ZIEHL-ABEGG FXET4AMQ Operating Instructions Manual
ZIEHL-ABEGG FXET4AMQ Operating Instructions Manual

ZIEHL-ABEGG FXET4AMQ Operating Instructions Manual

Frequency inverter with integrated sine filter for 1 fans
Table of Contents

Advertisement

Quick Links

english
Fcontrol
FXET4/6/10AMQ
Frequency inverter with integrated sine lter for 1 ~ fans
Operating Instructions
Keep for reference!
L-BAL-E079-GB 1706 Index 008
Part.-No.

Advertisement

Table of Contents
loading

Summary of Contents for ZIEHL-ABEGG FXET4AMQ

  • Page 1 english Fcontrol FXET4/6/10AMQ Frequency inverter with integrated sine lter for 1 ~ fans Operating Instructions Keep for reference! L-BAL-E079-GB 1706 Index 008 Part.-No.
  • Page 2: Table Of Contents

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Content General notes ............. Structure of the operating instructions .
  • Page 3 Operating Instructions Fcontrol – model series FXET4/6/10AMQ 5.11 Add-on module type Z-Modul-B Part-No. 380052 ......5.12 Connection of external Terminal type AXG-1A(E) .
  • Page 4 Operating Instructions Fcontrol – model series FXET4/6/10AMQ 9.9.5 Limit ............9.9.6 Minimum speed cut off .
  • Page 5 Operating Instructions Fcontrol – model series FXET4/6/10AMQ 14.3 Dimensions [mm] ........... . . 14.4 Index .
  • Page 6: General Notes

    We do not accept any liability for possible errors or omissions in the information contained in data, illustrations or drawings provided. ZIEHL-ABEGG SE is not liable for damage due to misuse, incorrect use, improper use or as a consequence of unauthorized repairs or modifications.
  • Page 7: Product Safety

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Safety instructions Danger due to electric current Danger by dangerous, electric voltage! Death or severe injury can occur if the corresponding precautions are not taken! Information Important additional information and advice for user. Product safety The device conforms to the state of the art at the time of delivery and is fundamentally considered to be reliable.
  • Page 8: Modifications / Interventions In The Device

    Use only genuine spare parts / genuine wearing parts / genuine accessories from ZIEHL-ABEGG.Th- ese parts were specifically designed for the device. There is no guarantee that parts from non-original sources are designed and manufactured in correspondence with load and safety requirements.
  • Page 9: Product Overview

    The name plate carries the technical data valid for the delivered product. Example for name plate Description Description Type designation Part no. ZIEHL-ABEGG brand name Serial number Type of voltage Production code Line voltage DATA MATRIX code serial number Mains frequency...
  • Page 10: Storage

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Mounting Storage • The device must be stored in its original packaging in a dry and weather-proof room. • Avoid exposure to extreme heat and cold. • Avoid prolonged storage; we recommend a maximum of one year (consult the manufacturer before starting if stored for longer).
  • Page 11: Minimum Space Requirement

    Fastening the device The type of fastening and the number of fastening points are dependent on the housing design. All the fastening points available must be used for safe fastening. Proceed as follows: Type FXET4AMQ Fastening at 3 points GM00006B_M 23.01.2017 Drill fastening point “1”.
  • Page 12: Cable Inlet

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Mounting Type FXET6/10AMQ Fastening at 4 points GM00005A_M 15.12.2015 " Drill fastening points “1” - “4”. Fasten device with screws. " Cable inlet Remove the terminal compartment cover. " " Depending on the housing model cut off necessary cable inlets respectively to the cable diameter. Or alternative use cable inlet for cable glands.
  • Page 13: Outdoor Installation

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Electrical installation Outdoor installation Outdoor installation is possible up to -20 °C when the controller supply is not switched off. Installation must be protected from the effects of weather as much as possible, including protection from direct sunlight! Installation location for agriculture When using for animal keeping, do not install the device directly in the stable but in a separate room...
  • Page 14: Terminal Compartment

