Download Print this page
Chamberlain CSL24UL-MC Installation Manual
Chamberlain CSL24UL-MC Installation Manual

Chamberlain CSL24UL-MC Installation Manual

Commercial dc vehicular slide gate operator

Advertisement

Quick Links

VEHICULAR SLIDE GATE OPERATOR
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
COMMERCIAL DC
INSTALLATION MANUAL
EXTERNAL SAFETY
EXTERNAL SAFETY
REQUIRED. SEE SAFETY
REQUIRED. SEE SAFETY
SECTION FOR
SECTION FOR
UL 325 ENTRAPMENT
UL 325 ENTRAPMENT
PROTECTION
PROTECTION
REQUIREMENTS
REQUIREMENTS
DEVICES
DEVICES
• THIS PRODUCT MUST BE INSTALLED AND
SERVICED IN ACCORDANCE WITH THIS
MANUAL BY A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
• This model is for use on vehicular passage
gates ONLY and not intended for use on
pedestrian passage gates.
• This model is intended for use in Class I, II, III
and IV vehicular slide gate applications.
• Visit LiftMaster.com to locate a professional
installing dealer in your area.
• This gate operator is compatible with MyQ
and Security+ 2.0
Access installation and technical support
guides or register this product
CSL24ULTECH
accessories.
®
Take a photo of the
1.
camera icon including
the points ( ).
Send it in by texting the
2.
photo to 71403.
®

Advertisement

loading
Need help?

Need help?

Do you have a question about the CSL24UL-MC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chamberlain CSL24UL-MC

