Download Print this page

Firstech DC3 Master Manual page 40

Hide thumbs Also See for DC3:

Advertisement

FO = Default Feature Option
3-12 Confirmation horn chirp pulse duration: Used to control the length of the pulse sent to the horn for command confirmations. This is useful if the horn chirps
are either too long or too short.
FO1 - Pulse of 20ms
FO2 - Pulse of 30ms
FO3 - Pulse of 40ms
FO4 - Pulse of 45ms
FO5 - Pulse of 50ms
FO6 - Pulse of 60ms
FO7 - Pulse of 100ms
3-13 Shock sensor input behavior: Controls the shock sensor input behavior for both the DAS port (4-pin red) and sensor 2 port (4-pin green).
FO1 - Disable: Both ports are disabled
FO2 - Enabled: Both ports are enabled for warn-away and full shock.
FO3 - Warn away only: Only the warn-away triggers will be enabled.
FO4 - Full shock only: Only the full shock triggers will be enabled.
3-14 Analog sensor (-) input behavior: Controls M3 pin-10 (Tan/silver dot) wire. This input can be configured for a variety of different special applications. Read the
different option descriptions carefully before making your selection.
FO1 - Disable
FO2 - Warn-away only: A (-) input will trigger a warn-away notification similar to that of the shock sensor.
FO3 - Full shock only: A (-) input will trigger a full alarm similar to that of the shock sensor.
FO4 - Normally closed alarm: The input will expect to see (-) constant while the system is armed. If the (-) signal is lost, the alarm will trigger.
FO5 - Zone 2 passive 15: This input will always passively arm 15 seconds after zone 2 is closed if the vehicle is not running under key start or in valet mode.
Zone 2 will disarm with the system but will ALWAYS passively arm itself regardless if the alarm is in active arming mode. A (-) input is needed to trigger
Zone 2.
FO6 - Zone 2 passive 30: This input will always passively arm 30 seconds after zone 2 is closed if the vehicle is not running under key start or in valet mode.
Zone 2 will disarm with the system but will ALWAYS passively arm itself regardless if the alarm is in active arming mode. A (-) input is needed to trigger
Zone 2.
3-15 Alarm & Starter kill control from OEM keyless: When enabled, lock and unlock commands sent from the vehicle's OEM fob will also arm/disarm the HC alarm
and/or starter-kill (if enabled).
FO1 - Disable
FO2 - Enable with remote notification: OEM commands will control CM alarm and arm/disarm and notifications will be sent to iDatastart 2-way
transmitters (if installed).
FO3 - Enable without remote notification: OEM commands will control CM alarm and arm/disarm but notifications will NOT be sent to iDatastart 2-way
transmitters (if installed).
U.S. Patent No. 8,856,780 CA 2759622
Automotive Data Solutions Inc. © 2023
Option Menu Descriptions
Page 40
20250402

Advertisement

loading
Need help?

Need help?

Do you have a question about the DC3 and is the answer not in the manual?

Subscribe to Our Youtube Channel