39. Appendix III – DDC/CI support at HDMI & Display port 40. Appendix IV - Mapping definition 41. Appendix V – DV remote control unit work for SVX-4096-120v2 42. Appendix VI – Light Sensor Function work for SVX-4096-120v2 43. Warranty, Caution & Limitation of Liability, Trademarks 44.
Page 2
Introduction Designed for LCD monitor and other flat panel display applications, the SVX-4096-120v2 is a feature rich interface controller for : TFT (active matrix) LCD panels of 4096x2160 resolutions in 60Hz or 120Hz with V-by-One/eDP interface. Support true 10 bits panel ...
ASSEMBLY NOTES This controller is designed for monitor and custom display projects using 4096x2160 resolution with V-by-One interface, eDP interface or LVDS TFT panels. The following provides some guidelines for installation and preparation of a finished display solution. Preparation: Before proceeding it is important to familiarize yourself with the parts making up the system and the various connectors, mounting holes and general layout of the controller.
Page 5
Power output: Note the controller has an overall 3Amp current limit and the current available from the auxiliary power output will be dependent on the power input and other system requirements. Power Safety: Note that although only 12V / 24VDC is required as ‘power-in’ a backlight inverter for panel backlighting produces significantly higher voltages (the inverter does not connect to the ground plane).
Power supply & Controller: Plug the DC 12V/24V power in to the connector PP2 or PP5. You can consider to use DigitalView mating power cable P/N 426013710-3, 1000mm for PP5 connection. 10. External panel power input : Plug power cable : P/N 426013710-3 for external panel power input (3.3 (max 7A) / 5V (max.
Page 7
LCD DISPLAY SYSTEM SETTINGS NOTE: By way of explanation the following refers to a set of sample buttons that may be obtained as an option. In addition to power on/off and connection for backlight brightness the controller provides an On Screen Display of certain functions which are controlled by 8 momentary type buttons (digital type) or 5 button OSD switch mount board: Controls Digital type...
Page 8
OSD Functions Information Input signal information reported : Input port / Resolution / H.Total / V.Total / H.Freq / V.Freq / Data CLK Picture Increase/decrease Black level. Black Level Press – or + (- +) 0~100 [Default : 50] Increase/decrease Contrast level. Contrast Press –...
Page 9
Top Left (Default) Bottom Left Position Bottom Right Top Right User Blend Level Adjust the Blend level, total: 17 steps Press – or + (- +) 0~100 [Default : 100] Auto Source On : Enable the Auto source seek function [Default] Off : Disable the Auto source seek function Seek Select the Displayport 1 be the input video signal...
Page 10
HotKey Settings Hotkey 1 : Volume / Black Level / Contrast / Inputs / Aspect / PIP Size / PIP On_Off / Saturation / Hue / Brightness / Rotate / No function Hotkey 2 : Volume / Black Level / Contrast / Inputs / Aspect / PIP Size / PIP On_Off / Saturation / Hue / Brightness / Rotate / No function System Settings...
CONNECTORS, PINOUTS & JUMPERS The various connectors are: Summary: Connectors Purpose Description RS-232 serial control JST 6-way, B6B-XH-A (Matching type : XHP-6) CN11 SPDIF Audio output JST B2B-ZR (Matching type : ZHR-2) (Matching extend cable P/N 426007400-3) CN14 Audio line out JST B4B-PH-K compatible (Matching type : PHR-4) (Use audio cable P/N 426451800-3 to connect with audio add-on bard...
Page 12
DC power Molex 2 pin 0.156” pitch Power input (alternative) External panel power input Molex 43045-0400 compatible (Matching connector type : Molex 43025-0400 compatible) (Matching power cable : P/N 426013710-3) 12V/24VDC input power Molex 43045-0400 compatible (Matching connector type : Molex 43025-0400 compatible) (Matching power cable : P/N 426013710-3) Panel timing selection 8-way DIP Switch...
Page 13
Summary: Jumpers setting Purpose Note Panel power voltage select See panel voltage setting table 1 CAUTION: Incorrect setting can damage panel Panel power voltage select See panel voltage setting table 1 CAUTION: Incorrect setting will cause panel damage Panel power voltage select See panel voltage setting table 1 CAUTION: Incorrect setting will cause panel damage...
