Autoconvert preaction valve preaction electric autoconvertdry trim (52 pages)
Summary of Contents for Victaulic FireLock 751 Series
Page 1
Pág: RT-10-SG_MHP-EMT-001 CLIENTE: YACIMIENTO CARBONIFERO RIO TURBIO (YCRT) PROYECTO: CENTRAL TERMOELECTRICA RIO TURBIO 2x120 MWe INGENIERÍA DE SISTEMAS MECÁNICOS Y DE CONTROL HOJAS DE DATOS HOJAS TÉCNICAS DE EQUIPOS 24-02-2011 HOJAS TÉCNICAS DE EQUIPOS S.P.S. S.P.S. S.P.G. FECHA DESCRIPCION AUTOR REVISADO APROBADO RT-10-SG_-MHP-EMT-001_0–HOJAS TÉCNICAS DE EQUIPOS...
Page 2
Se presenta tabla resumen de los principales equipos de extinción por zonas y sus correspondientes hojas técnicas: TIPO DE SPRINKLER/BOQUILLA EDIFICIO/EQUIPO Puesto de control Rociador Boquilla Sala de bombas Húmedo (serie 751) TY3151/V2703 Tanque de gasoil Diluvio (serie 769) Black Start Preacción (serie 769) TY4151/V3401 Bombas de agua de...
The Victaulic Series 751 alarm check valve is made from high strength, low weight ductile iron, and offers easy access to all internal parts. All internal parts are replaceable without having to remove the valve from the installed position.
Page 4
30.01 DIMENSIONS Optional Retard Chamber Typical 4"/100 mm – other sizes may vary. Dimensions Aprx. Wgt. Each Valve Size Inches/mm Lbs./kg Actual Nominal Outside Diameter Diameter E to E Height Width Depth Without With In./mm In./mm Trim Trim GROOVED X GROOVED 1.900 9.00 18.50...
Page 5
4,000 6,000 10,000 20,000 3,000 8,000 FLOW RATE – GPM The chart below expresses the frictional resistance of Victaulic Series 756 Dry Check Valve in equivalent feet of straight pipe. FRICTIONAL RESISTANCE Nominal Size Nominal Size Inches/ Equivalent Length of Pipe...
30.01 MATERIAL SPECIFICATIONS Body: Ductile iron, ASTM A-536 Grade 65-45-12 Clapper: Aluminum bronze UNS-C95500 or UNS-C36000 Shaft: Stainless 17-4 Clapper Seal: EPDM, ASTM D2000 Seat O-Rings: Nitrile Springs: Stainless steel (300 Series) 4 - 6" 1¹⁄₂ - 3 & 8" BILL OF MATERIALS 1 Valve Body Clapper Spring...
Page 7
30.01 PARTS With Vertical Trim Grooved X Grooved SERIES 760 WATER MOTOR ALARM U L C LISTED ³⁄₄ Optional Pressure Switch To Water Motor Alarm or Optional Restrictor Optional Series 752V Retard Vent Kit Pipe to Open Drain To Drain To Drain Flanged ✕...
Page 8
30.01 PARTS With Horizontal Trim Grooved X Grooved SERIES 760 WATER MOTOR ALARM U L C LISTED ³⁄₄ Optional Pressure Switch Optional Series 752V Retard Vent Kit To Drain Pipe to Open Drain Flanged ✕ Grooved To Drain BILL OF MATERIALS 1 Series 751 FireLock Alarm Valve 8 Main System Drain Valve 2 Water Supply Pressure Gauge (0-300 psi)
Page 9
30.01 PARTS Series 751 Trim for Use with Excess Pressure Pump Grooved X Grooved Pressure Switch From Excess Pressure Pump SERIES 760 WATER MOTOR ALARM U L C LISTED ³⁄₄ Normally Normally Open Closed Optional Location for Item 12 To Excess Normally Pressure Pump Closed...
Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
Page 11
769 is available grooved x grooved. Standard grooved dimensions conform to ANSI/AWWA C606. Victaulic Series 769 Preaction valves do NOT require a separate check valve in the preaction system and feature a straight-through valve body design that provides superior flow and low-pressure drop.
Victaulic Series 769 Actuated Valve will act as an Alarm Check Valve. If the valve is actuated by the activation or damage of a sprinkler system sprinkler, water will enter the system and flow from any open sprinklers.
If the pilot sprinkler activates and a system sprinkler does not operate, water will fill the sprinkler system, alarms will be activated and the Victaulic Series 769 Actuated Valve will act as an Alarm Check Valve. If a system sprinkler is damaged or activates and there is no release mechanism detection the low pressure alarm in the system will activate but no water will flow until there is a release detection.
Page 14
Both electric detection devices are wired into an approved control panel in a “cross-zoned” configu- ration. The electric control panel controls a solenoid valve piped to the Victaulic Series 769 Actuated Valve piston. In the event of a fire detection device activation and no pressure loss in the sprinkler system the control panel will not trigger the solenoid valve and the valve will not actuate.
Page 19
1499.1 OPERATION The Victaulic Preaction System utilizes the Series 769 Preaction Valve to control the entry of the water supply into the Preaction System piping and sprinklers. The Series 769 Preaction Valve is con- structed with a clapper having a replaceable rubber face. The clapper makes contact with the valve seat ring which has access holes to the intermediate chamber of the valve.
Page 22
The compressor, low pressure alarms, ball valves, and required trim are included in the air supply system. • Air Compressor (See page 14 for more on the Victaulic Series 7C7 Compressor Package) • Air Maintenance Trim Assembly • Alarm Panels...
