3-58 Diagnostic Tools
DAAD Diagnostic Messages
Configuration
signature
mismatch
Controller
communication
failure occurred
Controller
detected. NVRAM
configuration not
present
Controller firmware
needs upgrading
Controller firmware
needs upgrading
(DAAD Error 102)
Controller is
located in special
" video" slot
Controller is not
configured
Controller needs
replacing (DAAD
Error 102)
Message
Array accelerator board
configured for a different array
controller board.
Configuration signature on
array accelerator board does
not match the one stored on
the array controller board.
Controller communication
failure occurred.
EISA nonvolatile RAM does not
contain a configuration for this
controller.
Controller firmware is below
the latest recommended
version.
Controller is correct, however,
IDA firmware version should be
greater than 1.26.
Controller is installed in slot for
special video control signals. If
controller is used in this slot,
LED indicators on front panel
may not function properly.
Controller is not configured. If
controller was previously
configured and you change
drive locations, there may be
a problem with placement of
the drives. DAAD examines
each physical drive and looks
for drives that have been
moved to a different drive
bay.
IDA firmware is less than
version 0.96.
Continued
Description
Recommended Action
To recognize the array
accelerator board, run the
System Configuration Utility.
DAAD was unable to
successfully issue
commands to the
controller in this slot.
Run the System
Configuration Utility to
configure the nonvolatile
RAM.
Run Options ROMPaq to
upgrade the controller to
the latest firmware revision.
Obtain the latest firmware.
Install the controller in a
different slot and run the
System Configuration Utility
to configure the controller
and nonvolatile RAM.
Look for messages
indicating which drives
have been moved. If none
appear and drive
swapping did not occur,
run the System
Configuration Utility to
configure the controller
and nonvolatile RAM. Do
not run the System
Configuration Utility if you
believe drive swapping has
occurred.
Replace the controller as
soon as possible.