Enclosure 9.2 Manufacturer reference Our products are manufactured in accordance with the relevant international regulations. If you have any questions concerning the use of our products or plan special uses, please contact: ZIEHL-ABEGG SE Heinz-Ziehl-Straße 74653 Künzelsau phone: +49 (0) 7940 16-0 info@ziehl-abegg.de...