Online help and information www�renfert�com/25000600 Here you will find the following documents and information for download: - Operating Instructions - Quick Start Guide - Spare parts lists and spare parts drawings - Maintenance manual - FAQs, cause and rectification of faults - How to - Videos - Declarations of conformity Please note: The documents and information listed are not available for all products. Introduction Symbols used Symbols with the following meanings are used in these instructions or on the product: Danger Immediate risk of injury.
Page 4
Requirements that the operator must meet ⇒ The product may only be used by persons aged 14 or over who are familiar with the procedures and rules in a dental laboratory and have been instructed on how to use the product� Safe condition of the product Faulty or broken components, or those that are not sealed as required, may cause injuries�...
Product description General description The purpose of the "LIGHT 1" workbench light is to provide lighting for a dental technician workbench� Thanks to the option for adjusting brightness and color temperature, the light can be easily adjusted to the object to be processed� You can save custom settings or use preset combinations of brightness and color temperature�...
Accessories 2500 0510 Table clamp, workbench light 2410 0000 Renfert CONNECT stick Please check availability for your country on our website www�renfert�com/connect Startup Unpacking ⇒ Remove the equipment and accessories from the package� ⇒ Check the delivery for completeness (compare with the scope of delivery). Setup Depending on the model, the workbench light can be attached to a workbench or to a wall� Attachment to a workbench is performed using screws or using the table clamp available as an accessory part�...
4.2.2 Attachment to a workbench A Torx screwdriver (size T30) is required for the universal screws. ⇒ Press in the height adjustment lock (2, Fig. 1) and pull out the inner tube on the base to the maximum position� ⇒ On the left and right, turn the cover up slightly and push upwards (Fig 3). ⇒ Identify a suitable attachment location on the workbench� To determine the appropriate mounting location, loosen the joint lock (4, Fig.
Operation The "LIGHT 1" workbench light offers three modes with preset values for brightness and color temperature that can be selected using buttons 11, 12, and 13, as well as a standard mode� • Standard mode: The values for brightness and color tempera- ture can be adjusted individually� • Home (11): The values saved in this mode for brightness and color temperature can be adjusted and saved again for home mode�...
Setting the color temperature To adjust the color temperature, the color temperature button (14) must be pressed first. ⇒ Press the color temperature button (14). ♦ The color temperature button (14) lights up. ♦ The current color temperature value is displayed in the intensi- ty display (17). ⇒ Set the value as required using the plus/minus buttons (16). Fig. ♦ This switches back automatically to the brightness setting after approx� 5 seconds� Saving values for the home button The values used with the home button for brightness and color temperature can be adjusted and saved again�...
The lamp can be replaced� Lamps may only be replaced by a qualified electrician. Spare parts Only use accessories and spare parts that have been supplied or approved by Renfert GmbH. Using other accessories or other spare parts can lead to inadvertent accidents and damage. You can find wear parts and spare parts in the spare parts list available online, see chapter “Online help and information”�...
► The product is altered in any way other than those alterations described in the instructions for use� ► The product is not repaired by an authorized dealer or if original Renfert spare parts are not used� ► The product continues to be used despite obvious safety defects or damage�...
10 Obligations regarding information ► Information on REACH and SVHC is available on our website at www�renfert�com, in the Support area� 10.1 Disposal information for countries in the EU The equipment must be disposed of by a specialist facility. The specialist facility must be in- formed of any residue in the equipment that is harmful to health.
EG-Konformitätserklärung EC Declaration of conformity Renfert GmbH, Industriegebiet, 78247 Hilzingen / Germany Renfert GmbH, Industriegebiet, 78247 Hilzingen / Germany Hiermit erklären wir, dass das Produkt Herewith we declare that the product LIGHT 1 LIGHT 1 allen einschlägigen Bestimmungen der folgenden Richtlinien is in compliance with the relevant requirements in the entspricht: following directives: 2014/35/EU (Niederspannungsrichtlinie) 2014/35/EU (Low voltage equipment) 2014/30/EU (EMV Richtlinie) 2014/30/EU (Electromagnetic compatibility) 2011/65/EU (RoHS) 2011/65/EU (RoHS) 2009/125/EG(Öko-Design) 2009/125/EC(Eco-Design) Folgende harmonisierte Normen wurden angewendet: Harmonized specifications applied: EN IEC 60598-1:2021, +A11:2022, EN 60598-2-1:1989, EN EN IEC 60598-1:2021, +A11:2022, EN 60598-2-1:1989, EN 61347-1: 2015, EN 61347-2-13: 2014, EN 62493: 2010, 61347-1: 2015, EN 61347-2-13: 2014, EN 62493: 2010, EN IEC 55015: 2019, + A11: 2020, EN 61547: 2009, EN EN IEC 55015: 2019, + A11: 2020, EN 61547: 2009, EN 62471: 2008, EN IEC 63000: 2018 62471: 2008, EN IEC 63000: 2018 Bevollmächtigt für das Hans Peter Jilg Authorised to compile the technical Hans Peter Jilg...