Page 14
Table 1 : Panel voltage setting table (JA3, JA7, JA8 and JA9) : Input voltage via PP2/PP5 Panel Voltage Jumper on board 3.3V 3V3 closed 1-2 & 3-4 OPEN OPEN 12VDC 5V closed 1-2 & 3-4 OPEN OPEN OPEN OPEN 1-2 &...
Page 15
Input voltage via Input voltage via PP2 / PP5 Panel Voltage Jumper on board 3.3V 3.3V OPEN OPEN OPEN 1-2 & 3-4 OPEN OPEN OPEN 1-2 & 3-4 OPEN OPEN OPEN 1-2 & 3-4 12V / 24VDC OPEN OPEN OPEN 1-2 &...
Page 16
Table 2 : Panel Output power pin selection table (JP11 and JP12): Output power pin selection on J7_OUT JP11 JP12 Jumper on board Pin-44 to Pin-51 1-2 CLOSE 1-2 CLOSE (Pin-1 to Pin-8)* Pin-48 to Pin-51 1-2 CLOSE 1-2 OPEN (Pin-1 to Pin-4)* Pin-44 to Pin-47 1-2 OPEN...
Page 18
CN1 –Reserved for Engineering use purpose: JST B6B-XH-A (Matching type : XHP-6) SYMBOL DESCRIPTION No connection No connection RS-232 Tx data Ground RS-232 Rx data CN2 – Alternate DVI connector: JST BM20B-SRDS (Matching type : SHDR-20V-S-B) SYMBOL DESCRIPTION Digital Ground Digital Ground TMDS Clock+ /RXC...
Page 19
CN8 – RS-232 serial control: JST B6B-XH-A (Matching type : XHP-6) SYMBOL DESCRIPTION EXT_SCL Reserved EXT_SDA Reserved RS-232 Tx data Ground RS-232 Rx data CN10 - Fan and backlight power monitoring connector : Hirose DF13-9P-1.25 DSA (Matching type : DF13-9S-1.25C) SYMBOL DESCRIPTION Ground...
Page 20
CNA1 - Auxiliary power output: JST B4B-XH-A (Matching type : XHP-4) SYMBOL DESCRIPTION AUX 12V / 24V +12V / +24V DC Ground Ground AUX 5V +5V DC, 500mA max CNB1 – Backlight inverter connector: JST B5B-XH-A (Matching type : XHP-5) SYMBOL DESCRIPTION Ground...
Page 21
(35) VB1_TX2P V-by-One HS Data Lane 2 (34) VB1_TX2N V-by-One HS Data Lane 2 (33) Ground (32) VB1_TX1P V-by-One HS Data Lane 1 (31) VB1_TX1N V-by-One HS Data Lane 1 (30) Ground (29) VB1_TX0P V-by-One HS Data Lane 0 (28) VB1_TX0N V-by-One HS Data Lane 0 (27)
Page 22
Ground VB1_TX9P V-By-One Lane 9 VB1_TX9N V-By-One Lane 9 Ground VB1_TX8P V-By-One Lane 8 VB1_TX8N V-By-One Lane 8 Ground LED1 – Status LED connector: 3-pin header DESCRIPTION Green LED pin (anode) LED pin common (cathode) Red LED pin (anode) PP2 – Alternate 12V/24VDC input power: Molex 2 pin 0.156" pitch DESCRIPTION +12VDC / 24VDC in Ground...
Ready-made 3D Pro-E (SLDPRT) drawing files - Save time and effort for your system volumetric analysis design. Includes jpg file previews. Please go to download at http://www.digitalview.com/products/svx-4096-120v2-lcd-controller The maximum thickness of the controller is 18.93mm with or without video add-on board (measured from bottom of PCB to top of components, including any underside components &...
APPLICATION NOTES USING THE CONTROLLER WITHOUT BUTTONS ATTACHED This is very straightforward: Firstly setup the controller/display system with the buttons. With controls attached and display system active make any settings for color, tint and image position as required then switch everything off. ...
Page 25
Design Guideline for making VR circuitry : Signal description / Notes : 1) R1 : 470ohm on board 2) RPOT is an external potentiometer (in-line dip style) that can be plugged directly into CNC1 pins 3,4,5. RPOT must be supplied / installed by user. 3) BVR_B : Voltage tapped from “top”...
TROUBLESHOOTING General A general guide to troubleshooting a flat panel display system it is worth considering the system as separate elements, such as: Controller (jumpers, PC settings) Panel (controller, cabling, connection, panel, PC settings) Backlight (inverter, cabling, backlight tubes) ...