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Electrical installation Terminal compartment Position of terminals 1 Line 2 Motor 3 Indication relays 4 Modulation 5 MODBUS EMC-compatible installation 5.3.1 Motor cable The applicable standard for interference emissions is EN 61000-6-3. Compliance with this standard is achieved through the use of an unscreened motor feed cable.
  • Page 15: Required Quality Attributes For The Mains Voltage

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Electrical installation 5.4.3 Required quality attributes for the mains voltage Danger due to electric current The mains voltage must comply with the EN 50160 quality characteristics and the defined standard voltages in IEC 60038! 5.4.4 Leakage current, securely attached, protective earth conductor Danger due to electric current...
  • Page 16: Signal Input Or Sensor Connection (E1, E2)

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Electrical installation Display during motor fault Motor fault Possibilities for re-starting after the drive has cooled down (terminals “TB” bridged) by: • By switching the mains voltage off and then on again. • By simultaneously depressing the three keys: P, ▲, ▼(if a fault is indicated).
  • Page 17: Add-On Module Type Z-Modul-B Part-No. 380052

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Electrical installation 5.11 Add-on module type Z-Modul-B Part-No. 380052 The expansion module can be retrofitted. This could be necessary if the analog and digital inputs and outputs are not sufficient for certain applications. The board is easy to install into the device and is connected with the control device via a plug.
  • Page 18: Communication

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Electrical installation 5.15 Communication 5.15.1 Networking via MODBUS-RTU The device comes equipped with a RS-485 interface for networking via MODBUS. Conntection at: “A (D+)”, “B (D-)” and “GND”. The address must be set in the “IO Setup”menu. Information A maximum of 64 members can be directly connected to one another, and another 63 members via a repeater.
  • Page 19: Lon ® Bus System Is Possible Via Add-On Module

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Electrical installation Shield connection correct Shield connection incorrect Default interface parameter Baudrate 19200 Bits Parity Even (None, exception of devices agriculture) Stop bits Handshake none Information If any matters are unclear, please contact our V-STE support department for control systems - ventilation technology.
  • Page 20: Controls And Menu

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Controls and Menu 6 Controls and Menu switches Power stack (fan) is switched off Auto Power stack in operation (standard position) 100 % Ventilators are operated directly from the mains with no control. Motor protection by thermostat connection input “TB”...
  • Page 21: Menu Operation

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Controls and Menu Menu operation Display after turning on the voltage supply. description for menu language English = “GB” (delivery status). Switch over between “Start” and *Actual value with Escape Example for mode 1.01 (speed controller).
  • Page 22: Menu Structure

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Controls and Menu Menu structure PIN 0010 STOP ← ← ← ← User Service → → → → ▼ ▼ ▼ ▼ ▲ ▲ ▲ ▲ Start Info Setting Events Base setup P↓ ↑ ESC P↓...
  • Page 23: Base Setup

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Base setup 7 Base setup Select operation mode Information Simple installation is possible through the selection of the preprogrammed mode of operation. This determines the basic function of the device; factory setting 1.01 = speed controller (activation via 0 - 10 V signal).
  • Page 24: External Setpoint / External Speed Setting In Manual Operation

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Base setup Mode and Signal to E1, E2 1.01 2.01 2.03 3.01 3.02 4.01 5.01 6.01 0 - 10 V TF.. MBG..-I MPG, DSG 0 - 10 V MAL 0 - 10 V 0 - 10 V 10 k MPG..
  • Page 25: Start-Up

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Start-up 8 Start-up Prerequisites for commissioning Attention! 1. You must mount and connect the device in accordance with the operating instructions. 2. Double check that all connections are correct. 3. The mains voltage must match the information on the rating plate. 4.
  • Page 26: Menu Overview Mode (Without Add-On Modules )