  • Page 1 COMMERCIAL DC VEHICULAR SLIDE GATE OPERATOR INSTALLATION MANUAL EXTERNAL SAFETY EXTERNAL SAFETY DEVICES DEVICES REQUIRED. SEE SAFETY REQUIRED. SEE SAFETY SECTION FOR SECTION FOR UL 325 ENTRAPMENT UL 325 ENTRAPMENT PROTECTION PROTECTION REQUIREMENTS REQUIREMENTS • THIS PRODUCT MUST BE INSTALLED AND SERVICED IN ACCORDANCE WITH THIS MANUAL BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY.
  • Page 2 TABLE OF CONTENTS Manual Disconnect SAFETY Reset Switch Safety Symbol and Signal Word Review Operator Alarm Usage Class Remote Control UL325 Entrapment Protection Requirements ACCESSORY WIRING Safety Installation Information External Control Devices Role of Dealers, Installers, and Trained Gate System Technicians Locks Role of End Users/Home Owners Miscellaneous Wiring...
  • Page 3 SAFETY Usage Class Class I - Residential Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families. Class II - Commercial/General Access Vehicular Gate A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings...
  • Page 4 SAFETY Safety Installation Information 9. For a gate operator utilizing a Stop and/or Reset button, it must be 1. Vehicular gate systems provide convenience and security. Gate located in the line-of-sight of the gate. Activation of the reset control systems are comprised of many component parts. The gate operator is shall not cause the operator to start.
  • Page 5 SAFETY Gate Construction Information Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org. General Requirements Vehicular Horizontal Slide Gates Gates shall be constructed in accordance with the provisions The following provisions shall apply to Class I, Class II and Class III given for the appropriate gate type listed, refer to ASTM vehicular horizontal slide gates:...
  • Page 6 INTRODUCTION Carton Inventory NOT SHOWN: Documentation Packet, Chain #41 - 30 feet, Eye Bolt Kit LiftMaster Monitored Retro-Reflective Photoelectric Sensor Model LMRRUL Operator Cover 5 ft. Edge sensor kit Warning Signs (2) and Warranty Card Installation Manual Battery Tray Battery 12 Vdc 7AH (2) Key (2)
  • Page 7 INTRODUCTION Operator Specifications Usage Classification Class I, II, III, & IV Main AC Supply 120 Vac, 4 Amps (10 Amps including Accessory Outlets) OR 240 Vac, 2 Amps When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is rated 208/240/480/575 VAC, 4.8/4.2/2.1/1.7 A, 60 Hz, 1 PH System Operating Voltage 24 Vdc Transformer Run / Battery Backup...
  • Page 8 INTRODUCTION Site Preparation Check the national and local building codes BEFORE installation. Refer also to the Site Planning Safety Checklist. Conduit and Concrete Pad Safety Trench and install conduit. Before trenching, contact underground Entrapment protection devices are required to protect against any entrapment utility locating companies.
  • Page 9 INSTALLATION • To AVOID damaging gas, power or other underground utility lines, • ALWAYS wear protective gloves and eye protection when changing contact underground utility locating companies BEFORE digging the battery or working around the battery compartment. more than 18 inches (46 cm) deep. Types of Installations Standard Installation Rear Installation...
  • Page 10 INSTALLATION Step 1 Determine Location for Operator Check the national and local building codes before installation. Standard Installation 1. The gate operator should be installed near the front roller of the gate. Lay out the concrete pad. 2. Install the electrical conduit. 3.
  • Page 11 INSTALLATION Step 2 Install the Operator Attach the operator to the concrete pad with appropriate fasteners. The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between the gate and the output sprocket must be a minimum of 4 inches (10.2 cm). NOTE: An alternative to a concrete pad is to post mount the operator (refer to Accessories).
  • Page 12 INSTALLATION Step 3 Attach the Chain Standard Installation DO NOT run the operator until instructed. 1. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket in this position.
  • Page 13 INSTALLATION Rear Installation DO NOT run the operator until instructed. NOTE: This installation will require two extra idler pulleys. Make sure all exposed pinch points are guarded. Refer to Gate Construction Information on page 5. 1. Move the back pulley to the bottom hole in the operator. 2.
  • Page 14 INSTALLATION To prevent SERIOUS INJURY or DEATH from a moving gate: • ALL gate operator systems REQUIRE two independent entrapment • Entrapment protection devices MUST be located to protect in BOTH protection systems for each entrapment zone. the open and close gate cycles. •...
  • Page 15 INSTALLATION Wire Entrapment Protection Devices There are three options for wiring external entrapment protection devices depending on the specific device and how the device will function. Refer to the manual included with your entrapment protection device for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors.
  • Page 16 INSTALLATION Step 5 Earth Ground Rod To operator Use the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length.
  • Page 17 INSTALLATION All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. 240 VAC only The accessory outlet is disabled and cannot be used with the 240 Vac option.
  • Page 18 INSTALLATION AC power switch The AC Power switch on the operator will turn the incoming 120/240 Vac power ON or OFF. The operator's AC Power switch ONLY turns off AC power to the control board and DOES NOT turn off battery power. Outlet Housing Step 7 Connect Batteries Red Wire...
  • Page 19 INSTALLATION 33AH battery The batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup or solar installation. The 33AH application requires the Solar Harness Kit (Model K94-37236) and an additional battery tray (Model K10-34758-2). 1.
  • Page 20 INSTALLATION Step 8 Dual Gate Setup There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Use only the same operator models in a dual gate setup. Wired dual gate applications will have a longer battery standby time than wireless applications.
