⚐ ATTENTION 1.2 Compatibility Follow instructions marked with a note carefully to prevent damage to Safera Stove Guard is compatible with property. most electrical cookers, hobs and ovens meant for household use: ѧ HINT •...
Page 3
1.3 Package content Check the product and the contents of the package before installation: Transparent front cover Power control unit Ⓒ (various models 10 x Color labels available) Cleaning pad Sensor unit Ⓐ with 2x Batteries for sen- Optional mounting User and installa- mounting bracket Ⓑ...
2. Installation - Step 1/2 Mount the Power Control Unit Ⓒ Install the power control unit Ⓒ according to the following instructions. PCU10.2-P-NEMA10-50 2-phase connection with NEMA10-50 OUT-plug. See pages 6-7. PCU10.2-PP-NEMA10-50 2-phase connection with NEMA10-50 plugs IN and OUT. See pages 8-9.
Page 5
PCU10.2.-F 2-phase connection with ixed installation. See pages 10-11. PCU6.1-F Fixed 1-phase connection. See pages 12-13.
Page 6
PCU10.2-P-NEMA10-50 - Installation 2-phase connection with NEMA10-50 OUT-plug. 195 mm 122 mm 63 mm L2/N L2/N 208-240 V MAX. 50 A 50-60 Hz ѥ WARNING Do not install the power control unit Make sure that there is no power sup- where it will be exposed to excessive ply to the cooker and the oven by re- heat: See operational ambient tem-...
Page 7
Take o fuses to the stove. Mount the power control unit Ⓒ on the wall behind Remove the the cooker or cover to access into the cabi- internal wiring. net next to the cooker. Ground wire is Connect connected to the stove the cover.
Page 8
PCU10.2-PP-NEMA10-50 - Installation 2-phase connection with NEMA10-50 plugs IN and OUT. 195 mm 122 mm 63 mm L2/N L2/N 208-240 V MAX. 50 A 50-60 Hz ѥ WARNING Do not install the power control unit Make sure that there is no power sup- where it will be exposed to excessive ply to the cooker and the oven by re- heat: See operational ambient tem-...
Page 9
Mount the power control unit Ⓒ on the wall behind the cooker or into the cabinet next to the cooker. Connect the stove plug to the power control unit (OUT) and the plug (IN) to the wall socket.
Page 10
PCU10.2-F - Installation 2-phase connection with ixed installation. 195 mm 122 mm 63 mm L2/N L2/N 208-240 V MAX. 50 A 50-60 Hz ѥ WARNING Do not install the power control unit Make sure that there is no power sup- where it will be exposed to excessive ply to the cooker and the oven by re- heat: See operational ambient tem-...
Page 11
Mount the Take o power control fuses to the unit Ⓒ on the stove. wall behind the cooker or into the cabi- net next to the cooker. Remove the cover to access internal wiring. Connect the stove plug to the Ground wire is power control connected to...
Page 12
PCU6.1-F - Installation Fixed 1-phase connection. 78 mm 60 mm 225,5 mm 42 mm 230 V MAX. 35 A MICRO DISCONNECTION ѥ WARNING Do not install the power control unit Make sure that there is no power sup- where it will be exposed to excessive ply to the cooker and the oven by re- heat: See operational ambient tem- perature on the power control unit Ⓒ.
Page 13
Optional AUX and water sensor connections. See chapter 5. L OUT...
2. Installation - Step 2/2 Mount the Sensor unit Ⓐ Install the batteries Place the batteries in the sensor unit Ⓐ which should beep twice to indicate that the wireless connection to the Pow- er Control Unit Ⓒ was successful. ⚐...
Page 15
Mounting option A: Mounting option B and C: wall-mount cooker hood -8° -8° +8° +8° max. max. 15 cm 15 cm 50 - 60 cm 55 - 65 cm (45 - 60 cm) (45 - 95 cm) 1) To install outside of the default in- 2) To install outside of the default in- stallation height 50 - 60 cm, adjust the stallation height 55 - 65 cm, adjust the...
3. Installation troubleshooting Problem Remedy Problems with checking • Retry with the same cooker plate and ensure that the the working order: the plate is set on highest power level. cooker power does not • With an induction cooker use a suitable dish so that the shut down cooker is consuming power.
4. Manual adjustment mode To enable the fast installation, the default settings of Safera Airis are suitable for the most typical installations. In case you need to install the sensor unit outside the de- fault installation dimensions or replace the cooker, sensor unit or power control unit in the original installation, you need to enter the manual adjustment mode.
Page 18
Table 2. The new alarm limit is indicated as shown in the table below: Color of the indicator light ❹ Number of beeps Alarm Limit ••• ••• ••• •• ••• • ••• •• • ••• ••• 6 (default) ••• •• •••...
Page 19
4.3 Mode 3: Manual calibration of the cooker type When the indicator light ❹ is blinking yellow-green, you may manually calibrate the cooker type from the two options: Option 1: Option 2: Cooker and oven are connected to Only cooktop is connected to the the power control unit Ⓒ.
Page 20
4.4 Mode 4: Testing and adjusting AUX-connection When the indicator light ❹ is blinking white (normal AUX-mode) or blinking red (in- versed AUX-mode, see chapter 5.1.6), you may: • Test the AUX-connection: • Toggle the AUX1 output ON/OFF by pressing the Adjustment button ❶ •...
5. Optional features 5.1 AUX-connection (optional) Safera PCU6.3 and PCU6.1 power control units Ⓒ are equipped with two auxiliary out- put signals AUX1 and AUX2 compatible with most automation and security systems. They can be used to send real-time status information of the stove guard.
Page 22
5.1.3 Example connection of one AUX-output In this case the home automation system’s logic input is pulled to ground potential when the AUX-output signal is active. Note that the maximum current pass in the optocoupler is 10 mA! +3 ... +24 VDC provided by the automation system Pull-up recommended to provide ~1mA (absolute max.
Page 23
The inversed mode will create a larger load for the connected system, because both signals will be ON most of the time. For example, this may be harder for bat- tery operated external clients. However, it will not a ect the Safera system's own battery life.
Page 24
5.2 Water leakage sensor (optional) Stove Guard can be equipped with max. four Safera water leakage sensors. The sensors are placed in the typical leak- age areas, e.g. under the dishwasher or sink. Attach the sensors Ⓕ in place. Attach the plug Ⓖ of the leakage sensor to the power control unit Ⓗ.