Midea COMPACT Series, HS-164LN, UR-BC126CM-ST Manual
Transport
Handling
- Protect the refrigerator in moving it, Same as shown in photo below, please move it by handcart with cushion
![Midea - COMPACT Series - Transporting the product Transporting the product]()
- Remove all packing materials and bottom cushion, the move into house for placement
- After moving it to appropriate location, wait for 2 hours before power on.
Installation and commissioning
Door Disassembly and Assembly
The refrigerator door needs to be dismantled if it cannot enter the room in the whole.
Installation location
![]()
Installation location
Location that is easy for ventilation shall be chosen to facilitate heat dissipation, enhance its performance and reduce the energy consumption.
Leveling of the unit
![Midea - COMPACT Series - Leveling of the unit Leveling of the unit]()
Leveling of the refrigerator
If the refrigerator cannot be placed steadily, adjust the footing to level it.
Left or right open door reversal
Door reversal | None |
Dismantle the upper hinge cover, screws and upper hinge. and remove the plastic screw hole caps from the other side. | ![Midea - COMPACT Series - Left or right open door reversal - Step 1 Left or right open door reversal - Step 1]() |
Dismantle the door and the bottom hinge assembly and adjustable foot, then assemble the bottom hinge assembly and adjustable foot on other side. | ![Midea - COMPACT Series - Left or right open door reversal - Step 2 Left or right open door reversal - Step 2]() |
Dismantle the stopper under the door, then assemble the stopper on the other side. | ![]() |
Put the door on bottom hinge and assemble the upper hinge, upper hinge cover and plastic screw hole caps successively. | ![]() |
Product configuration and dimension
Main parts and their names
![Midea - COMPACT Series - Main parts and their names Main parts and their names]() (The picture is only for reference, and specific appearance and configuration are subject to the real product) |
Freezer chamber | Refrigerator chamber |
None | - Temperature control knob
- Glass shelf
- Fruits and vegetables box
- Steel column strip
- Zip-top can steel bar
|
External dimension
![Midea - COMPACT Series - External dimension External dimension]()
(The picture is only for reference)
Description | Code | Size (mm) |
Height to Top of Case | A | 860 |
Width | B | 495 |
Depth w/Cabinet | C c | 470 |
Depth w/Door | D | 540 |
Depth w/Handle | E | 540 |
Depth (Door open 90 deg. w) | F | 994 |
Width (Door open 135 deg. w) | G | 849 |
Depth (Door open 135 deg. w) | H | 880 |
Location of S/N
![Midea - COMPACT Series - Location of S/N Location of S/N]()
Some products also have S/N on the lower part of the right side of the Cabinet.
Product specification
Electrical parameters
Applicable Models | HS-164LN |
Product Name | UR-BC126CM-ST |
Product Code | 22031010003942 |
Item | Specification |
Refrigerant | R600a |
Compressor | FZ40C1J-USCL2(MD#) |
Starter(PTC) | QP2-4R7 |
Overload protector(OLP) | DRB18T61A1 |
Integrate PTC+OLP | / |
Variable frequency driver board | None |
Capacitor | None |
Power filter | None |
Winding resistance of compressor wiring terminal | Rmc: 13.7±7%Ω Rsc: 10.79±7%Ω Rms=Rmc+Rsc |
Winding resistance picture | ![]() |
The input power of compressor | 48.5W |
Lights inside the refrigerator |
Lights inside the refrigerating chamber | 15W |
Switch of the refrigerator door | sector |
Cooling temperature setting range
Compartment | The highest (°C) | Lowest (°C) |
Freezing | / | / |
Refrigerating | 10 | 0 |
Circuit diagram
![Midea - COMPACT Series - Circuit diagram Circuit diagram]()
Refrigerating piping system and circulating route of cooling air
![Midea - COMPACT Series - Refrigerating piping system Refrigerating piping system]()
- Compressor
- Condenser
- Dry filter
- Capillary tube
- Evaporator
- Suction tube
Dismantling of parts
Parts on the door
![]()
Door seal
It's more convenient to pull out from the corner.
Take the door seal ① out of door liner;
When reloading, the door must be installed into the tank, carefully pressed flat, and check whether there is a gap between the door seal and the box body.