  • Page 21 INSTALLATION Wired setup DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) 22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61-305 m) Use only the same operator models in a dual gate setup. Before Wire must be rated at 30 Volt minimum digging, contact local underground utility locating companies.
  • Page 22 INSTALLATION Step 9 Install the Cover Before installing the cover, follow the instructions in the Adjustment section to adjust the limits and force. The operator cover consists of two pieces: a rear cover and a front cover. The front cover can easily be removed to access the electrical box. To access the reset switch slide the access door up.
  • Page 23 INSTALLATION Step 10 Install Warning Signs Installers MUST install the UL required warning signs. The signs MUST be installed in plain view on both sides of each gate installed. Use the fastening holes in each corner to permanently secure the sign. Place warning signs on both sides of the gate in clear view...
  • Page 24 ADJUSTMENT Limit and Force Adjustment To reduce the risk of SEVERE INJURY or DEATH: • Without a properly installed safety reversal system, persons • NEVER use force adjustments to compensate for a binding or (particularly small children) could be SERIOUSLY INJURED or sticking gate.
  • Page 25 ADJUSTMENT Fine Tune the Force Once the initial limits have been set, the REVERSAL FORCE DIAL on the control board is used for fine tuning the force where wind or environmental changes may affect the gate travel. The REVERSAL FORCE DIAL is set to minimum at the factory. Based on the length and weight of the gate it may be necessary to make additional force adjustments.
  • Page 26 PROGRAMMING Remote Controls (Not Provided) ® A total of 50 Security+ 2.0 remote controls or KPW250 keypads and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed.
  • Page 27 PROGRAMMING until the external entrapment protection device is realigned or repaired. Use LiftMaster Internet Gateway (not provided) the feature only in line of sight of the gate when no obstructions to travel To program the operator to the LiftMaster Internet Gateway: are present.
  • Page 28 OPERATION Gate Operator Setup Examples The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site requirements, including all necessary entrapment protection devices. RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns COMMERCIAL: Business site where security (gate closed) is important...
  • Page 29 OPERATION Control Board Overview 1 SET OPEN Button: The SET OPEN button sets the OPEN limit. See Adjust Limits section. section. 2 SET CLOSE Button: The SET CLOSE button sets the CLOSE limit. See Adjust Limits section. 3 MOVE GATE Buttons: The MOVE GATE buttons will either open or close the gate when the operator is in Manual Setup mode. See Adjustment section. 4 BATT FAIL: •...
  • Page 30 OPERATION Manual Disconnect Press the Reset switch to the off position “O”.  This allows the gate to be opened and closed manually.  On a dual gate application this must be done for both operators.  To resume normal operation put the switch to the on position “I”. Reset Switch Normal Operation The reset switch is located on the front of the operator and serves...
  • Page 31 ACCESSORY WIRING All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. Access control device wiring External Control Devices Access Control Device...
  • Page 32 ACCESSORY WIRING Locks CONTROL BOARD MAGLOCK Maglock (2 Terminals, N.C. and COM PROVIDED Relay contact output, Normally - closed (N.C.) output for maglocks. Relay activates prior to motor activation and during motor run. Relay is off when motor is off. Miscellaneous Wiring MAIN CONTROL BOARD Three button control station (4 Terminals...
  • Page 33 EXPANSION BOARD • To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks. Expansion Board Overview QUICK CLOSE switch: EYE/EDGE switches: OFF: No change to the gate's normal operation. Set the EYE/EDGE switches as needed to obtain the desired OPEN or CLOSE functionality.
  • Page 34 EXPANSION BOARD Auxiliary Relay 1 and 2 Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps) power sources only. Function of relay contact activation determined by switch settings. SWITCH SETTINGS AUX RELAY AUX RELAY 1...
  • Page 35 EXPANSION BOARD Wiring Accessories to the Expansion Board Refer to the chart below and the corresponding image for a description of the expansion board inputs. Wireless edge Connection for wireless edge receiver Entrapment Protection Device EYES ONLY Input: Open or Close Direction Photoelectric Sensors, Close: reverses fully, Open: reverses 4 Inputs (4 terminals total), Open or seconds Close Direction based on switch...
  • Page 36 MAINTENANCE IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: • READ AND FOLLOW ALL INSTRUCTIONS. • TEST THE GATE OPERATOR MONTHLY. The gate MUST reverse on contact with an object or reverse when an object activates the •...
  • Page 37 MAINTENANCE Batteries Batteries will degrade over time depending on temperature and usage. The operator alarm will beep 3 times with a command if the battery is low. Batteries do not perform well in extremely cold temperatures. For best performance, the batteries should be replaced every 3 years. Use only LiftMaster part 29-NP712 for replacement batteries.
  • Page 38 TROUBLESHOOTING To protect against fire and electrocution: For continued protection against fire: • DISCONNECT power (AC or solar and battery) BEFORE installing or • Replace ONLY with fuse of same type and rating. servicing operator. Diagnostic Codes NOTE: When cycling or disconnecting power (ac/dc) to the control board, it is recommended that you unplug the J15 plug. DIAGNOSTICS DISPLAY OPEN, CLOSE, &...
  • Page 39 TROUBLESHOOTING Diagnostic Codes Table Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear. External Entrapment Inherent Entrapment LiftMaster System Installed System Informational Protection...
  • Page 40 TROUBLESHOOTING Code Meaning Solution Saved Wireless edge triggered more than 3 minutes Check wired input for wiring issue or obstruction. Wireless edge loss of monitoring Check wireless edge inputs. IF an obstruction occurred, no action required. If an obstruction did NOT Wireless edge triggered occur, check inputs and wiring.