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Menu overview Mode 1.01 (without add-on modules ) Base Controller Motor Start Info Setting Events IO Setup Limits Diagnostic setup Setup Setup 50.0 Hz 6.0 A 1.01 0.0 Hz Set Inter- PIN Protec- Controller MotorRa- Mode...
  • Page 27: Setting For Operation 1.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.1.2 Setting for operation 1.01 Setting Setting Set Internal1 Setting range manual speed setting: “Min. Speed” - “Max. Speed” Factory setting: 50.0 Hz ( Setting “Max. Speed”) Set Internal1 Setpoint2 Setting “Set Intern2” e.g. reduced value for night operation. Switch over intern 1/2 by external contact (as long as no allocation is carried out: Setpoint2 Display:...
  • Page 28: Temperature Control 2.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Temperature control 2.01 2.05 9.2.1 Basic setting 2.01 2.05 Base setup Base setup Mode Mode selection e.g. 2.01 Mode E1 Analog In In all group 2 operating modes (2.01, 2.02, 2.03, ..) “E1 Analog In”...
  • Page 29: Settings For Operation Modes 2.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.2.2 Settings for operation modes 2.01 2.05 2.01 Temperature control simple 2.02 Temperature control depending on outdoor temperature (Special function: Sensor connection at “E2”, display and setting under “E1”). 2.03 Temperature control with pre-programmed additional functions (heating, shutter, temperature monitoring). 2.04 Temperature control with 2 sensors Comparison with control to higher value “E2 Function”...
  • Page 30: Functional Diagrams Temperature Control

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.2.3 Functional diagrams temperature control Example 1: Temperature control in factory setting “Cooling function” (Idealized principle diagram) 100 % Min. 0 % Max. = 100 % Min. 35 % Max. = 85 % 50 % Min.
  • Page 31: Additional For Mode 2.03 : Signal Output 0 - 10 V

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.2.4 Additional for mode 2.03 : Signal output 0 - 10 V The 0 - 10 V output signal can, e.g., be used for triggering a shutter or heating. Offset AnalogOut The target value for this output is the target value (Setpoint) for the ventilation “offset” Offset AnalogOut setting.
  • Page 32: For Mode 2.03 : Relay Output For Heating Or Cooling

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.2.5 For mode 2.03 : Relay output for Heating or Cooling OffsetDigitalOut Offset Digital Out = Offset for relay output (“K2” is pre-programmed by the factory). The relay operating point deviates by the adjusted offset of the Setpoint of the ventila- OffsetDigitalOut tion (if relay “K2”...
  • Page 33: Relay Output For Temperature Monitoring

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.2.6 For mode 2.03 Relay output for temperature monitoring If the set value for the “minimum alarm” is not reached or the set value for the “maximum alarm” is exceeded, a message is generated via the alarm symbol in the display. In addition, „Lmt E1 min“ is displayed alternately with the actual value for the minimum alarm and Lmt E1 max for the „Maximum alarm“.
  • Page 34: Pressure Control For Condensers Refrigeration 3.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Pressure control for condensers refrigeration 3.01 3.04 9.3.1 Base setup 3.01 3.04 Base setup Base setup Mode Mode selection e.g. 3.01 Mode E1 Analog In For all Modes in Group 3 ( 3.01 3.02 3.03...
  • Page 35: Setting For Operation Modes 3.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.3.2 Setting for operation modes 3.01 3.04 3.01 Pressure control condensers, setting Setpoint in bar 3.02 Pressure control for condensers with input for refrigerant, Setpoint in °C 3.03 Two sensors for dual circuit condenser. Automatic regulation to the highest pressure (selection amplifier integrated) operation display: “Control value”, Setpoint in bar 3.04 Two sensors for dual circuit condenser with input for refrigerant automatic regulation to the highest...
  • Page 36: Functional Diagrams Pressure Control Condensers