SPECIFICATIONS Panel compatibility Compatible with 4096x2160 resolutions of TFT LCD panels with V-by-One panel interface. A specified BIOS and some factory adjustment is required for individual panel timings. No. of colors Up to 3 x 10 bit providing 1.06 billion colors. Panel power DC 3.3V, 5V, 10V, 12V, 18V Panel signal...
Page 32
1. Commands to implement switch mount control buttons Function Command Description Remark Menu button 0xf7 Menu button pressed Button equivalent Select-down button 0xfa Select-down button pressed Button equivalent Select-up button 0xfb Select-up button pressed Button equivalent Right/+ button 0xfc Right/+ button pressed Button equivalent Left/- button 0xfd...
Page 33
“?” Query “0” – 1:1 Aspect Ratio 0x8c, Set video aspect ratio= “0” | “1” | “9” | “A” | “1” – fill screen (Default) Value “F” “9” – 4:3 Reset “r” | “R” | “A” – 16:9 Query “?” “F”...
Page 34
“?” “3” – contrast Query “4” – color saturation “5” – input source (P1 source) “9” – PIP size “B” – No hot key function (Default) “D” – PIP Swap “E” – Aspect ratio “G” – Hue “H” – Backlight level ''L'' - Sharpness ''M'' - Display mode (select 1P, 2P PIP, 2P PBP or 4P)
Page 35
0xa7, “c” P3 source select Select P3 video source = P3 is upper right window in 4P mode nn | Video source value “r” | “R” | Reset “nn” = “?” Query “0x50,0x31” D0: DP1 “0x50,0x32” D0: DP2 “0x48,0x31” D1: HDMI1 “0x48,0x32”...
Page 36
“nnnc” = vertical frequency Video vertical sync 0xba Vertical sync frequency (in units of frequency Hz) in 3 digit hex number and 1 nnn = 3 digit hex c= “i” (interlace) or “p” (progressive) char “0” – OSD turned off OSD status enquiry 0xbb Status of OSD...
Page 37
“0xee”, “0x62” “0”- Unlock (Default) OSD switch mount “0” |”1” “1”- Lock, no response to OSD switch Lock Unlock / Lock ”?” Query mount keys “0xee”, “0x6B”, Default Power Default power state after supplying “0x50” power to controller “0”| “0” - default power off “1”| “1”...
Page 38
E = Engineering Sample YY= Version Number ZZ= Customer Number 0xcb, “1” “nnnnn” = PCBA number Query PCBA Read PCBA number SVX-4096-120v2= “41786” number 0xcb, “3” “nn” = Revision number AA in firmware Query Revision Read Revision Number version no. “ VV.YY.ZZ.AA”...
n = 1-byte ascii-coded hex number, e.g., parameter value of 0x1 is represented by “1” (0x31). mn or nn = 2-byte ascii-coded hex number, e.g., parameter value of 0x1e is represented by “1”, “e” | “E” (0x31, 0x6e|0x4e). The RS-232 command strings sent in one time can support up to 380 bytes via CN8 port n = 1-byte ascii-coded hex number, e.g., parameter value of 0x1 is represented by “1”...
Appendix V – DV remote control unit work for SVX-4096-120v2 P/N 5590001xx-3 : DigitalView remote control unit (without DV logo silk screen printing) BUTTON FUNCTION POWER BUTTON Soft power ON/OFF button. 1. In OSD menu, pressing "SEL UP" button to move previous level of selection.
Use of the light sensor board P/N 416021310/416021330-3 and light sensor cable P/N 426305900- 3 connect to the SVX-4096-120v2 via CN6 connector or use the light sensor cable P/N 426321940- 3 as shown below : Digital View provides a user-friendly software program (TCP-IP Serial Utility V1.18 or later revision)
Digital View Inc. 18440 Technology Drive Building 130 Morgan Hill, California, 95037 Tel: (1) 408-782 7773 Fax: (1) 408-782 7883 Sales: ussales@digitalview.com EUROPE Digital View Ltd. The Lake House Knebworth Park Herts, SG3 6PY Tel: +44-(0)20-7631-2150 Fax: Fax: +44-(0)20-7631-2156 Sales: uksales@digitalview.com...
Need help?
Do you have a question about the SVX-4096-120v2 and is the answer not in the manual?
Questions and answers