![]()
Guardrail
Grab the Guardrail and squeeze it sideways
Pull out and remove from the refrigerator
Parts inside the unit
![]()
Shelf assembly of refrigerator
Used to place vegetables, fruits and other items.
Lift up the division plate with a proper force and pull it out towards yourself;
![]()
Freezer Drawer
Light system
Light
The light at the right of refrigerator chamber.
- Remove the light cover
![]()
- Loosen the thermostat knob and fastening screw, and remove the thermostat box assembly
![]()
- Remove the connector
- Remove the light
![]()
Light switch
There is a light switch on the side wall of the refrigerating chamber.
Loosen the hook with small normal screwdriver and pull out the switch until the wire connector reveals.
Compressor case
Rear cover and compressor
Rear cover and compressor case | None |
Compressor and the cooling system pipe
- Cut off the power, remove the goods in the refrigerator. with the tape to make the door fixed firmly and prevent the door dropping when the refrigerator dumping.
| ![]() |
- Slowly tilt the refrigerator forward, relying on the wall or a solid enough object, leaving space to facilitate the the operation. For safety, it should be carried by someone to prevent its falling.
| ![Midea - COMPACT Series - Dismantling Compressor and cooling pipe - Step 1 Dismantling Compressor and cooling pipe - Step 1]() |
- Cut off the compressor pipeline.
Cut off the process pipeline. Cut off the low-pressure muffler Cut off the high-pressure exhaust pipe. | ![Midea - COMPACT Series - Dismantling Compressor and cooling pipe - Step 2 Dismantling Compressor and cooling pipe - Step 2]() |
- Remove the screws(for some models)
- Two screws outside
- One screw inside
| ![]() |
- Remove the metal clamp(for some models)
- Disassembly the metal clamp that is fix the electric appliance shield
| ![]() |
- Remove the clipping strip
Slowly pull it out | ![]() |
- Remove the protective cover
- Pry the protective cover slowly from the upper part,
- Pull it out and remove it.
| ![]() |
- Remove the starter and protector
Unplug the starter and protector (you can use a screwdriver to pry it slowly) | ![]() |
- Loosen the screw of the compressor bottom plate, remove the floor together with the compressor from the box
| ![]() |
- Use the wrench to remove the bolts by steps
, replace the compressor and reverse process can complete installation. | ![]() |
- Use Pipe cutter cut off the condenser tube
, then Shear off capillary by the capillary tube scissors. | ![]() |
- Replace the compressor and welding the compressor pipeline
Welding the process pipeline. Welding the low-pressure muffler. Welding the high-pressure exhaust pipe. | ![Midea - COMPACT Series - Dismantling Compressor and cooling pipe - Step 3 Dismantling Compressor and cooling pipe - Step 3]() |
- Replace the filter, Cu-Fe tubes welding
used Ag welding rod, Cu-Cu tubes welding used Cu welding rod | ![]() |
- Vacuum system, The degree of vacuum below 6Pa.
| ![Midea - COMPACT Series - Dismantling Compressor and cooling pipe - Step 4 Dismantling Compressor and cooling pipe - Step 4]() |
- Perfusion refrigerant.
| ![Midea - COMPACT Series - Dismantling Compressor and cooling pipe - Step 5 Dismantling Compressor and cooling pipe - Step 5]() |
- Use the vise grip pliers clamp the middle of the process pipe, then seal welding process tube
. | ![Midea - COMPACT Series - Dismantling Compressor and cooling pipe - Step 5 Dismantling Compressor and cooling pipe - Step 5]() |
Piping system in the compressor case
![Midea - COMPACT Series - Compressor case - Piping system in compressor case Compressor case - Piping system in compressor case]()
- Dry filter
- Suction transition tube
- Compressor
- Right condenser
Drain tray
![Midea - COMPACT Series - Compressor case - Drain tray Compressor case - Drain tray]()
Temperature sensing system
- Remove the nail on the thermostat box assembly. Remove the screws of the fixed temperature control box with a screwdriver.
| ![]() |
- Pull out the knod, remove the socket the terminal, replace the thermostat
| ![]() |
Function and operation
Operation panel
![Midea - COMPACT Series - Using the Operation panel Using the Operation panel]()
Direct cooling mechanical refrigerator, through the thermostat knob to adjust the stalls.
