LEDFluorescentMicroscope STM-2036FB(LED)/FT(LED) Instruction Manual This manual is written for STM-2036FB(LED)/FT(LED) Series LED fluorescent biological microscope. To ensure the safety, obtain optimum performance and to familiarize you fully with the use of this microscope, it is recommended strongly that you study this manual thoroughly before using the microscope and retain this manual in an easily accessible place near the work desk for future reference.
Attentions! ! 1) Purpose The series microscope is used only for microscopic observation, not available for other purpose, otherwise result in equipment damage. 2 Disassembly only by the professionals. The microscope has been adjusted before shipping, Unprofessional-person should not disassemble and remove any other parts.
Microscope Body Part STM-2036FB(LED)/FT(LED) series LED fluorescent biological microscopes are designed for college teaching, Medical and clinical identification. The microscope with modern design, steady structure, convenient operation and clear image is suitable for observing various biological specimens, they are mostly applied in colleges and hospitals. 1.
2. Specifications 2.1 Total magnifications Objective Total Magnifications 100X (Optional) Eyepiece 100X 200X 400X 1000X 160X 320X 640X 1600X 1.2 Objectives Infinite E-Plan Numerical Objective Resolving Working Objectives Aperture (N.A.) Field Power Distance 0.10 2.8µm 6.73mm 0.25 1.1µm 4.19mm 20X (S) (Optional) 0.40 0.69µm 2.14mm...
Page 6
the desk. Make sure the supply voltage meets the instrument’s requirement and the power switch is off. Installation Instruction Fig.: 1. Turn the binocular (trinocular) head to working position; 2. Put out the dust cover of the eyepiece tube; 3. Insert into the eyepiece; 4.
4. Operation 4.1 Bright field operation process instruction 1) Turn power switch, Turn on Switch L, and turn Potentiometer K. adjust light Put the sample on stage ④ , (open the clamp 2) Put the sample C, and put the sample into it), turn stage knob H to put the sample into optical path.
6. Maintenance 6.1 Clean microscope 6.1.1 Don’t touch the lens with hand, Dust on lens should be cleaned by soft brush or absorbent cotton or cleaned by absorbent cotton, lens paper with the mixture of alcohol and ether (proportion 1:4). 6.1.2 Alcohol and ether all are burnt early, please take them away from fire.
LED Fluorescent Part 1. Applications Some objects can emit a ray which wavelength is longer than that of the excitation light when irradiated. This ray is called fluorescence, and observers can study the objectives through fluorescence microscope using the phenomenon. Fluorescence microscope has wide applications in basic theory research and clinical diagnosis about medicine, biology, as well as analysis and test in industry, agriculture, stockbreeding, criminal investigation, legal medical appraise, environmental protection etc.
3. Instruction BFL-LED2 sliding two-group LED fluorescence device can meet various need for configuration through the building modular collocation. BFL-LED2 sliding two-group fluorescence device with fluorescence LED light source, which has excellent feature ,without waiting startup time for lamp, low voltage, no fever on lamp house etc., standard equipped with B,G, also can choose B, G, UV and V to install as required.
Page 11
20 power box output socket 21 single group LED fluorescence light box 22 power socket of light box 23 output socket of lithium battery power box 24 external power connector 1) Take all parts from the package, remove the protective package and place it on the vacant bench. 2) Turn fluorescence device and put the protective plate in with the screw, then tighten it by wrench.
5. Fluorescence Device Operation Please adjust microscope in bright field method and operate fluorescence attachment as follows: LED Fluorescence Device Operational Parts Marking Graphs 17 condenser adjustable ring 18 LED switch shift lever 19 brightness adjusting knob 20 power switch 21 charging indicator 22 fuse tube (Single group LED lamp source is similar as two group lamp source)
house (the instrument has been adjusted before dispatching, in normal case, it would be better not to center again). 10) When use multigroup light source , can choose just compare with module conversion position witch in front of the fluorescence device . 11) Rechargeable Lithium power source specially for LED illumination can be used above 10 hours continuously without external power supply.
Trouble shooting In the period of using this series microscope, if there is any trouble occurs, please referring to the following sheet listed some common troubleshooting resolve them. Trouble Causation Remedy Plug is unreliable Plug in again Switch on but bulb dark Bulb is broken Change bulb Fuse is broken...
Image observed by two Interpupilary distance isn’t Adjust interpupilary eyes aren’t in adjusted correctly distance according to two eyes superposition entirely. It is easy for eyes to be Diopter isn’t adjusted correctly Readjust diopter tired during observing Outfits STM- STM- Model 2036FB(LED) 2036FT(LED)