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.3.3 Functional diagrams pressure control condensers Functional diagram for Mode 3.01 3.03 (Idealized principle diagram) 100 % Min. 0 % Max. = 100 % 50 % Min. 17 bar 5 bar 12 bar 09.05.2007 v_diagramm_301_303_bar.vsd nM Motor speed...
  • Page 37: Pressure Control Airconditioning 4.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Pressure control airconditioning 4.01 4.03 9.4.1 Base setup 4.01 4.03 Base setup Base setup Mode Mode selection e.g. 4.01 Mode E1 Analog In In all group 2 operating modes 4 ( 4.01 4.02 4.03 , ..) “E1 Analog In”...
  • Page 38: Setting For Operation Modes 4.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.4.2 Setting for operation modes 4.01 4.03 • 4.01 pressure control, setpoint in Pa • 4.02 4.03 Pressure control for ventilation systems setpoint depending on outdoor temper- ature Setting Setting Setpoint1 Setting range: in measuring range of sensor Factory setting: 100 Pa Setpoint1 Setpoint2...
  • Page 39 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Additional menu item for mode 4.02 4.03 with outside-temperature dependent target- setpoint. Outside-temperature dependent target-setpoint An outside temperature compensation can be activated (sensor connection “E2” = “Analog In [Pa] 2”) when being operated as a pressure regula- tion device.
  • Page 40: Volume Control 5.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Volume control 5.01 5.02 9.5.1 Basic setting 5.01 5.02 Base setup Setting Mode Mode selection e.g. 5.01 Base setup E1 Analog In In all group operating modes 5 ( 5.01 5.02 ) “E1 Analog In” factory setting “DSG200.”...
  • Page 41 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Min. Speed (basic speed only when needed) Setting range: → “Shutdown Freq.” ( Motor Setup) - “Max. Speed”. Factory setting: Min. Speed Max. Speed (speed limitation only when needed) Setting range: “Max. Frequency” ( Motor Setup) - “Min.
  • Page 42: Air Velocity Control 6.01

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Air velocity control 6.01 9.6.1 Base setup 6.01 Base setup Base setup Mode Mode selection 6.01 Mode E1 Analog In For mode 6.01 “E1 Analog In” factory setting to “MAL1” Selection sensor measuring range: MAL1, MAL10 E1 Analog In Alternative selection signal: 0 - 10 V, 0 - 20 mA, 4 - 20 mA.
  • Page 43: Menu Group Start

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Max. Speed (speed limitation only when needed) Setting range: “Max. Frequency” ( Motor Setup) - “Min. Speed” Factory setting: 50.0 Hz Max. Speed Manual mode “OFF” = automatic control as function of the set parameters (Factory setting) “ON”...
  • Page 44: Menu Group Info

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Individual unit number SN: 000003CAF711 Version number internal motor controller Menu group Info Menu group Info Info Info for mode speed controller 1.01 Inverter output frequency. Frequency Display of motor current (Metering precision approx. +/-10%) Motor current Input power display (display available depending on the software version) Input power...
  • Page 45: Controller Setup

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Display of motor current (Metering precision approx. +/-10%) Motor current Input power display (display available depending on the software version) Input power Output power display (display available depending on the software version) Output power Momentarily status for minimum speed cut off “ON”...
  • Page 46: Limit

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming With “Alarm Sensors” = “OFF” (factory setting). Indicated sensor disturbances are displayed as “Message” alternating to the actual value and stored in the menu of “Events”. Alarm sensors Sensor 1 With “AlarmSensors” = “ON” areindicated sensor disturban- ces as “Alarm”...
  • Page 47: Second Group

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.9.7 Second Group Second group “indirectly controlled” (picture A) Analog output “AnalogOut 1” in IO Setup function = group control is programmed. This output is employed as the default signal for a speed controller. If the default signal Group 2 ON value or the regulation deviation exceeds the group 2 switch-on point, group 1 is reduced to “n-min group 2”.
  • Page 48: Controller Configuration

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.9.9 Controller configuration The “controller configuration” is automatically carried out during selection of the application related mode of operation (Base setup). The factory presets in accordance with the mode of operation are based on many years of experience, which is suitable for many applications.
  • Page 49: Io Setup

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10 IO Setup 9.10.1 Analog-Output “A” The analog outputs 0 - 10 V can be allocated with various functions. Terminals “A” - “GND” = Analog Out (I 10 mA) A Function With the attitudes “A min” and “A max” the characteristic of the output voltage can be adapted.
  • Page 50: Digital Inputs "D1" / "D2

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10.2 Digital inputs “D1” / “D2” 9.10.2.1 Menu overview The digital inputs Digital In 1 (D1) and Digital In 2 (D2) can be allocated with various functions. Activation via floating contacts (a low voltage of approx. 24 V DC is connected). D1 Function Inverting “D1”...
  • Page 51: Enable On/Off Function | 1D

