R1-1K1
R1-1K6
R1-2K2
R1-2K5
R1-2K7
R1-3K
R1-3K3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R1 Mini Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Renac R1 Mini Series

  • Page 1 Series User Manual R1-1K1 R1-1K6 R1-2K2 R1-2K5 R1-2K7 R1-3K R1-3K3...
  • Page 3: Table Of Contents

    Content 1. Introduction ..............................4 1.1 Introduction ..................................4 1.2 Applied designations ............................... 4 1.3 Important safety information ............................5 1.4 System sizing .................................. 5 2. Technical description of inverters ........................ 6 2.1 Mechanical design ................................6 2.2 Electrical system design ..............................7 2.3 Technical data ................................
  • Page 4 4.5.1 Grid Code ................................25 4.5.2 Grid ..................................26 4.5.3 Feed in limit (CT) ..............................26 4.5.4 Feature ................................27 4.5.5 New password ..............................27 4.5.6 Reset .................................. 27 4.5.7 Software update ..............................28 4.6 System switch ................................28 4.7 Self-Test in accordance with CEI 0-21 (Applies to Italy only) .................... 28 5.
  • Page 5: Copyright Declaration

    Copyright Declaration All rights to the content of this manual are owned by RENAC Power Technology Co., Ltd. (hereinafter called as ‘RENAC Power’). Any corporation or individual should not plagiarize, partially or fully copy it, and reproduce or distribute it in any form or means without prior written permission from RENAC Power.
  • Page 6: Introduction

    R1 Mini Series User Manual 1. Introduction 1.1 Introduction This manual describes solar inverters: R1-1K1 / R1-1K6 / R1-2K2 / R1-2K5 / R1-2K7 / R1-3K / R1-3K3. These inverters are transformerless based inverter. Please read the safety instructions in this manual first. Throughout the manual it is assumed that the reader is familiar with AC and DC installations and knows the rules and regulations for electrical equipment and for connecting it to the utility AC grid.
  • Page 7: Important Safety Information

    The inverter incorporates an input power limiting device which automatically keeps the power at levels that are safe for the inverter. The limitation depends mainly on internal and ambient temperatures. The limitation is calculated continuously and always allows the maximum possible amount of energy to be produced. Please use the tool supplied by Renac Power when dimensioning a photovoltaic system.
  • Page 8: Technical Description Of Inverters

    R1 Mini Series User Manual 2. Technical description of inverters 2.1 Mechanical design Figure 2-1 shows the outline dimensions of R1-1K1 / R1-1K6 / R1-2K2 / R1-2K5 / R1-2K7 / R1-3K / R1-3K3. Figure 2-1 Outline dimensions Figure 2-2 shows the electrical terminals of R1-1K1 / R1-1K6 / R1-2K2 / R1-2K5 / R1-2K7 / R1-3K / R1-3K3.
  • Page 9: Electrical System Design

    R1 Mini Series User Manual 2.2 Electrical system design For safety reasons, the use of a DC switch is recommended. Between the PV modules and the power modules may be mandatory in some countries Figure 2-3 Block diagram of the inverter system 2.3 Technical data...
  • Page 10 R1 Mini Series User Manual Model R1-1K1 R1-1K6 R1-2K2 R1-2K5 R1-2K7 R1-3K R1-3K3 Inrush Current (Peak and 1 (20ms) Duration) (A) Maximum Output Overcurrent 14.6 22.8 24.6 27.2 Protection (A) Efficiency Max. Efficiency 97.5% 97.5% 97.5% 97.5% 97.6% 97.6% 97.6% Euro Efficiency 96.9%...
  • Page 11: Grid Codes

    R1 Mini Series User Manual 2.4 Grid codes National/Regional Grid Code Description VDE4105-DE Germany power Grid, meet Grid standards “VDE-AR-N-4105”. CEI0-21 Italy power Grid. Australia A Australia A power Grid. RD1699 Spain power Grid. EN50549 Default EN50549 Grid setting. EN50549-DK-W West Denmark power Grid.
  • Page 12: Installation And Startup

    R1 Mini Series User Manual National/Regional Grid Code Description Thailand power Grid. Thailand power Grid. Grid voltage range: 160-280V. MEA-W Grid frequency range: 47-52Hz. Brazil-LV 120V 60Hz voltage of grid L to N (R3-10-15K-LV only, others reserved). EN50549-DK-E East Denmark power Grid.
  • Page 13: Package Information

    R1 Mini Series User Manual 3.1 Package information PV cable terminal(+) with PV cable terminal(-) with Mounting Panel * 1 a corrugated pipe * 1 a corrugated pipe * 1 Inverter * 1 AC terminal & related Expansion tube M6 &...
  • Page 14: Installation Position

    R1 Mini Series User Manual 3.3 Installation position 1) The installation method and mounting location must be suitable for the inverter's weight and dimensions. 2) Mount on a solid surface. 3) Select a well-ventilated place sheltered from direct sun radiation.
  • Page 15 R1 Mini Series User Manual Figure 3-5 3. Place the inverter on the wall-mounted bracket. Figure 3-6 4. Place install the fix screw to fix the inverter. 1.5N.m Figure 3-7...
  • Page 16: Electrical Connection

    R1 Mini Series User Manual 3.5 Electrical connection 3.5.1 Earth connection One can additionally earth the inverter enclosure of a second earthed or equipotential bonding, which is required under local regulations. This prevents touch current if the original protective conductor fails.
  • Page 17 R1 Mini Series User Manual 2. Crimp the terminals with crimping pliers and set the parts on the cable. Insert the terminal holes in sequence. Figure 3-10 3. Fully insert the conductors to the corresponding terminal and tighten the screws with the torque 0.8 N.m. Pull cables outward to check whether they are firmly installed.
  • Page 18: Pv Connection (Dc Input)

