DISPLAY INDICATIONS 09. CONNECTIONS TO THE CONTROL BOARD The different types of packaging (cardboard, plastic, etc.) must be ROSSO PRO CONTROL BOARD subject to selective collection for recycling. Separate packaging PHOTOCELLS WITH TEST CONNECTION and recycle it responsibly.
01. SAFETY INSTRUCTIONS GENERAL WARNINGS • Children shouldn’t play with the product or opening devices to avoid the motorized door or gate from being triggered involuntarily. • This manual contains very important safety and usage information. • If the power cable is damaged, it must be replaced by the Read all instructions carefully before beginning the installation/ manufacturer, after-sales service or similarly qualified personnel usage procedures and keep this manual in a safe place that it can...
• Pay special attention to the danger of falling objects or uncontrolled movement of doors/gates during the installation or operation of MOTORLINE ELECTROCELOS SA. this product. Travessa do Sobreiro, nº29 4755-474 Rio Côvo (Santa Eugénia)
Inside the package you will find the following components: ROSSO PRO is an automation system with the possibility of installing a Wi-Fi module for remote management and control. The control board that equips this motor allows motor management with a quadrature encoder, ensuring mo- 01 •...
03. THE AUTOMATISM MANUAL UNLOCK REMOVING TOP COVER The ROSSO PRO unlocking system is very simple and practical to use. To do so just pull the lever down (figure 03). To block simply pull the lever to the original position.
CHANGING COURTESY LEDS INFORMATION PRE-INSTALLATION For a correct operation of ROSSO PRO, you must take into account the following parameters before the installation: • Read all steps on this manual at least once in order to get acquainted with the installation and configuration process.
Page 8
04. INSTALLATION 04. INSTALLATION FIXING THE MOTOR IN RAILS AUTOMATISM INSTALLATION With standard rails, you can only automate doors with maximum height of 2500mm. 125-175 100-150 01 • Attach the rail’s support plate to the lintel, as visible in the image 15. In the image 16 if can be seen the distance to keep between the door rail and support plate’s upper part (125-175mm).
Page 9
04. INSTALLATION 04. INSTALLATION AUTOMATISM INSTALLATION AUTOMATISM INSTALLATION DETAIL 19 05 • After rising the rail and mark the holes, you should fix the plate with screws. 03 • Place the rails fixing plate on the ceiling approximately in the middle of the steel rail as visible in After that, you should use bracket to reinforce the attachment, this time near the motor (image 23).
06. POST-INSTALLATION 06. POST-INSTALLATION STOPPER AT THE OPENING STRETCH RAIL’S CHAIN The automatism needs a stopper in the opening and closing to always control the courses. In closing maneuvers, the ground will be the stopper, but in the opening maneuvers it is necessary to create a stopper on the steel rail, to ensure that the trolley always stop in the correct place.
06. CONTROL BOARD 06. CONTROL BOARD LEGEND LEGEND NC input for pedestrian door Connector 1 (Exterior) Connections NO input for opening pulse NC input for photocells Common +24V (max 5W) External flashing lamp (max 24V 5W) RPRO-MOTION Power input 24Vac 50/60Hz MBAT26V2000 Lithium Battery Input Motor output (24Vdc 130W) RPRO-HUM...
06. CONTROL BOARD 07. PROGRAMMING LEGEND TRANSMITTERS • Display FACTORY FUNCTION VALUE • Main Menu • Programming Transmitters Programming Transmitters for full opening • Up Programming Transmitters for pedestrian opening • Down • USB Type-C connector for MCONNECT LINK Transmitters for pedestrian opening. Record up to 100 Transmitters for full opening and 100 Transmitters for pedestrian opening, for a total of 200 Transmitters.
07. PROGRAMMING 07. PROGRAMMING MMR15 MODULE MMR15 MODULE MMR15 MODULE CONFIGURATION CHECK SIGNAL STRENGTH This parameter allows you to select the channels you want to monitor in terms of the received The 868 MHz Plug-and-play receiver module is designed to record up to 2 MX14 per channel. It has two independent channels where Channel 1 (CL) allows the closing direction to be reversed and Channel 2 (St) offers signal strength.
07. PROGRAMMING 07. PROGRAMMING MENU FUNCTIONS "P" PROGRAM "P" FACTORY COURSE PROGRAMMING MENU FUNCTION MIN. MAX. STATE PAGE VALUE Manual programming Manual programming Course programming Motor direction This menu allows you to manually program the motor. Opening slowdown Before you begin, make sure that all pre-installation requirements (p. 7B) have been met. Manual programming allows you to quickly set the door opening and closing positions.