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10.2.2 Enable ON/OFF function Remote ON/OFF (electronic disconnection) and Reset after a motor malfunction via floating contact. The power section is electronically disconnected. Operation of the device is still possible after pressing the “Esc” hotkey combination in switched-off condition. Signal- in and outputs remain active. •...
  • Page 52: Limit On / Off, Function

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10.2.4 Limit ON / OFF, Function The value for “Limit” adjusted in the Controller Setup, is activated over a digital input. Contact e.g. at ditgital input “Digital In 1” (depending on device type at terminals “D1” - “D1”or “D1” - “24 V”).
  • Page 53: Intern / Extern Function | 6D

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Operation with “Set Intern2” is signalized by the moon symbol for reduced operation. “Set extern1” under “settings” must be programmed to “OFF”. Frequency Switch over between “Setpoint1” and “Setpoint2” (for modes as controller higher 2.01 Contact e.g.
  • Page 54: Automatic Control / Speed Manual, Function | 7D

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10.2.8 Automatic control / speed manual, Function (mode 2.01 Switch over between automatic control to set target value (depending on the activation: “Setpoint1”, “Setpoint2”) and the default for “manual operation” set at the device. If for Analog In 2 “E2 function”...
  • Page 55: Setting Max. Speed On / Off Function | 11D

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10.2.11 Setting Max. Speed ON / OFF function The value for “Max Speed” adjusted in menu “Settings”, is activated over a digital input. I.e. the unit works independently of the controller function firm with this value. Contact e.g.
  • Page 56: Freeze Function" = Maintain Momentary Modulation Value, Function

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10.2.13 “Freeze function” = maintain momentary modulation value, Function The device continues to work so long independently of the control function with the momentary value of the modulation and/or speed as activated over the digital input. Message indicated alternating with the active value “Freeze Function”...
  • Page 57 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Example for Mode “1.01” with speed setting signal 0 - 10 V Modus 1 Modus 1 [Hz] Example: “E1 min.” = 20 % The controller begins only at approx. 20% higher signal with minimal modulation. E1 min.
  • Page 58: Inverting Analog Inputs "E1" / "E2

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10.3.2 Inverting analog inputs “E1” / “E2” After programming the signal or sensor type, an inversion of the inputs can be carried out. Factory setting for Inverting inputs = “OFF” (if input activated) (signal: 0 - 10 V, 0 - 20 mA, 4 - 20 mA).
  • Page 59 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Function Description No function Relays remain always de-energized Operating indication (factory setting for “K1”, non inverting). Operation without fault, reports enable “OFF” Fault indication (factory setting for “K2”, non inverting). Energized for operation without fault, for enable “OFF” not energized. De-energized at line, motor and controller fault, Sensor fault dependent on programming, external fault at digital input.
  • Page 60: Programming Add-On Module Type Z-Modul-B

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Function Controller status K1/ K2 1 = energized 0 = de-energized Inverting Operation without fault, line supply okay Fault with indication by relay Ext. Fault at digital input for external fault Over or falling below modulation over or falling below limits for input signal “E1”...
  • Page 61: Networking Via Modbus

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 9.10.6 Networking via MODBUS It is possible to network several devices with each other. The device uses the MODBUS-RTU as the protocol for the RS-485 interface. Bus Address The device address (Device-ID) is factory set to the highest available MODBUS address: 247 Bus Address Thisaddressis reserved for operation with an external terminal and should not be...
  • Page 62: Limit Indication Depending On Setting Or Sensor Signal

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Example indication by relay “K1”: not inverted Inverting IO Setup: K1 Function = 4K IO Setup: K1 Function = 4K IO Setup: K1 Inverting = OFF IO Setup: K1 Inverting = OFF 100 % 100 % 100 %...
  • Page 63: Limit Indication Depending On (Offset) To Setpoint

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Example for a limit indication of default signal or sensor signal to “Analog In 1” Settings: - E1 Max.: 80 % - E1 Min.: OFF - switching hysteresis 5 % (from Analog IN 100 %) 11.05.2007 50 %...
  • Page 64: Motor Setup