    R1 Mini Series User Manual 3. Remove the female end of the cable to unlock the account. Figure 3-15 3.5.3 PV connection (DC input) 1) Before connecting PV string, make sure DC switch is turned off. 2) Make sure PV string polarity confirms with DC connector, otherwise, it will cause damage to inverter.
  • Page 19: Communication

    R1 Mini Series User Manual 3.5.4 Communication Overview of communication ports: Figure 3-17 Communication ports *The RSV_485A and RSV_485B ports are occupied when the AFCI function of the inverter is enabled. 3.5.4.1 WIFI/4G/Ethernet Communication (Optional) Connect the WIFI / 4G / Ethernet module produced by manufacturer to the COM port of inverter. After successful connection, information such as power generation and running state of the inverter can be viewed via the App on the phone.
  • Page 20: Ct Or Meter Connection (Optional)

    R1 Mini Series User Manual Local mode WIFI Ethernet Bluetooth Router Base Station Internet Wireless Mobile App Figure 3-18 3.5.4.2 CT or Meter Connection (Optional) The inverter is equipped with the feed-in power limit function, and the communication port on inverter is "CT/Meter"...
  • Page 21: Drm Connection

    R1 Mini Series User Manual Gird Meter Loads Figure 3-20 3.5.4.3 DRM connection The inverter supports the demand response modes as specified in the standard AS/NZS4777. The inverter has integrated a terminal for connecting to a DRED. The details please refer to figure 3-17, and for CEI standard, DRM0 is the Dl port.
  • Page 22: Starting The Inverter

    R1 Mini Series User Manual 3.6 Starting the inverter Before turning on the inverter, please confirm: 1) Three AC wires (PE/L/N) cable correctly connected to the inverter AC side through AC circuit breaker; 2) The DC cable is connected correctly to the DC side of the inverter through the DC circuit breaker; please pay attention to the cable connected to the string correctly and its polarity;...
  • Page 23: User Interface

    R1 Mini Series User Manual 4. User interface 4.1 Led and key Figure 4-1 LED display Name Description The inverter has connected to the grid and is operating normally. 1. The inverter is powered on and in the waiting stage.
  • Page 24: Lcd Display

    R1 Mini Series User Manual 4.2 LCD display Mean Structure:...
  • Page 25 R1 Mini Series User Manual ====Settings==== ====On-Grid==== ===Grid Code=== Comm Addr >Grid Code >EN50549 Key Mute Grid >Advanced* Feed in limit ======Grid====== ==Volt Protect== ==Volt Protect== ====Password==== >Volt Protect >Level-1 OV >Level-1 UV Freq Protect 000.0V 000.0V 0 0 0 0...
  • Page 26: History

    R1 Mini Series User Manual 4.3 History 4.4 Setting There are two types of confirmation in the setting function. 1. Press and hold the OK button for 2~3 seconds to confirm the selection. If the setting is successful, ‘Set Succeed’ will be displayed below;...
  • Page 27: Communication Address

    R1 Mini Series User Manual 4.4.3 Communication address 4.4.4 Key mute Normal =====Menu===== ====Settings==== ===Key Mute=== INV-P: Status Date&Time >Disable History Comm Addr XX-XX XX:XX:XX >Settings >Key Mute ===Key Mute=== >Enable 4.5 Advanced* setting First of all, if the user wants to enter the Advanced* setting interface, verify the user identity and enter the default password ‘0000’...
  • Page 28: Grid

    R1 Mini Series User Manual 4.5.2 Grid 4.5.3 Feed in limit (CT) Step 1: Enable the CT. Step 2: Set the power value.
  • Page 29: Feature

    R1 Mini Series User Manual 4.5.4 Feature Note: To enable the AFCI function, you need to set it up. When electric arcs occur, the inverter will alarm and lock out to provide protection. You need to manually clear the alarm on the inverter so that it can work properly.
  • Page 30: Software Update

    R1 Mini Series User Manual 4.5.7 Software update Note: The AFCI can only be upgraded when the AFCI function is enabled. 4.6 System switch Normal =====Menu===== ===SYS Switch=== ===SYS Switch=== INV-P: History >ON >OFF Settings XX-XX XX:XX:XX >SYS Switch 4.7 Self-Test in accordance with CEI 0-21 (Applies to Italy only) The self-test is only required for inverters, which are commissioned in Italy.
  • Page 31: Warranty

    R1 Mini Series User Manual 5. Warranty 5.1 Warranty claim procedure Please report defective device with a brief error description and SN code to our service mail or service hotline for registration. Alternatively, please contact your specific dealer or installer if your unit is defective or faulty. To claim the warranty under the warranty terms of factory, you need to supply us with the following information and documentation regarding the faulty unit: 1) Product Model and the Serial Number.
  • Page 32: Troubleshooting And Maintenance

    R1 Mini Series User Manual 6. Troubleshooting and Maintenance 6.1 Troubleshooting Once a fault occurs in the inverter, the fault information can be displayed on screen or the App interface. Fault codes and check methods are as follows: LCD display Possible actions Grid voltage too low.
  • Page 33: Maintenance

    Restart the inverter only after removing the fault that impairs safety performance. As the inverter NOTICE contains no component parts that can be maintained, never arbitrarily replace any internal components. For any maintenance need, please contact Renac Power. Otherwise, Renac Power shall not be held liable for any damage caused.
  • Page 34: Routine Maintenance

    R1 Mini Series User Manual 6.2.1 Routine Maintenance Item LCD display Period Check the temperature and dust of the inverter. Clean the inverter enclosure if necessary. Check if the air inlet Six months to a year (- depend on the...
  • Page 36 R1 Mini Series User Manual...