Web Guiding System Installation and Commissioning Manual ekr CON 600 ekr CON 600 net Application with Linear Position Sensor BTL5 MD.672.EN.01 Translation of the Original Manual...
Page 2
BST GmbH Remusweg 1 D-33729 Bielefeld Tel.: +49 (0) 521 400 70 0 Fax: +49 (0) 5206 999 999 E-Mail: info@bst.group Internet: www.bst.group This documentation is protected by copyright. The translation as well as reproduction and distribution in any form is forbidden without the approval...
Inverting the Signal of the BTL5 Linear Position Sensor .......... 19 5.4.3 Setting the Stroke Limitation and Servo-Center Position of the Actuator .... 21 5.4.4 Procedure for Changing Parameter Values .............. 21 Index ....................... 23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
These instructions and all other applicable documents are a com- ponent of the product and must be handed over to the operating company of the system. 4/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
Operations using the keys are indicated by the following symbols: Press key ①. ► Press key ① or key ②. ► Press key ① and key ② at the same time. ► ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 5/23...
Document Document Number Installation and commissioning manual MD.541 ekr CON 600, ekr CON 600 net Operating manual MD.542 ekr CON 600, ekr CON 600 net 6/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
Requirements The following requirements must be met in order to operate the BTL5 linear position sensor on the BST ekr CON 600, ekr CON 600 net web guiding controller: Firmware version of the ekr CON 600, ekr CON 600 net controller ■...
5 μm. This is done with high precision and reproducibility with the selected resolution within the measuring range designated as the nominal length. 8/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
Do not install the linear position sensors in the direct vicinity of ► strong electric or magnetic fields. Be sure to maintain the specified distances for installation. ► ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 9/23...
2. Attach the linear position sensor to the base using the cylinder- head screws. Tighten the screws in the mounting clamps with a tightening torque of max. 2 Nm. 10/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
0.1 … 4 mm. The selected distance B must remain constant over the entire measuring length. The center offset C of the magnet must not exceed ± 2 mm. ■ ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 11/23...
► ponds with the details specified on the nameplate of the com- ponents. Select the correct terminals and polarity when connecting the ► power supply. 12/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
BUS OUT BUS IN (socket) (plug) Fig. 5: Contact assignment of the connections (top view of connections on BTL5) Contact Signal CAN-GND +20 … 28 V 0 V (GND) CAN-H CAN-L ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 13/23...
Extension cable or spiral cable 0.5 m / 2 m (168 176) 2 m (131 993) 5 m (131 994) Connecting cable BTL5 (249 662) 10 m (131 995) Fig. 6: Connection example 14/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
The controller is connected to the power supply. ■ All transport locking devices on the guiding device and actuator ■ have been removed. ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 15/23...
S1.7 … S1.9 Setting the baud rate See Setting the Baud Rate, page 17 S1.10 Switching the terminating See Switching On the resistor on/off Terminating Resistor, page 18 16/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
By adding the values that are assigned to the individual DIL switches, baud rates from 1,000 kBaud (value 1) to 50 kBaud (value 7) can be set (see following table). ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 17/23...
CAN bus (see Connection Example, page 14), the internal terminating resistor of the linear position sensor must be switched on using DIL switch S1.10 (S1.10 = ON). 18/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
Parameter Setting Function Parameter Meaning Value Signal inversion deactivated Inverting the position (OFF) BTL5 inverted signal of the linear position sensor Signal inversion activated (ON) ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 19/23...
Page 20
If the sign of the displayed position value does not match the direc- tion of movement of the bar graph display, you must activate the signal inversion for the linear position sensor (BTL5 inverted = 1). 20/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
The setting is made on the ekr CON 600, ekr CON 600 net web guiding controller using the special setup menu for actuators with position feedback.
Page 22
The new parameter value is entered into the editing field. 14. Press the button to save the edited parameter values. The Switch positions service display is displayed. 22/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
Setting the baud rate ........ 17 Setting the device address...... 17 Switching on the terminating resistor ... 18 Technical specifications ........ 7 Type .............. 7 Utilisation............ 7 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 23/23...