■ Introduction
This is the instruction manual for the Shim-pack NovaCore C18-
HB. The Shim-pack NovaCore C18-HB is a core-shell column that
utilizes an organic silica hybrid . To ensure stable and long-term
use of the Shim-pack NovaCore C18-HB, which has excellent
column performance, please read this instruction manual
carefully and use it correctly.
■ Operating Precautions
Please check for any abnormalities in the appearance and
packaging box of the column.
Verify that there are no errors in the name of the packing
material, particle size, column size, etc., by checking the
labels attached to the packaging box and the column.
The inspection report includes the column lot number,
column serial number, and chromatographic test conditions.
Please keep the report for future reference.
The number of theoretical plate stated in the inspection
report is for quality checks at the time of shipment and does
not indicate the performance (specifications) of the column.
■ Column Performance
The Shim-pack NovaCore C18-HB undergoes rigorous QC testing
to ensure quality and stability. The shipping solvent is
Acetonitrile / Water = 45 : 55 (v : v). Refer to the table below for
the specification of the Shim-pack NovaCore C18-HB columns.
Item
Functional Group
Pore Size
Surface Area
Carbon Content
Endcapping
Column hardware
Usable pH range
Common temperature
Maximum temperature
* The upper temperature limit is 60°C, but using it at conditions where the pH of
mobile phase exceeds 8 at 60°C will accelerate the degradation rate of the column.
High Performance Packed Column for HPLC
Shim-pack NovaCore C18-HB [Reversed phase column]
取 扱 説 明 書
INSTRUCTION MANUAL
Specification
Octadecylsilyl (ODS) group
10 nm
200 m
/g
2
11%
Stainless (SUS)
1-12
20 - 40°C
60°C*
NOTE
Near the pH limit of use, please use a mobile phase containing at
least 10% organic solvent. At the pH limit, column lifetime may be
shortened depending on conditions such as temperature and mobile
phase composition. Additionally, continuing to use the column at the
maximum temperature limit may also reduce its lifetime.
■ Column Installation
The flow direction of the column is indicated by an arrow on
the column label (→). When installing the column, ensure
that the flow direction arrow matches the mobile phase flow
direction.
Use PEEK or SUS tubes with an inner diameter of 0.25 – 0.3
mm (UHPLC: 0.1 – 0.2 mm) and an outer diameter of 1.6 mm.
However, do not use PEEK tubes when working with
fluorinated organic solvents such as tetrahydrofuran (THF),
chloroform, concentrated sulfuric acid, concentrated nitric
acid,
dichloroacetic
acid,
dimethyl sulfoxide (DMSO), and hexafluoroisopropanol
(HFIP).
The 1.7 μm particle size column produces higher
backpressure than the 5 μm or 2.6 μm particle size columns.
Please be aware of the maximum pressure of the HPLC
system and connect the appropriate tubes. Generally,
UHPLC systems that have a maximum pressure above 60
MPa are appropriate for 1.7 µm columns.
Use the shortest possible tubes connection from the injector
to the column to minimize peak broadening.
Use male nuts or fittings for connecting the column. Be
careful to avoid creating any unnecessary gaps during the
connection. For information on column connections, please
also refer to the system guide and the operating manual of
the LC system.
Male nuts or fittings can be obtained with the following
product names and part numbers (P/N).
Item Name
P/N
Male Nut, PEEK
228-18565-84
Male Nut Fitting Kit
228-45717-01
UHPLC Fitting 2 S
228-56867-41
NOTE
Particulates or air in the system flow line may deteriorate the
column. Before connecting the column, be sure to filter all solvents
and flush the flow line up to the column with mobile phase.
ERAD-0001-9087A
acetone,
dichloromethane,
Pressure
Remarks
Limit
5 pcs
20 MPa
2 pcs
35 MPa
1 pc
130 MPa

Advertisement

loading
Need help?

Need help?

Do you have a question about the CoreFocus Shim-pack NovaCore C18-HB and is the answer not in the manual?

