Web Guiding System
Installation and
Commissioning Manual
ekr CON 600
ekr CON 600 net
Application with Linear Position Sensor BTL5
MD.672.EN.01
Translation of the Original Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ekr CON 600 and is the answer not in the manual?

Questions and answers

Summary of Contents for BST ekr CON 600

  • Page 1 Web Guiding System Installation and Commissioning Manual ekr CON 600 ekr CON 600 net Application with Linear Position Sensor BTL5 MD.672.EN.01 Translation of the Original Manual...
  • Page 2 BST GmbH Remusweg 1 D-33729 Bielefeld Tel.: +49 (0) 521 400 70 0 Fax: +49 (0) 5206 999 999 E-Mail: info@bst.group Internet: www.bst.group This documentation is protected by copyright. The translation as well as reproduction and distribution in any form is forbidden without the approval...
  • Page 3: Table Of Contents

    Inverting the Signal of the BTL5 Linear Position Sensor .......... 19 5.4.3 Setting the Stroke Limitation and Servo-Center Position of the Actuator .... 21 5.4.4 Procedure for Changing Parameter Values .............. 21 Index .......................  23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 4: About This Document

    These instructions and all other applicable documents are a com- ponent of the product and must be handed over to the operating company of the system. 4/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 5: Meanings Of The Safety Instructions And Symbols

    Operations using the keys are indicated by the following symbols: Press key ①. ► Press key ① or key ②. ► Press key ① and key ② at the same time. ► ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 5/23...
  • Page 6: More Detailed Information

    Document Document Number Installation and commissioning manual MD.541 ekr CON 600, ekr CON 600 net Operating manual MD.542 ekr CON 600, ekr CON 600 net 6/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 7: Design And Function

    Requirements The following requirements must be met in order to operate the BTL5 linear position sensor on the BST ekr CON 600, ekr CON 600 net web guiding controller: Firmware version of the ekr CON 600, ekr CON 600 net controller ■...
  • Page 8: Design

    5 μm. This is done with high precision and reproducibility with the selected resolution within the measuring range designated as the nominal length. 8/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 9: Installation

    Do not install the linear position sensors in the direct vicinity of ► strong electric or magnetic fields. Be sure to maintain the specified distances for installation. ► ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 9/23...
  • Page 10: Installing The Linear Position Sensor

    2. Attach the linear position sensor to the base using the cylinder- head screws. Tighten the screws in the mounting clamps with a tightening torque of max. 2 Nm. 10/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 11: Installing The Magnet

    0.1 … 4 mm. The selected distance B must remain constant over the entire measuring length. The center offset C of the magnet must not exceed ± 2 mm. ■ ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 11/23...
  • Page 12: Electrical Connection

    ► ponds with the details specified on the nameplate of the com- ponents. Select the correct terminals and polarity when connecting the ► power supply. 12/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 13: Connections On The Btl5 Linear Position Sensor

    BUS OUT BUS IN (socket) (plug) Fig. 5: Contact assignment of the connections (top view of connections on BTL5) Contact Signal CAN-GND +20 … 28 V 0 V (GND) CAN-H CAN-L ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 13/23...
  • Page 14: Connection Example

    Extension cable or spiral cable 0.5 m / 2 m (168 176) 2 m (131 993) 5 m (131 994) Connecting cable BTL5 (249 662) 10 m (131 995) Fig. 6: Connection example 14/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 15: Commissioning

    The controller is connected to the power supply. ■ All transport locking devices on the guiding device and actuator ■ have been removed. ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 15/23...
  • Page 16: Settings On The Btl5 Linear Position Sensor

    S1.7 … S1.9 Setting the baud rate See Setting the Baud Rate, page 17 S1.10 Switching the terminating See Switching On the resistor on/off Terminating Resistor, page 18 16/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 17: Setting The Device Address

    By adding the values that are assigned to the individual DIL switches, baud rates from 1,000 kBaud (value 1) to 50 kBaud (value 7) can be set (see following table). ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 17/23...
  • Page 18: Switching On The Terminating Resistor

    CAN bus (see Connection Example, page 14), the internal terminating resistor of the linear position sensor must be switched on using DIL switch S1.10 (S1.10 = ON). 18/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 19: Settings On The Ekr Con 600 (Net) Controller

    Parameter Setting Function Parameter Meaning Value Signal inversion deactivated Inverting the position (OFF) BTL5 inverted signal of the linear position sensor Signal inversion activated (ON) ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 19/23...
  • Page 20 If the sign of the displayed position value does not match the direc- tion of movement of the bar graph display, you must activate the signal inversion for the linear position sensor (BTL5 inverted = 1). 20/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 21: Setting The Stroke Limitation And Servo-Center Position Of The Actuator

    The setting is made on the ekr CON 600, ekr CON 600 net web guiding controller using the special setup menu for actuators with position feedback.
  • Page 22 The new parameter value is entered into the editing field. 14. Press the button to save the edited parameter values. The Switch positions service display is displayed. 22/23 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5...
  • Page 23: Index

    Setting the baud rate ........  17 Setting the device address......  17 Switching on the terminating resistor ...  18 Technical specifications ........  7 Type ..............  7 Utilisation............  7 ekr CON 600, ekr CON 600 net – Application with Linear Position Sensor BTL5 23/23...