MAINTENANCE

Instructions for Installers and Service Engineers Only
Inlet Filter Maintenance
It is recommended that the filter is
periodically cleaned in order to maintain
the performance of the shower. It is
essential that this operation is carried out
Switch off the electricity and water supply
The inlet filter is situated inside the water
To gain access to the filter remove the
Front Cover Assembly and Bottom Corner
Trim. Unscrew the inlet filter cap on the
Inspect the O-ring for damage when the
filter is removed. Do not over tighten the
When cleaning the filter mesh, do not use
a sharp object as it will cause damage. It is
Filter Mesh
preferable to use an old toothbrush
'O' ring
Filter Cap
20
by a competent person.
at the mains.
inlet fitting.
water inlet fitting.
filter cap on reassembly.
or similar.