  • Page 41 TROUBLESHOOTING Control Board LEDs STATUS LEDS INPUT LEDS INPUT OFF state OPEN, CLOSE, Input inactive POWER STOP INPUT AC charger or Solar power Input active SBC INPUT available BLINK Input active on other operator or BATT Not charging expansion board CHARGING Three stage battery charging FIRE DEPT INPUT...
  • Page 42 TROUBLESHOOTING Troubleshooting Chart SYMPTOM POSSIBLE CAUSES SOLUTIONS Operator does not a. No power to control board a. Check AC and battery power run and diagnostic b. Open fuse b. Check fuses display not on. c. If on battery power only, low or dead c.
  • Page 43 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSES SOLUTIONS Gate opens, but will a. Open control active a. Check all Open inputs for an active input not close with b. Vehicle loop detector active b. Check all vehicle detector inputs for an active detector transmitter or c.
  • Page 44 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSES SOLUTIONS Expansion board a. Inoperable main board to expansion board a. Check main board to expansion board wiring. If required, replace wire function not wiring cable. controlling gate. b. Incorrect input wiring to expansion board b. Check wiring to all inputs on expansion board. c.
  • Page 45 APPENDIX Solar Panel(s) SOLAR PANELS ARE NOT PROVIDED. SEE ACCESSORIES Solar Application Requirements Solar Zones • A minimum of two 10W solar panels in series (Model SP10W12V). Solar panel recommendations are based upon the average solar radiation and the temperature effects on batteries in the given zones as shown on •...
  • Page 46 APPENDIX Solar usage guide NOTE: For additional details and specifications on solar usage, please refer to liftmaster.com. Typical System Standby Battery Current Consumption (mA) System voltage Control board with no radios programmed 2.7 mA ® One or more LiftMaster remote controls programmed +1 mA ®...
  • Page 47 APPENDIX Position MAXIMUM WIRE LENGTH The location of the panel(s) is critical to the success of the installation. In AMERICAN 20 WATTS OF 40 WATTS OF 60 WATTS OF general, the panel(s) should be mounted using the provided angle bracket WIRE PANELS PANELS...
  • Page 48 APPENDIX Wire the Batteries To “BATT DC POWER” To “BATT DC POWER” input on control board input on control board Solar panel applications require the Solar Harness Kit model K94-37236, see Accessories. White jumper wire for 33AH battery connections To Solar Panels To Solar Panels Existing Jumper Red wire for...
  • Page 49 APPENDIX SAMS Wiring with Relays Not Energized Main Board Barrier Arm Operator Exit Input Auxiliary Command Access Device Shadow Input Expansion Board POWER ONLY EYE/ EDGE EYE/ EDGE Dipswitch settings for AUX Relay 1: 1-OFF, 2-OFF, 3-ON AUX Relay 1 Dual Gate Settings NOTE: We recommend that all accessories and board configurations are set on the primary operator.
  • Page 50 APPENDIX Limit Setup with a Remote Control To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to the Programming section. Initial Limits and Force Adjustment Adjust the limits For dual gate applications the limits will have to be set for each If the limits have already been set the operator will exit the limit setting...
  • Page 51 WIRING DIAGRAM To protect against fire and electrocution: For continued protection against fire: • DISCONNECT power (AC or solar and battery) BEFORE installing or • Replace ONLY with fuse of same type and rating. servicing operator. Field Wiring Field Wiring Edge Edge Black...
  • Page 52 REPAIR PARTS Gear Reducer Pulley and Motor Pulley Timing Belt, 3M K17-36530 K16-GT2-7 Output Sprocke Battery, 7AH, 12 Vdc K15-41B17LKGH 29-NP712 APE Assembly with plastic tray, RPM board Idler Pulley with hardware with mounting hardware K75-50090 K1A6408 Gear Reducer K32-34669-3 APS Encoder, 24V K76-34697 Motor, 1/2 HP, 24 Vdc...
  • Page 53 ACCESSORIES Entrapment Protection Remote Controls LiftMaster offers a variety of LiftMaster remote controls to satisfy your LiftMaster monitored through beam photoelectric application needs. Single-button to 4-button, visor or key chain. The following sensor remote controls are compatible with operators manufactured by LiftMaster Model LMTBUL after 1993.
  • Page 54 ACCESSORIES Miscellaneous ® LiftMaster Internet Gateway Internet enabled accessory which connects your gate Post-mounting plate operator to your WiFi network and allows you to monitor For post-mounting models CSL24UL, and control gate operators and lighting accessories CSW24UL, CSW200UL, SL3000UL, ® enabled by myQ technology.
  • Page 55 WARRANTY LiftMaster 7 year residential / 5 year commercial Limited Warranty LiftMaster (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of 7 year residential installation / 5 year commercial installation from the date of purchase [and that the CSL24UL is free from defect in materials and/or workmanship for a period of 7 year residential installation / 5 year commercial installation from the date of purchase].
  • Page 56 Swing and Slide Gate Operator UL 325 and ASTM F2200 Site Planning Safety Checklist Please Print Name: Phone: Address: City/State/ZIP: Email: Satisfactory Needs Repair/Replacement Gate Safety Check — Simple steps to quickly determine if an End User’s gate operator is safe. UL 325 Standard Component: Result (Circle)
  • Page 57 GETTING STARTED WITH SWING AND SLIDE GATE OPERATORS. Always design, install and maintain safe gate access systems in accordance with UL 325 & ASTM F2200 standards. • Only install the operator on gates used for vehicular traffi c. entrapment zones are protected with a minimum of two independent †...
  • Page 60 Contact Information LiftMaster.com LiftMaster Dealer Extranet: dealer.liftmaster.com/login LiftMaster Training Academy: liftmastertraining.com 800-528-2806 Mon-Fri 5:00 am to 6:00 pm MST 300 Windsor Drive Oak Brook, IL 60523 LiftMaster.com © 2023 The Chamberlain Group LLC - All Rights Reserved 01-39381 (Rev. C)

This manual is also suitable for:

Csl24ulElite series