Connection to Zone Valve or Other Load (220/230Vac)
Connect the two wires to terminals 3 (NO) and 2
(COM).
Note: It is recommended to connect the live wire
(L) to terminal 2 (COM).
L N
Zone Valve
8
Plikc S.r.l. - Via del Lago Terrione, 83 - 00165 Roma - info@plikc.com - www.plikc.com
Power On, Power Off, Anti-Freeze Mode
The NEVE PRO is turned on and off using the power button ON/OFF.
When the device is off (OFF), it automatically enters Anti-Freeze mode, indicated on the display with
the OFF symbol.
The Anti-Freeze function allows you to set a minimum internal temperature between 0.5°C and 15°C
(default: 5°C), which is maintained when the thermostat is off. This helps to protect the system if the
external temperature drops below freezing, preventing the pipes from freezing and getting damaged.
The Anti-Freeze function can be deactivated through the Settings menu by selecting AntiOff.
Note:
In Heating mode (HEAT), when the set temperature is higher than the detected temperature, the
symbol "flame" will appear on the display, and the heating system will turn on.
In Cooling mode (COOL), when the set temperature is lower than the detected temperature, the
symbol "fun" will appear on the display, and the cooling system will turn on.
Plikc S.r.l. - Via del Lago Terrione, 83 - 00165 Roma - info@plikc.com - www.plikc.com
9