Questions and answers

Summary of Contents for Shimadzu CoreFocus Shim-pack NovaCore C18-HB

  • Page 1 日本語取扱説明書はP.4以降をご参照ください。 ERAD-0001-9087A High Performance Packed Column for HPLC Shim-pack NovaCore C18-HB [Reversed phase column] 取 扱 説 明 書 INSTRUCTION MANUAL ■ Introduction NOTE This is the instruction manual for the Shim-pack NovaCore C18- Near the pH limit of use, please use a mobile phase containing at least 10% organic solvent.
  • Page 2 ERAD-0001-9087A • If peaks are tailing more on the early eluting compounds NOTE When switching from aqueous solvents to non-aqueous solvents, it is than later eluting compounds, it’s possible that there is recommended to flush with an intermediate polarity solvent, such as dead volume.
  • Page 3: Disposal Precautions

    60% acetonitrile aqueous solution. ・CoreFocus and Shim-pack are trademarks of Shimadzu Corporation or its affiliated companies in Japan and/or other countries. ・The contents of this instruction sheet are subject to change without notice.
  • Page 4 ERAD-0001-9087A 高速液体クロマトグラフ用 高性能充てんカラム Shim-pack NovaCore C18-HB [逆相カラム] 取 扱 説 明 書 取 扱 説 明 書 はじめに 注 記 本取扱説明書の対象はShim-pack NovaCore C18-HBです。 仕様pH上限付近では 10% 以上の有機溶媒を含む移動相を使用し てください。仕様pH上限付近では、温度や移動相組成などの条 Shim-pack NovaCore C18-HBは有機シリカハイブリッド基材 件によってカラム寿命が短くなる場合があります。 また、仕様 を採用したコアシェルカラムです。優れたカラム性能を持 上限温度で使用を続けると、カラムの寿命が短くなる可能性が つShim-pack NovaCore C18-HBを安定して長期間使用するた あります。 めに、本取扱説明書をよくお読みの上、正しく使用してく カラムの取り付け ださい。...
  • Page 5 ERAD-0001-9087A  移動相溶媒の選択 • 溶出の早いピークがテーリングする場合、その原因と • 移動相には水系から非水系溶媒まで使用できますが、 してデッドボリュームが考えられます。カラムジョイ 極性が極端に異なる溶媒間の置換を繰り返すとカラム ント部分に接続配管が奥まで挿入されているか確認し 性能が低下する恐れがあります。使用可能な一般的有 てください。目安としてフェルールの先端から配管が5 機溶媒は、アセトニトリル、メタノール、テトラヒド mm程度出た状態で締結し、取り外したときにフェルー ロフラン (THF) などです。ただし、THF 使用時は流路に ルの先端から配管が2~3 mm出た状態であれば正常で 使用する配管などの材質の耐溶媒性にご注意ください。 す。 • インジェクター - カラム - 検出器間の配管は、使用する 注 記 カラムの内径やその分析系に適した内径、長さのもの 互いに混合しない水系溶媒から非水系溶媒への変更は、両方の を選択してください。特にセミミクロカラムなどを用 溶媒に混和するイソプロパノールやジオキサンなどの中間極性 溶媒を通常カラム容量 の 10 倍以上 (150 × 4.6 mm I.D. ならば約 いて低流量で分析する場合には配管の影響が大きくな...
  • Page 6 きな物質を洗浄してください。有機溶媒は 100% まで使 用できます。特に脂溶性の高い成分が吸着している場合、 THF を添加すると効果的な場合があります。 • 移動相に緩衝液や塩を含む場合やイオンペア剤などを含 む移動相を使用した場合は、これらを含まない水/有機 溶媒混合液 (移動相と同等比率) に一旦置換した後、上記 と同様に洗浄してください。50 mmol/L程度の緩衝液や 塩であれば、60% アセトニトリル水溶液に直接置換でき ます。この時、塩が析出しないよう置換手順にはご注意 下さい。 • pH限界付近で使用後、水のみで洗浄するとカラム劣化を 引き起こす場合があります。前述の水/有機溶媒混合液 本社 や 60% アセトニトリル水溶液で洗浄してください。 住所:東京都台東区浅草橋5-20-8 CSタワー5F • タンパク質や多糖類などの高分子化合物がカラムに吸着 TEL:03-5835-0120 した場合、洗浄により除去することは一般的に困難です。 関西支店 これらを含む試料や夾雑物の多い試料の場合、あらかじ 住所:大阪市北区豊崎3-1-22 淀川6番館6F め前処理を行うことを推奨します。 TEL:06-7220-9086 https://solutions.shimadzu.co.jp/glc/ gsupport@glc.shimadzu.co.jp ・CoreFocus、Shim-pack は株式会社島津製作所またはその関係会社の日本およびその他の国における商標です。 ・外観および仕様は改良のため、予告なく変更することがありますのでご了承ください。...