synapsis ® home 2
I
M
NSTRUCTION
ANUAL
healing power of colors

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the synapsis home 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Esogetics synapsis home 2

  • Page 1 synapsis ® home 2 NSTRUCTION ANUAL healing power of colors...
  • Page 3: Table Of Contents

    Table of Contents General Description, Purpose and Effect ... . .4 1.1 General Description ......4 1.2 Purpose .
  • Page 4: General Description, Purpose And Effect

    The Synapsis Home 2 instrument is used in the clinical setting or at home. The Synapsis Home 2 instruments can be used by all users star- ting at the age of 9, independent of size, weight or gender.
  • Page 5: First Use - Proper Handling

    (illustr. 2). illustr. 2 – Instrument/ socket The connector cable of the Synapsis Home 2 instrument posses- ses an interface for the attachment of certified sticky electrodes (one time use electrodes) and certified wrist cuffs.
  • Page 6 7 – Synapsis Home 2 device with its buttons from above After the selection of the program the application is activated by pushing the button.
  • Page 7 The instrument will automatically shut down, if no treatment is active and no buttons have been pressed for the past 30 seconds. This will conserve your battery life. The round plug may stay in the socket in between treatments. If you should not be using the device for a longer period, then you may unplug it.
  • Page 8: Contraindications, Precautions And Adverse Effects

    • active implants. The Synapsis Home 2 device may never be used in the vicinity of a therapeutic shortwave or microwave device (minimum dis- tance requirement 1 m = 3 ft.) The simultaneous treatment with the Synapsis Home 2 System and a high-frequency surgical instrument is inadmissible.
  • Page 9: Inspection, Maintenance And Repairs

    Attention: Never clean the device with organic solvents or abrasive cleansers. These substances may damage the casing or the keypad. To clean the cuffs please follow the instructions of the manufacturer. Observe the manufacturer’s recommendations in regard to the life expectancy of the wrist cuffs. 6.
  • Page 10: Maintenance

    6.3 Maintenance There is no special maintenance required for the instrument. In case of uncertainties or complaints about the functionality, please contact the manufacturer directly: Esogetics GmbH in Bruchsal, Germany. Only the manufacturer or persons appointed by the manufac- turer are authorized to repair or make changes to the instru- ment.
  • Page 11: Technical Data Of The Control Uni

    8. Technical Data of the Control Unit Type designation: Synapsis Home 2 Power supply: 9 V E-Block / 6LR61 / 6LF22 Nominal current: 17 mA Type of construction: Hand-held unit Protection rating: Humidity protection rating: IP 65 Duration of treatment:...
  • Page 12: Applied Standards And Guidelines

    Telephone: +49 (0) 7251/800 10, Fax: +49 (0) 7251/800 155 Web: www.esogetics.com Mail: Info-de@esogetics.com Download of the instruction manuals under: www.esogetics.com/downlowds Esogetics is a manufacturer of wellness equipment as well as a registered medical device manufacturer and. We adhere to a certified and monitored quality management system.
  • Page 13: Appendix

    Appendix 10. Symbols: Device on Device off Scroll down (program selection) Scroll up (program selection) Select the highlighted program Terminate the running program immediately The conformity of the device with the relevant EU directives is validated through the CE sign. Refers to the necessity for the user to consult the manual.
  • Page 14 X X J J J J - x x x x x Continuous serial no. Production year Device type (SP W = „point 2“; SW W = „wave 2“; SH W = „home 2“) Example: SH W 2023 03937 = synapsis home 2 from 2023 with the no. 3937.
  • Page 15: Appendix 1 - Emv-Tables

    Appendix 1 EMV Tables...
  • Page 16 Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the synapsis home 2, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.
  • Page 17 Guidance and manufacturer’s declaration - electromagnetic immunity The synapsis home 2 is intended for use in the electromagnetic environment specified below. The customer or the user of the synapsis home 2 should assure that it is used in such an environment(home healthcare environment –...
  • Page 19 Name of the program Description of the fields of application t/min Relaxation Programs Rest 1 Program for deep, inner relaxation Rest 2 For any present time stress Supportive in problems of falling or staying Sleep 1 asleep Sleep 2 Regulates particularly the sleep rhythm Dream Stimulating dream activity Conflict Resolution Programs...
  • Page 20 Hildastr. 8 • D-76646 Bruchsal Tel. +49 (0 )72 51 / 80 01 -0 • Fax 80 01 55 info-de@esogetics.com www.esogetics.com esogetics GmbH – Niederlassung Hirschmattstr. 16 • CH-6003 Luzern Tel. +41 (0)41/4 20 58 36 • Fax 4 20 59 36 info-ch@esogetics.com www.esogetics.com...