Temperature setting
Turn the temperature control knob to, the internal temperature of the refrigerator becomes lower.
Turn the temperature control knob to, the internal temperature of the refrigerator becomes higher.
Recommended: " "
Open door alarm
(None)
Compressor on and off Control specifications
- When one of the following conditions is met, the compressor stops:
- Tr ≤ Trt;
- When all the following conditions are met, the compressor starts up:
- Tr ≥Trk;
★ When 1. and 2. are not satisfied, the compressor maintains the original state
Troubleshooting Method
Not cooling
![Midea - COMPACT Series - Troubleshooting Method - Not cooling Troubleshooting Method - Not cooling]()
![]()
PTC: 16~50 Ω
Rmc: 10~20 Ω
Rsc: 30~50 Ω
Rms=Rmc+Rsc
Common phenomenon of no cooling:
- The connector has a leak or the terminals are loose.
- Defective protector or starter.
- The connector is reversed, the timer is connected to the wrong line, or the timer is not reset.
- The leakage of the refrigeration system, welding plugs, the capillary depth of the dryer is not enough lead to solder plug.
No working of compressor
![Midea - COMPACT Series - Troubleshooting Method - No working of compressor Troubleshooting Method - No working of compressor]()
Thermostat malfunction/Undercooling
![Midea - COMPACT Series - Troubleshooting Method - Thermostat malfunction Troubleshooting Method - Thermostat malfunction]()
Inside frosting/no defrosting
![Midea - COMPACT Series - Inside frosting/no defrosting - Troubleshooting Inside frosting/no defrosting - Troubleshooting]()
Inside frosting, no defrosting-Maintenance guidelines
![Midea - COMPACT Series - Maintenance in case of Inside frosting - Part 1 Maintenance in case of Inside frosting - Part 1]()
![Midea - COMPACT Series - Maintenance in case of Inside frosting - Part 2 Maintenance in case of Inside frosting - Part 2]()
Light is not on
![Midea - COMPACT Series - Troubleshooting Method - Light is not on Troubleshooting Method - Light is not on]()
Noise
![Midea - COMPACT Series - Troubleshooting Method - Noise Troubleshooting Method - Noise]()
See this section in the TSP.
Entry Guidelines (TSP System)
- Where
Chrome
https://tsp.midea.com
- How
- Midea user: Same as your MIP account & password.
- Overseas customer:
Account: Generated by TSP (provided by administrator).
Each customer have a code in Midea Group, G/E + seven numbers.
If you buy different categories from Midea group, you can see a// the product information account.
Password: abcd1234 (please revise after login in).
If the input error more than 5 times, account wi// be locked, need the administrator to unlock.
Admin team:
REF:Jamie Liu(liujc5@midea.com)
IT: Martin He(dingding.he@midea.com)
Safety Warning Code
![burn hazard]()
![]()
![burn hazard]()
Important Safety Notice
There are special components used in this equipment which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Diagrams, Exploded Views and Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer's specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacturer.
![]()
Important Safety Notice
The Maintenance Manual is only for the use of maintenance personnel with certain experience and background in electrical, electronic and mechanical field.
Any attempt to repair main devices may lead to personal injury and property loss.
Manufacturers or distributors are not responsible for the content of the Manual and interpretation thereof.
Warning for operation safety
Important Safety Instructions
![]()
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within your freezer.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying your freezer.
![]()
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this appliance near water.
- Clean only with a damp cloth.
- Do not block any ventilation openings.
- Install in accordance with the manufacturer's instructions.
- Do not install near any heat sources, such as radiators, heat registers, stoves, or other apparatus that produce heat.
- Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
- Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the appliance.
- Do not attempt to modify or extend the power cord of this appliance.
- Unplug this appliance during lightning storms or when it will not be used for long periods of time.
- Make sure that the available AC power matches the voltage requirements of this appliance.
CONNECTING ELECTRICITY
![burn hazard]()
![]()
![burn hazard]()
Electrical Shock Hazard.
Plug into a grounded 3-prong outlet. Do not remove the ground prong. Do not use an adapter.