Page 24
“on” or “low” pressure setting for the compressor. The “off” or “high” pressure setting should be 18 psi/124 kPa. Victaulic offers the Series 7C7 Compressor package for FireLock NXT devices which is riser-mounted and pre-set for the FireLock NXT pressure requirements as stated above.
Page 33
With Preaction Trim Grooved x Grooved WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044-0031, 610-559-3300.
Victaulic for details. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
Page 55
40.15-SPA PRODUCTOS DE PROTECCIÓN CONTRA INCENDIOS – ROCIADORES AUTOMÁTICOS V34, K8.0 PARA MAYOR INFORMACIÓN, CONSULTE PUBLICACIÓN 10.01 DE VICTAULIC Pulverizador estándar/colgante, vertical y colgante empotrado MODELOS V3401, V3402, V3405 Y V3406 RESPUESTA ESTÁNDAR Y RESPUESTA RÁPIDA Estos rociadores de pulverización estándar Modelo V34 han sido diseñados para producir una gran capacidad de descarga en un patrón hemisférico estándar en aplicaciones comerciales. El diseño incorpora una ampolla de vidrio frágil de alta calidad sensible al calor (respuesta estándar o respuesta rápida) para un funcionamiento rápido y preciso.
Page 56
RANGOS Todas las ampollas de vidrio están homologadas para temperaturas desde -54°C (-65°F) hasta las indicadas en la tabla siguiente. Temperatura – ºC/ºF Clasificación de temperaturas Identificación de piezas Rangos de temperaturas Temperatura ambiente Color de la ampolla de rociadores Victaulic nominales máxima admisible de vidrio Ordinaria Naranja Ordinaria Rojo Intermedia Amarillo Intermedia...
Si precisa copias adicionales de este documento, o tiene alguna duda respecto a la seguridad durante la instalación de este producto, póngase en contacto con la Sede mundial de Victaulic: P.O. Box 31, Easton, Pennsylvania 18044-0031 EE UU, Teléfono: 001-610-559-3300.
Page 60
Los datos indicados son aproximados y pueden variar debido a diferencias en la instalación. 2 En estos gráficos se ilustran las trayectorias aproximadas, los patrones de humedecimiento de suelo y paredes para estos rociadores automáticos específicos Victaulic FireLock. Se ofrecen como información guía para evitar obstrucciones en rociadores y no deben utilizarse como reglas de espaciado mínimas de rociadores para su instalación. Consulte el folleto de la Asociación Nacional de Protección contra Incendios (NFPA) apropiado o con las autoridades...
Page 61
MODELOS V3401, V3402, V3405 Y V3406 RESPUESTA ESTÁNDAR Y RESPUESTA RÁPIDA GARANTÍA Para más información, consulte la sección de garantías de la Lista de Precios o contacte con Victaulic. NOTA Este producto debe ser fabricado por Victaulic o según sus especificaciones. Todos los productos deben instalarse de acuerdo a las instrucciones de instalación y ensamblado de Victaulic. Victaulic se reserva el derecho a cambiar las especificaciones, diseño y equipamiento...
Page 63
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Series TY-B — 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage cable approval agencies, the testing is General not representative of all possible cor- rosive atmospheres.
Page 64
Page 2 of 8 TFP151 ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING NOMINAL 1/2" DEFLECTOR SURFACE MAKE-IN 2-3/16" 2-1/4" (55,6 mm) (57,2 mm) WRENCH 1-9/16" FLATS (39,7 mm) CROSS DEFLECTOR PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector Temperature rating is indicated on deflector or adjacent to 2 - Button...
TFP151 Page 7 of 8 sprinkler. Readjust the position of the The Series TY-B Recessed Pendent and after installation. Sprinklers dam- sprinkler fitting to suit. Sprinklers must be installed in ac- aged by dropping, striking, wrench cordance with the following instruc- twist/slippage, or the like, must be re- The Series TY-B Pendent and Up- tions.
Page 79
Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 Type D3 Protectospray ® Directional Spray Nozzles, Open, TFP802 Appendix Material General Appendix Description Material Type D3 Protectospray Nozzles are As fixed directional spray nozzles, the open (non-automatic) directional Type D3 Protectospray Nozzles can spray nozzles and they are designed be installed at any fixed angle of 0 for use in water spray fixed systems for...
Extintor de Polvo Bajo Presión CARACTERISTICAS PARA FUEGOS CLASE CAPACIDAD Fabricados con la más alta tecnología con materiales duraderos y de gran calidad. Sencillo funcionamiento y mantenimiento. Recipiente de chapa de acero al carbono laminada en frío de primera calidad. Válvula de latón forjado rosca M30, con palancas de acero al carbono pintadas con pintura en polvo termoconvertible.
Page 93
Extintor a base de Dióxido de Carbono (CO2) CARACTERISTICAS PARA FUEGOS CLASE CAPACIDAD Fabricados con la más alta tecnología con materiales duraderos y de gran calidad. Sencillo funcionamiento y mantenimiento. Recargables. Agente extintor limpio, no corrosivo y no conductor . Recipiente de caño de acero sin costura conformado en caliente sin aporte de soldadura.
Page 94
Matafuego (Extintor) Rodante a base de Polvo químico ABC de 25Kg. CARACTERISTICAS PARA FUEGOS CLASE CAPACIDAD Fabricados con la más alta tecnología con materiales duraderos y de gran calidad. Sencillo funcionamiento y mantenimiento. Practicidad de uso, pudiendo ser utilizado por una sola persona. Recipiente de chapa de acero al carbono de primera calidad.
Need help?
Do you have a question about the FireLock 751 Series and is the answer not in the manual?
Questions and answers