Installing the Outer Rails to the Rack
1.
Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2.
Adjust both the short and long brackets to the proper distance so that the rail
fi ts snugly into the rack.
3.
Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
4.
Repeat steps 1-4 for the left outer rail.
Figure 2-3: Assembling the Outer Rails
Outer Rail
Secure to the
Front of the Rack

Installing the Server into a Rack

1.
Confi rm that chassis includes the inner rails (attached to the chassis beneath
the rail extentions) and rail extensions (B). Also, confi rm that the outer rails
(C) are installed on the rack.
2.
Align the chassis rails extentions (B), with the front of the rack rails (C).
3.
Slide the chassis rail extensions into the rack rails, keeping the pressure even
on both sides (you may have to depress the locking tabs when inserting).
When the server has been pushed completely into the rack, you should hear
the locking tabs "click" into position.
4.
(Optional) Insert and tightening the thumbscrews that hold the front of the
server to the rack.
Secure Outer Rails
Together
2-6
Secure to the
Rear of the Rack