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Offset 1 for alarm during exceeding Offset 2 for alarm during undercutting OFF = 20°C - 2 K = 18 °C OFF = 15°C + 2 K = 17 °C ON = 15°C + 5 K = 20 °C ON = 20°C - 5K = 15 °C [min] [min]...
  • Page 65: Setting For Rampup Time And Rampdown Time

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Shutdown Freq. Below the Shutdown Freq. the output is switched off. Adjustment range: 5.0 - 150 Hz Shutdown Freq. Factory setting: 10.0 Hz Uout Ustart [Hz] Fedge 16.05.2007 Foff v_u_f_kennlinie.vsd Fmax Uout Output voltage Ustart Start-up voltage Foff Shutdown Freq.
  • Page 66: Setting Current Limit

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming 0 .. 100 % 09.05.2007 v_hochlaufzeit_ruecklaufzeit.vsd 1 external Signal 2 Setting 3 Rampup time 4 Rampdown time 9.12.5 Setting Current limit As an additional safety function the device has a current limit, this can be adapted if necessary.
  • Page 67: Setting Boost Value

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming DC brake level Direct-current voltage level, generated for braking. The higher this value, the greater the braking effect. The setting is dependent on the size of the ventilator / motor. DC brake level Attention! Values that are too high, will result in an excessive braking effect and possibly lead to actuation of the overload shutoff.
  • Page 68: Suppression Of Speeds

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Programming Indication: Overload1 If the modulation (frequency) of the device only corresponds to the value set in “Derating Alarm” due to too high an internal temperature, the fault indication “Over- Overload 1 load”is displayed. Behaviour of the relays “K1”...
  • Page 69: 10 Menu Tables

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Menu tables 10 Menu tables 10.1 Menues of operating modes Mode User Setting 2.01 4.01 3.01 3.03 5.01 1.01 2.03 2.02 2.05 4.02 6.01 3.02 3.04 5.02 2.04 4.03 Parameter Factory setting Start Motor PIN input - - - - -...
  • Page 70 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Menu tables Mode User Setting 2.01 4.01 3.01 3.03 5.01 1.01 2.03 2.02 2.05 4.02 6.01 3.02 3.04 5.02 2.04 4.03 Parameter Factory setting 2.03 = Offset AnalogOut 0.0 K 2.03 = Pband AnalogOut 2.0 K 2.03 = Min.
  • Page 71 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Menu tables Mode User Setting 2.01 4.01 3.01 3.03 5.01 1.01 2.03 2.02 2.05 4.02 6.01 3.02 3.04 5.02 2.04 4.03 Parameter Factory setting E2 K-Factor - - - - - E2 Min. - - - - - - - - - - - - - - -...
  • Page 72 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Menu tables Mode User Setting 2.01 4.01 3.01 3.03 5.01 1.01 2.03 2.02 2.05 4.02 6.01 3.02 3.04 5.02 2.04 4.03 Parameter Factory setting - - - - - D2 Inverting - - - - - - - - - - - - - - - - - - - -...
  • Page 73 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Menu tables Mode User Setting 2.01 4.01 3.01 3.03 5.01 1.01 2.03 2.02 2.05 4.02 6.01 3.02 3.04 5.02 2.04 4.03 Parameter Factory setting 2.03 = Lmt E1 Del. - - - - - - - - - - - - - - - - - - - -...
  • Page 74 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Menu tables Mode User Setting 2.01 4.01 3.01 3.03 5.01 1.01 2.03 2.02 2.05 4.02 6.01 3.02 3.04 5.02 2.04 4.03 Parameter Factory setting Filterchoke 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 E1-Temp.
  • Page 75: Possible Allocation Of The Ios, Pins

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Menu tables 10.2 Possible allocation of the IOs, PINs Analog outputs A / A2 Function Description Function A / A2 (Connection on Z-Modul-B, not A2 on motherboard) Constant voltage +10 V proportional level control proportional input E1 proportional input E2 Group control...
  • Page 76 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Menu tables Modus E1, E2 Description Function E min. / E max. without function Offset / turn Signal range Hysteresis setting ON / OFF (only E2) Function E2 Description Function Measurement Function E3 Description Function 0 - 10 V external Setpoint External Manual mode...
  • Page 77: 11 Diagnostics Menu

