Table 1-6. System Messages (continued)
Message
General failure
IDE primary drive n not
found
Invalid configuration
information - please run
SETUP program
Invalid NVRAM
configuration, Resource
Re-allocated
Keyboard Controller
failure
Manufacturing mode
detected
MEMBIST failure - The
following DIMM/rank has
been disabled by BIOS:
DIMM x Rank y
Memory address line
failure at address , read
value expecting value
Memory double word logic
failure at address , read
value expecting value
Memory odd/even logic
failure at address, read
value expecting value
Memory write/read failure
at address , read value
expecting value
Memory tests terminated by
keystroke.
Causes
The operating system is unable to
carry out the command.
IDE cables are not properly seated, or
drive missing.
System has detected invalid
configuration.
System detected and corrected a
resource conflict.
Faulty keyboard controller; faulty
system board
System is in manufacturing mode.
Faulty memory module(s).
Faulty or improperly installed memory
modules.
POST memory test terminated by
pressing the spacebar.
Corrective Actions
This message is usually followed by
specific information. Note the
information and take the appropriate
action to resolve the problem.
See "Troubleshooting an Optical Drive"
on page 106.
Remove the RTCST jumper if it is
installed. See Figure 6-1 for the jumper
location.
No action is required.
See "Getting Help" on page 123.
Reboot to take the system out of
manufacturing mode.
See "Troubleshooting System Memory"
on page 103.
See "Troubleshooting System Memory"
on page 103.
Information only.