Setting PrOG ON (Programmable Thermostat Mode) - Programming
The automatic operation of the NEVE PRO thermostat is based on daily phases, which can range
from a minimum of 2 to a maximum of 8 phases (by default, there are 6 phases, but you can exclude
or add more).
What are daily phases?
The daily phase is a command given to the thermostat. Through it, the user sets an ambient tempe-
rature starting from a specific time. This temperature will be maintained until another command (ano-
ther phase) is given, which will set a new temperature at a different time. The alternation of daily
phases determines the temperature variations throughout the day or the on/off cycles of the system.
If the programming is set with "odd" phases (phases 1, 3, 5, 7) at higher temperatures and "even"
phases (phases 2, 4, 6, 8) at lower temperatures, the thermostat will adjust accordingly.
12
Plikc S.r.l. - Via del Lago Terrione, 83 - 00165 Roma - info@plikc.com - www.plikc.com
Example Setup
Let's say you want to turn on the radiators at 7:00 AM, turn them off at 9:00 AM, then turn them back
on at 12:00 PM, turning them off again at 2:00 PM, then turn them back on at 4:00 PM and turn them
off again at 6:00 PM, and finally turn them back on at 8:00 PM and turn them off again at 10:00 PM.
You will set the thermostat as follows:
Phase 1: 7:00 AM, set to 20°C.
Phase 2: 9:00 AM, set to 15°C.
Phase 3: 12:00 PM, set to 20°C.
Phase 4: 2:00 PM, set to 15°C.
Phase 5: 4:00 PM, set to 20°C.
Phase 6: 6:00 PM, set to 15°C.
Phase 7: 8:00 PM, set to 20°C.
Phase 8: 10:00 PM, set to 15°C.
With this programming, when it's 7:00 AM, the thermostat will enter Phase 1 and will turn on the
radiators to reach 20°C. This will continue until 9:00 AM, when Phase 2 set to 15°C will turn off the
radiators. At 12:00 PM, Phase 3 will turn the radiators back on to 20°C, and this cycle will continue
throughout the day.
Important: If the internal temperature drops below 15°C for any reason, the radiators will turn on
before the next phase starts. This allows the thermostat to automatically maintain the desired tem-
perature and adjust for any sudden drops in room temperature.
Plikc S.r.l. - Via del Lago Terrione, 83 - 00165 Roma - info@plikc.com - www.plikc.com