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Diagnostics menu PINs Function PIN 0010 Opening service menu, if PIN-protection activated PIN 1234 Opening “setting”. if “set protection” = “ON” ( Controller Setup) PIN 9090 Restore user setting PIN 9091 Save user setting (corresponds function “Save user setup” = “ON” Controller Setup) PIN 9095 Restore factory setting = delivery status...
  • Page 78 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Diagnostics menu E2-Current E2-Voltage Signal height at analog input E3 (Analog In 3*) Status digital input 1 (Digital In 1) OFF = terminals D1 - D1 bridged ↔ ON = terminals D1 - D1 not bridged Status digital input 2 (Digital In 2) OFF = terminals D2 - D2 bridged ↔...
  • Page 79: 12 Events / Fault Signals

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Events / Fault signals 12 Events / Fault signals 12.1 Display and query of events and malfunctions Events during operation can lead to a malfunctioning of the device. The last 10 (0 - 9) events and malfunctions are stored in the “Events” menu group (position “0”...
  • Page 80 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Events / Fault signals Display Code* LED Code Relais switches Cause Reaction of Controller Opera- Adjustment internal Failure tion Line voltage available? Unit switch OFF and automati- cally ON when the voltage has been restored No enable Switch OFF by external contact...
  • Page 81 Operating Instructions Fcontrol – model series FXET4/6/10AMQ Events / Fault signals Display Code* LED Code Relais switches Cause Reaction of Controller Opera- Adjustment internal Failure tion The unit then remains switched off. A programmed operating Tripping of connected ther- and fault-indicating relay is trig- mostat or break between gering terminals “TB”.
  • Page 82: 13 Function Extension And Version Of Software

    Rampdown time = 10 sec 1.06 DC brake mode = 1 DC brake time = 5 sec DC brake level = 10 % 14 Enclosure 14.1 Technical data Type FXET4AMQ FXET6AMQ FXET10AMQ Part-No. 308134 308157 308136 Rated current output {1} Rated current input {2} 10.8...
  • Page 83: Performance Reduction During Elevated Ambient Temperatures

    For installation in a switch cabinet, the device’s dissipation and its possible affect on the ambient temperature must be taken into consideration! Maximal motor current depending on ambient temperature 35 °C 40 °C 45 °C 50 °C 55 °C Type FXET4AMQ FXET6AMQ FXET10AMQ 10.0 10.0 10.0 10.0 L-BAL-E079-GB 1706 Index 008 Part.-No.
  • Page 84: Connection Diagram

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Enclosure 14.2 Connection diagram Fcontrol FXET4/6/10AMQ Adressierung / Addressing Normal Kontaktbelastung Contact rating Digital Digital Analog Analog Analog Analog Temp max. AC 250 V 2 A In 1 In 2 Out 1 Out 2 In 1 In 2 Eingang...
  • Page 85: Dimensions [Mm]

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ Enclosure 14.3 Dimensions [mm] FXET4AMQ FXET6/10AMQ L-BAL-E079-GB 1706 Index 008 Part.-No. 85/87...
  • Page 86: Index

    Operating Instructions Fcontrol – model series FXET4/6/10AMQ 14.4 Index Maximum frequency MBG-30I, MBG-50I address Minimum space requirement analog outputs Minimum speed cut off Average calculation MODBUS Mode motor feed cable Base setup motor leads bypass switching motor protection unit characteristic curve one-quadrantdrives control cable Outdoor installation...
  • Page 87: Manufacturer Reference

    Manufacturer reference Our products are manufactured in accordance with the relevant international regulations. If you have any questions concerning the use of our products or plan special uses, please contact: ZIEHL-ABEGG SE Heinz-Ziehl-Straße 74653 Künzelsau Telephone: +49 (0) 7940 16-0 Telefax: +49 (0) 7940 16-504 info@ziehl-abegg.de...

This manual is also suitable for:

Fxet6amqFxet10amq

Table of Contents