Setting 4-20mA Range
Measuring the tank is one of the most important aspects in
configuring the sensor. When measuring the tank, take into
account the location of the sensor with respect to fittings, risers,
dome tops and bottoms, and identify where the measurements
are taken from the sensor.
The Range is the overall distance from the Max or Full Liquid
Level to the Lowest Liquid level | Normally this would be when
the tank is Empty
Min Configuration = 4mA setting.
?
With flat bottom tanks, the Range and Empty Configuration
values can be the same.
Max Configuration = 20mA setting.
?
The distance from the tip of the sensor to the highest liquid or
full level
Display Description
Real-Time
Value
Temperature
Reading
25-0724 © Icon Process Controls Ltd.
2 Series
®
Display 1
Damping Value
mA Reading
20 mA
4 mA
Temperature
Reading
Level / Distance
Bar Indication
mA Reading
Measurement
Location
100%
Max Config
Range
0%
Display 2
Echo Strength