Page 16
07. PROGRAMMING 07. PROGRAMMING PROGRAM "P" PROGRAM "P" ADJUSTING THE SLOWDOWN POSITION AND RAMPS FACTORY FACTORY SPEED AND SENSITIVITY ADJUSTMENT VALUE VALUE Allows you to adjust the slowdown course when opening and closing. Speed adjustment at opening Position of the beginning of slowdown at Opening This function is used to select the desired speed during the opening maneuver.
Page 17
07. PROGRAMMING 07. PROGRAMMING PROGRAM "P" PROGRAM "P" PAUSE TIME PHOTOCELL 1 PROGRAMMING FACTORY FACTORY Automatic closing begins after the programmed pause time, counted from the end of the Allows you to program the behavior of the LE Security Input VALUE VALUE opening maneuver or from the moment the door is stopped during opening.
Page 18
07. PROGRAMMING 07. PROGRAMMING PROGRAM "P" PROGRAM "P" PROGRAMMING FOR LA AND SE SECURITY INPUT PROGRAMMING FOR LA AND SE SECURITY INPUT FACTORY FACTORY VALUE VALUE Allows you to program the behavior of the LA (8K2) and SE(OSE) safety inputs. Allows you to program the behavior of the LA (8K2) and SE(OSE) safety inputs.
Page 19
07. PROGRAMMING 07. PROGRAMMING PROGRAM "P" PROGRAM "P" OPERATING LOGIC OPERATING LOGIC FLASHING LAMP/LED/RLY FACTORY FACTORY VALUE VALUE Allows you to define the operating logic of the automation. Allows you to set the flashing light (LAMP)/LED/RLY operating mode. Operation in automatic mode The light turns on during all door movements, whenever OPEN - CLOSE - OPEN - CLOSE the door is stopped the light will turn off.
07. PROGRAMMING 07. PROGRAMMING PROGRAM "P" "E" MENU FUNCTIONS FACTORY FLASHING LAMP FACTORY MENU MIN. MAX. FUNCTION STATE PAGE VALUE VALUE Allows you to set the flashing light (LAMP)/LED/RLY operating mode. Disable Human presence Intermittent (opening and closing) Active on closing HUMAN PRESENCE Active on opening and closing The output will remain flashing during the opening and...
Page 21
07. PROGRAMMING 07. PROGRAMMING PROGRAM "E" PROGRAM "E" FACTORY FACTORY HUMAN PRESENCE /STOP INPUT HUMIDITY SENSOR VALUE VALUE Disable Human presence Allows you to enable/disable the sensor The "Human presence" function ensures that the door only moves while the opening Sets the percentage of the total course, which the door will open when the humidity button remains pressed, allowing the door to move.
Page 22
07. PROGRAMMING 07. PROGRAMMING PROGRAM "E" PROGRAM "E" FACTORY FACTORY FOLLOW ME SET RLY/LAMP ACTIVATION TIME VALUE VALUE Function disabled RLY/LAMP output time with RPRO-MOTION sensor Detection with door fully open Allows you to define the time that the LED/RLY output remains activated after motion is If the safety photocells are interrupted with detected.
Page 23
07. PROGRAMMING 07. PROGRAMMING PROGRAM "E" PROGRAM "E" FACTORY SLOWDOWN SPEED RESET - RESET FACTORY VALUES VALUE FACTORY This function allows you to program the motor speed during the slowdown phase of an opening maneuver. VALUE The higher the level, the faster the slowdown. Disabled Adjusting the slowdown speed during opening Reset triggered...
08. DISPLAY DISPLAY INDICATIONS MENU DESCRIPTION MENU DESCRIPTION In the stopped position, fully open Processing error In the stopped position, intermediate position Overvoltage error In the stopped position, fully closed Under voltage error Opening pulse button pressed Initialization error Full opening button pressed Encoder error Full close button pressed EEPROM memory error...
09. CONTROL BOARD CONNECTIONS 09. CONTROL BOARD CONNECTIONS PHOTOCELLS WITH TEST CONNECTION MMR15 RECEIVER MODULE (OPTIONAL) This control board allows the installation of a receiver for the MX14 radio safety edge device, simplifying the entire installation without the need for external accessories or additional wiring to the control board. This way, when you want to add safety edges or magnetic contacts via radio, simply install the MMR15 module 2 3 4 Photocells...
10. TROUBLESHOOTING CONTROL BOARD ERROR MAP Display Description Cause Solving the problem • Opening. • Motor opening (Motor in opening maneuver) • Closing. • Motor closing (Motor in closing maneuver) DELETE Transmitter • All remotes controls have been deleted. • If all remotes controls are deleted. •...
• The door moves If the motor does not work, remove it and send it to the MOTORLINE technical services for diagnosis. on the door. easily? 1 • Make sure the display and the courtesy A) It closed: B) Didn’t close:...
Need help?
Do you have a question about the ROSSO PRO and is the answer not in the manual?
Questions and answers