Failure to follow these instructions can result in death, fire, or electrical shock.
![burn hazard]()
![]()
![burn hazard]()
Electric Shock Hazard
Failure to follow these instructions can result in electric shock, fire, or death.
![]()
Keep ventilation openings, in both the freezer and the built-in structure, clear of obstruction. ![]()
Do not touch the interior of the freezer with wet hands. This could result in frost bite. ![]()
Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer. ![]()
Do not damage the refrigerant circuit. ![]()
Do not damage the refrigerant tubing when handling, moving, or using the freezer. ![]()
Never allow children to play with, operate, or crawl inside the freezer. Risk of child entrapment. Before you throw away your old freezer: - Take off the doors
- Leave the shelves in place so that children may not easily climb inside
- Unplug the freezer before carrying out user maintenance on it.
- This freezer can be used by children age eight years and older and persons with reduced physical or mental capabilities or lack of experience and knowledge if they are given supervision or instruction concerning the use of the freezer in a safe way and understand the hazards involved. Children should not play with the freezer. Cleaning and maintenance should not be performed by children without supervision.
- If a component part is damaged, it must be replaced by the manufacturer, its service agent, or similar qualified persons in order to avoid a hazard.
- Please dispose of the freezer according to local regulations as the freezer contains flammable gas and refrigerant.
- Follow local regulations regarding disposal of the freezer due to flammable refrigerant and gas. All refrigeration products contain refrigerants, which under the guidelines of federal law must be removed before disposal. It is the consumer's responsibility to comply with federal and local regulations when disposing of this product.
- This freezer is intended to be used in household and similar environments.
- Do not store or use gasoline or any flammable liquids inside or in the vicinity of this freezer
- Do not use extension cords or ungrounded (two-prong) adapters with this freezer. If the power cord is too short, have a qualified electrician install an outlet near the freezer. Use of an extension cord can negatively affect the freezer's performance.
Grounding requirement
This freezer must be grounded. This freezer is equipped with a cord having a grounding wire with a grounding plug. The plug must be inserted into an outlet that is properly installed and grounded.
Improper use of the grounding plug can result in a risk of electric shock. Consult a qualified electrician or service person if the grounding instructions are not completely understood, or if doubt exists as to whether the freezer is properly grounded.
Safety instruction for refrigerant
Explosion Hazard.
Keep flammable materials and vapors, such as gasoline, away from freezer. Failure to do so can result in fire, explosion, or death.
Safety instruction for refrigerant
![burn hazard]()
![]()
![burn hazard]()
Risk of Fire or Explosion. Flammable Refrigerant Used. To Be Repaired Only By Trained Service Personnel. Do Not Use Mechanical Devices. Do Not Puncture Refrigerant Tubing.
![burn hazard]()
![]()
![burn hazard]()
Risk of Fire or Explosion. Flammable Refrigerant Used. Consult Repair Manual/Owner's Guide Before Attempting To Service This Product. All Safety Precautions Must be Followed.
![burn hazard]()
![]()
![burn hazard]()
Risk of Fire or Explosion. Dispose of Properly In Accordance With Federal Or Local Regulations. Flammable Refrigerant Used.
![burn hazard]()
![]()
![burn hazard]()
Risk of Fire or Explosion Due To Puncture Of Refrigerant Tubing; Follow Handling Instructions Carefully. Flammable Refrigerant Used.
MIDEA appliances after sales website
For more information about Midea appliances after sales, please visit the tsp.midea.com
For more information about the EV and SBOM, please visit the tsp.midea.com
How to login TSP system
Use Google browser visit the https://tsp.midea.com/
Internal User:
Use MIP account and Password.
Customer:
Access: Generated by TSP (provided by administrator).
Password: abcd1234 (please revise after login in).
Midea Refrigerators
If you need to get detailed technical information from the manufacturer, please contact:
xxx@midea.com
Refrigeration Division
Overseas Sales Company
Address: No. 176, Jinxiu Avenue, Economic-Technological Development Area, Hefei, Anhui, China
Documents / Resources
References
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Midea COMPACT Series, HS-164LN, UR-BC126CM-ST Manual
Need help?
Do you have a question about the COMPACT Series and is the answer not in the manual?
Questions and answers